• 제목/요약/키워드: pollution monitoring

검색결과 1,025건 처리시간 0.027초

다변량분석법을 활용한 수도권지역의 대기오염측정망 평가 (Evaluation of Air Pollution Monitoring Networks in Seoul Metropolitan Area using Multivariate Analysis)

  • 최임조;조완근;신승호
    • 한국환경과학회지
    • /
    • 제25권5호
    • /
    • pp.673-681
    • /
    • 2016
  • The adequacy of urban air quality monitoring networks in the largest metropolitan city, Seoul was evaluated using multivariate analysis for $SO_2$, $NO_2$, CO, PM10, and $O_3$. Through cluster analysis for 5 air pollutants concentrations, existing monitoring stations are seen to be clustered mostly by geographical locations of the eight zones in Seoul. And the stations included in the same cluster are redundantly monitoring air pollutants exhibiting similar atmospheric behavior, thus it can be seen that they are being operated inefficiently. Because monitoring stations groups representing redudancy were different depending on measurement items and several pollutants are being measured at the same time in each air monitoring station, it is seemed to be not easy to integrate or transmigrate stations. But it may be proposed as follows : the redundant stations can be integrated or transmigrated based on ozone of which measures are increasing in recent years and alternatively the remaining pollutants other than the pollutant exhibiting similar atmospheric behavior with nearby station's can be measured. So it is considered to be able to operate air quality monitoring networks effectively and economically in order to improve air quality.

Analysis of non-point and point source pollution load in DongPieHong Ditch

  • Shan, Yu;Chen, Jun;Jin, Jie;Song, YongLian;Liu, Jun;Wu, DongBiao;Wu, Ke
    • 도시과학
    • /
    • 제8권2호
    • /
    • pp.7-12
    • /
    • 2019
  • In this study, the DongPieHong Ditch were taken as the research object, five sampling points were set to measure the COD, NH3-N,TNandTPindexes. The correlation and principal component analysis were used to judge the main pollution sources and calculate pollution contribution rate. According to the population in the basin, the load of point source pollution into the river was estimated. As a result, the load of COD, NH3-N and TP into the river was 323.04t/a, 43.8t/a and 3.9t/a, respectively. According to the statistics of the rainfall in the basin, the concentrations of COD, TP and NH3-N in the initial rainwater were measured and calculated for non-point source pollution, and the results shown that the inflow loads of COD, NH3-N and TP into the river were 34.59t/a, 0.12t/a and 0.71t/a, respectively. It was found that the main cause of the pollution in the east flash flood gully was point source pollution, and the proportions of COD, NH3-N and TP into the river were 90.33%, 99.72% and 84.61%, respectively.

한강유역 환경보전 종합계획 사업의 개요 (The Outline of Han River Basin Environmental master Plan Project)

  • 이선환
    • 기술사
    • /
    • 제15권1호
    • /
    • pp.46-50
    • /
    • 1982
  • Following rapid industrial development and urbanization in Korea, there is a need for the Government to implement effective control of pollution and to undertake specific schemes in areas where pollution of the environment is severe. In response to this need, Government of Korea prepare Han River Basin Environmental Master Plan Project for water, air, solid waste to cover environmental protection of the Han River Basin. The Project area is approximately 27,000 sq. Km extending over Seoul, Kyunggi, Kwangwon, Chungbuk Province. The total population of Master Plan Project area is approximately 11.6 million, or one-third of the total population of Korea. There are about 8,000 industries, including those located in 16 industrial complexes, in the project area. The scope of work and terms of reference are the following: (1) A Summary of existing land use and forecasts for changes in land use by the year 2,000. (2) Emission inventories for air, waste water, and solid wastes. (3) Forecasts of future population growth patterns and pollution loadings. (4) Identification of specific projects needs to reduce pollution levels and satisfy the environmental quality standards. (5) A Program of enforcement to include (i) self monitoring, and (ii) governmental inspections and surveillance. (6) A program for quality improvement and quality assurance of environmental measurements. (7) Reports summarizing all data collected analyzed during the study. (8) Conceptual design and feasibility studies, including cost estimates, for needed pollution control projects. (9) A financial plan for future detailed design and construction of public facilities, for financial incentives to industry, and for user charges for industrial use of public treatment of disposal works.

