• Title/Summary/Keyword: polyglycolic acid

Search Result 31, Processing Time 0.02 seconds

Tissue Reaction to Chromic catgut, Polyglycolic acid and Nylon Sutures in the Rumen Wall of Goats (염소의 제 1위벽에 있어서 Chromic catgut, Polyglycolic acid 및 Nylon 봉합사에 대한 조직반응)

  • Ahn Keun-Seung;Nam Tchi-Chou;Cheong Chang-Kook
    • Journal of Veterinary Clinics
    • /
    • v.3 no.2
    • /
    • pp.299-307
    • /
    • 1986
  • The each rumen of six goats was incised and sutured with chromic catgut, polyglycolic acid and nylon. Tissue reaction to each suture materials was observed and comared at the 7th, 14th and 21st post-operative days. The predominent inflammatory cells around suture materials are macrophages, fibroblast and neutrophils. A few lymphocytes was infiltrated around suture materials. Infiltration of neutrophils was rapidly diminished but infiltration of macrophages, fibroblasts and lymphocytes were persisted. The overall grade of tissue reaction varid by suture materials. At the 7th post-operative days, tissue reaction to chromic catgut was most prominant and that of polyglycolic acid and nylon was moderate. At the 14th and 21st postoperative days, tissue reaction to each suture materials was not greatly different.

  • PDF

Staple Line Coverage with a Polyglycolic Acid Patch and Fibrin Glue without Pleural Abrasion after Thoracoscopic Bullectomy for Primary Spontaneous Pneumothorax

  • Hong, Ki Pyo;Kim, Do Kyun;Kang, Kyung Hoon
    • Journal of Chest Surgery
    • /
    • v.49 no.2
    • /
    • pp.85-91
    • /
    • 2016
  • Background: This study was conducted to determine the efficacy of staple line coverage using a polyglycolic acid patch and fibrin glue without pleural abrasion to prevent recurrent postoperative pneumothorax. Methods: A retrospective analysis was carried out of 116 operations performed between January 2011 and April 2013. During this period, staple lines were covered with a polyglycolic acid patch and fibrin glue in 58 cases (group A), while 58 cases underwent thoracoscopic bullectomy only (group B). Results: The median follow-up period was 33 months (range, 22 to 55 months). The duration of chest tube drainage was shorter in group A (group A $2.7{\pm}1.2day$ vs. group B $3.9{\pm}2.3day$, p=0.001). Prolonged postoperative air leakage occurred more frequently in group B than in group A (43% vs. 19%, p=0.005). The postoperative recurrence rate of pneumothorax was significantly lower in group A (8.6%) than in group B (24.1%) (p=0.043). The total cost of treatment during the follow-up period, including the cost for the treatment of postoperative recurrent pneumothorax, was not significantly different between the two groups (p=0.43). Conclusion: Without pleural abrasion, staple line coverage with a medium-sized polyglycolic acid patch and fibrin glue after thoracoscopic bullectomy for primary spontaneous pneumothorax is a useful technique that can reduce the duration of postoperative pleural drainage and the postoperative recurrence rate of pneumothorax.

Evaluation of polyglycolic acid as an animal-free biomaterial for three-dimensional culture of human endometrial cells

  • Sadegh Amiri;Zohreh Bagher;Azadeh Akbari Sene;Reza Aflatoonian;Mehdi Mehdizadeh;Peiman Broki Milan;Leila Ghazizadeh;Mahnaz Ashrafi;FatemehSadat Amjadi
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.49 no.4
    • /
    • pp.259-269
    • /
    • 2022
  • Objective: Animal-free scaffolds have emerged as a potential foundation for consistent, chemically defined, and low-cost materials. Because of its good potential for high biocompatibility with reproductive tissues and well-characterized scaffold design, we investigated whether polyglycolic acid (PGA) could be used as an animal-free scaffold instead of natural fibrin-agarose, which has been used successfully for three-dimensional human endometrial cell culture. Methods: Isolated primary endometrial cells was cultured on fibrin-agarose and PGA polymers and evaluated various design parameters, such as scaffold porosity and mean fiber diameter. Cytotoxicity, scanning electron microscopy (SEM), and immunostaining experiments were conducted to examine cell activity on fabricated scaffolds. Results: The MTT (3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide) assay and SEM results showed that endometrial cells grew and proliferated on both scaffolds. Immunostaining showed cytokeratin and vimentin expression in seeded cells after 7 days of culture. On both scaffolds, an epithelial arrangement of cultured cells was found on the top layer and stromal arrangement matrix on the bottom layer of the scaffolds. Therefore, fibrin-agarose and PGA scaffolds successfully mimicked the human endometrium in a way suitable for in vitro analysis. Conclusion: Both fibrin-agarose and PGA scaffolds could be used to simulate endometrial structures. However, because of environmental and ethical concerns and the low cost of synthetic polymers, we recommend using PGA as a synthetic polymer for scaffolding in research instead of natural biomaterials.