  • PDF

선태식물을 이용한 전남지역 대기오염도 평가 (Estimation of Air Pollution by Distribution of Epiphytic Bryophtes in Chonnam Area)

  • 양수인;하훈;임항선;박찬옥;홍석순;정병석
    • 한국대기환경학회지
    • /
    • 제11권2호
    • /
    • pp.137-144
    • /
    • 1995
  • The I.A.P.(Index of Atmospheric Purity) by the distribution of Bryophtes on the bark of various latifoliate tree trunks was investigated at four sites(Daeheung, Songkwang, Jeungsim, and Heunggook Temple) from April, 1991 to April, 1993. The IAP was in inverse proportion to the degree of air pollution. The I.A.P at four sites were estimated 78.2 at Daeheung temple, 61.0 at Songkwang temple, 28.3 at Jeungsim temple, and 10.3 at Heunggook temple, respectively. The distribution degree of Bryophytes in Heunggook temple progressed during the last ten years. It represents the bettrment of air quality. Bioassay by means of lichens seems to have great potential for better and less expensive ways of measuring pollution levels instead of the high cost of buying and maintaining air pollution monitoring equipment.

  • PDF

기상인자가 대기오염에 미치는 영향 (The Influence of Climatic Conditions on Air Pollution in Seoul)

  • 어수미;김광진;이규남
    • 한국환경보건학회지
    • /
    • 제23권4호
    • /
    • pp.104-114
    • /
    • 1997
  • This study was carried out to research the influence of climatic conditions including wind direction, wind speed on air pollution in Seoul. The data were obtained from the 4 sites of air pollution monitoring stations in Seoul from '95 to '96, and analyzed statistically by SAS program. The results were as follows 1. The prevailing wind directions by season in each site were as follows Nangajwa-dong were showed SE in spring, fall, winter and WNW in summer. Ssangmun-dong were showed NW in spring, fall, winter and NNE in summer. Kuro-dong were showed SW in spring, summer, ENE in fall and NW in winter. Bangi-dong were showed WNW in four seeasons. 2. The concentrations of 5 kinds(SO$_2$, Dust, NO$_2$, CO, THC) of air pollutants were relatively low in west wind. In case of O$_3$ was opposite. 3. The concentrations of 5 kinds of air pollutants were increase with decreasing wind speeds. 4. The washing effects of air pollution by rain were significant. The concentrations of 5 kinds of air pollutants were high when the humidity were 61-80%, and low as it were 0-20%. In case of O$_3$ was opposite. 5. All of air pollutants concentrations but O$_3$ were high when the UV intensity level and temperature within the range of above zero were low level.

  • PDF

해양 IT시스템용 적응형 모니터링 센서의 개발 및 성능 평가 (The Development and Performance Evaluation of Adaptive Monitoring sensor for the Marine IT System)

  • 조정환;노희정
    • 조명전기설비학회논문지
    • /
    • 제29권6호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper proposes the new adaptive gain control monitoring sensor for the marine IT system. The marine IT system sensors make it possible to conduct search missions, record climate changes, provide pollution control, study marine life, conduct survey missions, tactical surveillance, and predict natural disturbances in the ocean. In this paper, the adaptive gain control circuit which changes its parameters according to the ambient noise situation for obtaining the precise location information of marine IT system sensor is developed and analyzed. The performance characteristics for ensuring the precise location information of marine system sensor is presented and analyzed. The theoretical and experimental studies have been carried out. The presented results from the above investigation show considerably excellent performance for the monitoring of the marine system.

고효율 전기 방식용 정류기를 이용한 유류탱크의 원 방식 제어 시스템 개발 (The Development of Remote Corrosion Monitoring and Control System for Oil Tank by using the High Efficiency CP Rectifier)

  • 배정효;하태현;이현구;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.249-252
    • /
    • 2002
  • Recently, the advanced countries are using the corrosion monitoring system in a chemical plant and an oil tank in order to protect the corrosion because it leads to a big accident, pollution of soil. and lose of money Generally. the owners of the facilities adopt CP(Cathodic Protection) systems to protect the corrosion also. However, a CP system for oil tank was not considered in Korea Moreover they didn't adopted a corrosion monitoring system. In this paper, we have been developed not only the remote automatic corrosion monitoring but also the remote corrosion control system using the high efficiency CP rectifier. This results should be used to operate the CP system effectively and economically. And also it will be possible to extend the expectation life of the Oil tanks.

  • PDF

1990~1995 서울ㆍ수도권 지역의 광화학 오염현상 (Indication of Photochemical Air Pollution in the Greater Seoul Area, 1990 to 1995)

  • 김영성
    • 한국대기환경학회지
    • /
    • 제13권1호
    • /
    • pp.41-49
    • /
    • 1997
  • Status of photochemical air pollution in the Greater Seoul Area (GSA) between 1990 and 1995 was assessed in terms of frequency distributions, number of days exceeding standards, average concentration and meteorological effects. In Seoul compared with other areas in Korea, daily maximum concentration was higher but average concentration was not so high due to lower daily minimum from April to October. The top 5th percentile was high especially in summer season. Average number of days exceeding 100 ppb at monitoring stations in GSA was highest in 1994, the hottest year, but it was only 4 days a year. Mean meteorological pattern of high ozone days could be summarized as low wind speeds, high temperatures, strong solar radiation, and low precipitation. Westerlies were more frequent on high ozone days and at Pangi station located in the eastside of GSA, both number of high ozone days and average concentration were high. Effect of precursor transport on the rise of ozone concentration was, however, not consistently important on the whole in GSA.

  • PDF

자기회귀오차모형을 이용한 평택시 PM10 농도 분석 (Analysis of PM10 Concentration using Auto-Regressive Error Model at Pyeongtaek City in Korea)

  • 이훈자
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.358-366
    • /
    • 2011
  • The purpose of this study was to analyze the monthly and seasonal PM10 data using the Autoregressive Error (ARE) model at the southern part of the Gyeonggi-Do, Pyeongtaek monitoring site in Korea. In the ARE model, six meteorological variables and four pollution variables are used as the explanatory variables. The six meteorological variables are daily maximum temperature, wind speed, amount of cloud, relative humidity, rainfall, and global radiation. The four air pollution variables are sulfur dioxide ($SO_2$), nitrogen dioxide ($NO_2$), carbon monoxide (CO), and ozone ($O_3$). The result shows that monthly ARE models explained about 17~49% of the PM10 concentration. However, the ARE model could be improved if we add the more explanatory variables in the model.

Bacterial Color Response to Hexavalent Chromium, $Cr^{6+}$

  • Cheung, Ka-Hong;Gu, Ji-Dong
    • Journal of Microbiology
    • /
    • 제40권3호
    • /
    • pp.234-236
    • /
    • 2002
  • A blue pigment-producing bacterium, Vogesella indigofera, was isolated and quantified for the relationship between its synthesis of a blue pigment and exposure concentrations of $Cr^{6+}$. The concentration of $Cr^{6+}$ and the percentage of blue colonies on agar plates was negatively correlated ($r^{2}$ =-0.8683). Critical concentrations inhibiting bacterial pigment production were found to be between 100-150 $\mu\textrm{g}$ $Cr^{6+}$/ml on agar plates and 200-300 $\mu\textrm{g}$ $Cr^{6+}$/ml in liquid culture. As the blue color is characteristic and easily observable, the bacterium Vogesella indigofera may have potential applications in the detection and monitoring of environmental pollution.