Clinical Impact of Polyglycolic Acid Mesh to Reduce Pancreas-Related Complications After Minimally Invasive Surgery for Gastric Cancer: A Propensity Score Matching Analysis

  • Motonari Ri;Manabu Ohashi;Rie Makuuchi;Masaru Hayami;Takeshi Sano;Souya Nunobe
    • Journal of Gastric Cancer
    • /
    • v.24 no.2
    • /
    • pp.220-230
    • /
    • 2024
  • Purpose: Prevention of pancreas-related complications after gastric cancer surgery is critical. Polyglycolic acid (PGA) mesh reduces postoperative pancreatic fistula formation following pancreatic resection. However, the clinical efficacy of PGA mesh in gastric cancer surgery has not been adequately investigated. Materials and Methods: This retrospective study compared the short-term outcomes between two groups: patients who underwent minimally invasive R0 gastrectomy for gastric cancer with the use of a PGA mesh (PGA group) and those without the use of a PGA mesh (non-PGA group) at the Cancer Institute Hospital, Tokyo, between January 2019 and May 2023. Propensity score matching (PSM) was performed to adjust for the possible confounding factors. Results: A total of 834 patients were initially included, of whom 614 (307 in each group) remained after PSM. The amylase levels in the drained abdominal fluid on postoperative days 1 and 3 were similar between the PGA and non-PGA groups. The PGA group had a significantly lower incidence of pancreas-related complications of Clavien-Dindo grade ≥2 than that in the non-PGA group (6.8% vs. 2.9%, P=0.025). In subgroup analyses, the odds ratio for pancreas-related complications appeared to be better in the PGA group than in the non-PGA group in patients with American Society of Anesthesiologists Physical Status Classification score of 2 or 3, those operated via a laparoscopic approach, and those undergoing procedures other than proximal gastrectomy. Conclusions: The use of PGA mesh significantly reduced pancreas-related complications after minimally invasive surgery for gastric cancer and might thus benefit patients at risk of such complications.

Bioactive Polyglycolic Acid (PGA) or Polylactic Acid (PLA) Polymers on Extracellular Matrix Mineralization in Osteoblast-like Mc3T3-E1 Cells

  • Cho, Young-Eun;Kim, Hye-Jin;Kim, Yong-Ha;Choi, Jae-Won;Kim, Youn-Jung;Kim, Gab-Joong;Kim, Jin-Su;Choi, Sik-Young;Kwun, In-Sook
    • Nutritional Sciences
    • /
    • v.9 no.4
    • /
    • pp.233-239
    • /
    • 2006
  • Porous matrices of bioactive polymers such as polyglycolic acid (PGA) or polylactic acid (PLA) can be used as scaffolds in bone tissue growth during bone repair process. These polymers are highly porous and serve as a template for the growth and organization of new bone tissues. We evaluated the effect of PGA and PLA polymers on osteoblastic MC3T3-E1 cell extracellular mineralization. MC3T3-E1 cells were cultured in a time-dependent manner -1, 15, 25d as appropriate - for the period of bone formation stages in one of the five culture circumstances, such as normal osteogenic differentiation medium, PGA-plated, fetal bovine serum (FBS)-plated, PGA/FBS-coplated, and PLA-plated For the evaluation of bone formation, minerals (Ca, Mg, Mn) and alkaline phosphatase activity, a marker for osteoblast differentiation, were measured Alizarin Red staining was used for the measurement of extracellular matrix Ca deposit During the culture period, PGA-plated one was reabsorbed into the medium more easily and faster than the PLA-plated one. At day 15, at the middle stage of bone formation, cellular Ca and Mg levels showed higher tendency in PGA- or PLA-plated treatments compared to non-plated control and at day 25, at the early late stage of bone formation, all three cellular Ca, Mg or Mn levels showed higher tendency as in order of PGA-related treatments and PLA-plated treatments, compared to control even without significance. Medium Ca, Mg or Mn levels didn't show any consistent tendency. Cellular ALP activity was higher in the PGA- or PLA-plated treatments compare to normal osteogenic medium treatment PGA-plated and PGA/FBS-plated treatments showed better Ca deposits than other treatments by measurement of Alizarin Red staining, although PLA-plated treatment also showed reasonable Ca deposit. The results of the present study suggest that biodegradable material, PGA and also with less extent for PLA, can be used as a biomaterial for better extracellular matrix mineralization in osteoblastic MC3T3-E1 cells.

Implantation of Fetal Hepatocytes on Biodegradable Polymer Scaffolds (생분해성 고분자 담체를 이용한 태아 간세포의 이식)

  • 곽소정;최동호;백승삼;김상수;최차용;김병수
    • KSBB Journal
    • /
    • v.19 no.3
    • /
    • pp.210-214
    • /
    • 2004
  • Whole liver transplantation, the currently available treatment of end-stage liver disease, has limitations including serious donor shortage, fatal surgical complications, risk of allograft rejection, and the requirement of life-long immunosuppression. In this study, we investigated the possibility of reconstructing liver tissues in vivo by implanting fetal hepatocytes on polymer scaffolds as a potential method to replace the current treatments. Fetal hepatocytes were freshly isolated from mice and seeded onto porous mesh scaffolds fabricated from polyglycolic acid, a biodegradable synthetic polymer. The seeded scaffolds were implanted into peritoneal cavity of athymic mice for one week. As a control, fetal hepatocytes were implanted without scaffold. One week after transplantation, liver-like tissues formed. Histological and immunohistochemical analyses indicated that the hepatocyles and liver tissue structures (bile ducts) were present in the newly formed tissues. In the control group, no transplanted hepatocytes were observed. Theses preliminary results suggest that liver tissues may be regeneration by transplanting fetal hepatocytes on polymer scaffolds.

Tissue reactions to suture materials in the oral mucosa of beagle dogs

  • Kim, Jae-Seok;Shin, Seung-Il;Herr, Yeek;Park, Joon-Bong;Kwon, Young-Hyuk;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.41 no.4
    • /
    • pp.185-191
    • /
    • 2011
  • Purpose: The objective of this study was to compare and evaluate the inflammatory responses of three widely used suture materials in the keratinized gingiva and buccal mucosa of beagle dogs. Methods: Silk, polyglycolic acid, and nylon sutures were placed within the mandibular keratinized gingiva and maxillary buccal mucosa of four male beagle dogs. Biopsies were taken 3, 7, and 14 days after suturing. Specimens were prepared with hematoxylineosin stain for evaluation under a light microscope. Results: The suture materials placed in the oral mucosa elicited more inflammatory reactions than did those placed in the keratinized gingiva. The multifilament suture materials caused more inflammatory tissue reactions than did the monofilament suture materials in the oral mucosa. Conclusions: If oral hygiene is well maintained and suture materials are placed in the keratinized gingiva, silk, nylon, and polyglycolic acid are considered to be proper suture materials for oral surgery. However, it is advisable to use monofilament suture materials if the suture site is within the oral mucosa.

Drug loaded biodegradable membranes for guided tissue regeneration (약물함유 생체분해성 차폐막의 유도조직재생에 관한 연구)

  • Kim, Dong-Kyun;Lee, Seung-Jin;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.192-209
    • /
    • 1995
  • The purpose of this study was to evaluate drug-loaded biodegradable membranes for guided tissue regeneration(GTR). The membranes were made by coating mesh of polyglycolic acid(PGA) with polylactic acid(PLA) containing 10% flurbiprofen or tetracycline. The thickness of membrane was $150{\pm}30{\mu}m$, and the pore size of surface was about $8{\mu}m$ in diameter. The release of drugs from the membrane was measured in vitro. Cytotoxity test for the membrane was performed by gingival fibroblast cell culture, and the tissue response was observed after implant of membrane into the dorsal skin of the rat for 8 wks. Ability to guided tissue regeneration of membranes were tested by measuring new bone in the calvarial defects(5mm in diameter) of the rat for 5 weeks. The amount of flurbiprofen and tetracycline released from membrane were about 30-60% during 7 days. Minimal cytotoxity was observed in the membrane except 20% drug containing membrane. In histologic finding of rat dorsal skin, many inflammatory cells were observed around e-PTFE, polyglactin 910 and PLAPGA membrane after 1 or 2 weeks. PLA-PGA membrane was perforated by connective tissue after 4 or 6 weeks, and divided as a segment at 8 weeks. In bone regeneration guiding potential test, tetracycline loaded membrane was most effective (p

  • PDF

Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

  • Kim, Young Min;Lee, Jong Hun
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.297-303
    • /
    • 2019
  • Background: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS), or various combinations of these polymers. The degradation patterns of absorbable plates made from different polymers and clinical courses of patients treated with such plates have not been fully identified. This study aimed to confirm the clinical courses of facial bone fracture patients using absorbable plates and compare the degradation patterns of the plates. Methods: A retrospective chart review was conducted for 47 cases in 46 patients who underwent open reduction and internal fixation surgery using absorbable plates to repair facial bone fractures. All surgeries used either PLA/PGA composite-based or poly-L-lactic acid (PLLA)/hydroxyapatite (HA) composite-based absorbable plates and screws. Clinical courses were confirmed and comparisons were conducted based on direct observation. Results: There were no naturally occurring foreign body reactions. Post-traumatic inflammatory responses occurred in eight patients (nine cases), in which six recovered naturally with conservative treatment. The absorbable plates were removed from two patients. PLA/PGA compositebased absorbable plates degraded into fragments with non-uniform, sharp surfaces whereas PLLA/HA composite-based absorbable plates degraded into a soft powder. Conclusion: PLA/PGA composite-based and PLLA/HA composite-based absorbable plates showed no naturally occurring foreign body reactions and showed different degradation patterns. The absorbable plate used for facial bone fracture surgery needs to be selected in consideration of its degradation patterns.