• Title/Summary/Keyword: point of coincidence

Search Result 120, Processing Time 0.027 seconds

Usefulness of Panoramic Radiography in the Detection of Maxillary Sinus Pathosis (상악동 병변의 인지시 파노라마 방사선사진의 유용성)

  • Lee Eun-Sook;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.223-239
    • /
    • 1999
  • Purpose: to evaluate the usefulness of the panoramic radiography, generally used in dental clinic, for the detection of the maxillary sinus pathosis due to the inflammation and tumor, through the comparison with CT findings as the absolute standard. Materials & Methods: 150 maxillary sinuses of 75 patients with or without particular signs and symptoms and showing soft tissue lesions or destruction of maxillary sinus walls in at least one sinus in CT, were selected as subject samples, and the panoramic radiography of the same patients were interpretated by 3 dental radiologists and 3 non dental radiologist given no previous informations. Using the CT findings as the absolute standard, the diagnostic ability of panoraimc radiography in the mucosal thickening, maxillary sinus haziness, inferior wall destruction, medial wall destruction, posterolateral wall destruction and the superior wall destruction was evaluated using the ROC curve and the difference between dental radiologist group and non dental radiologist group was also evaluated. Results: 1. When dental radiologist group interpretated the destruction of inferior wall and posterolateral wall, the kappa value which shows interobserver's coincidence was above 0.75. 2. The diagnostic ability according to site of interpretation was the highest when the inferior wall was interpretated in both observer groups and there was a statistically significant difference between the dental radiologist group and non dental radiologist group in interpretating the mucosal thickening, haziness, destruction of the inferior and medial wall(p<0.05). 3. The diagnostic ability in detecting the destruction of the sinus walls was better than in soft tissue lesions in both groups and between the groups there was a statistically significant difference(p<0.05). Conclusion: When detecting the destruction of inferior and posterolateral wall of the maxillary sinus there was coincident with that of CT findings, and so it is considered that diagnostic ability of panoramic radiography is high in this point. But in interpretating the destruction of medial wall and soft tissue lesions, diagnostic ability of the panoramic radiography was relatively low and there was a significant difference between the dental radiologist group and non dental radiologist group. Therefore CT or other auxiliary diagnostic method will be necessary when evaluating thorough pathosis of maxillary sinus objectively.

  • PDF

Place Assimilation in OT

  • Lee, Sechang
    • Proceedings of the KSPS conference
    • /
    • 1996.10a
    • /
    • pp.109-116
    • /
    • 1996
  • In this paper, I would like to explore the possibility that the nature of place assimilation can be captured in terms of the OCP within the Optimality Theory (Mccarthy & Prince 1999. 1995; Prince & Smolensky 1993). In derivational models, each assimilatory process would be expressed through a different autosegmental rule. However, what any such model misses is a clear generalization that all of those processes have the effect of avoiding a configuration in which two consonantal place nodes are adjacent across a syllable boundary, as illustrated in (1):(equation omitted) In a derivational model, it is a coincidence that across languages there are changes that have the result of modifying a structure of the form (1a) into the other structure that does not have adjacent consonantal place nodes (1b). OT allows us to express this effect through a constraint given in (2) that forbids adjacent place nodes: (2) OCP(PL): Adjacent place nodes are prohibited. At this point, then, a question arises as to how consonantal and vocalic place nodes are formally distinguished in the output for the purpose of applying the OCP(PL). Besides, the OCP(PL) would affect equally complex onsets and codas as well as coda-onset clusters in languages that have them such as English. To remedy this problem, following Mccarthy (1994), I assume that the canonical markedness constraint is a prohibition defined over no more than two segments, $\alpha$ and $\beta$: that is, $^{*}\{{\alpha, {\;}{\beta{\}$ with appropriate conditions imposed on $\alpha$ and $\beta$. I propose the OCP(PL) again in the following format (3) OCP(PL) (table omitted) $\alpha$ and $\beta$ are the target and the trigger of place assimilation, respectively. The '*' is a reminder that, in this format, constraints specify negative targets or prohibited configurations. Any structure matching the specifications is in violation of this constraint. Now, in correspondence terms, the meaning of the OCP(PL) is this: the constraint is violated if a consonantal place $\alpha$ is immediately followed by a consonantal place $\bebt$ in surface. One advantage of this format is that the OCP(PL) would also be invoked in dealing with place assimilation within complex coda (e.g., sink [si(equation omitted)k]): we can make the constraint scan the consonantal clusters only, excluding any intervening vowels. Finally, the onset clusters typically do not undergo place assimilation. I propose that the onsets be protected by certain constraint which ensures that the coda, not the onset loses the place feature.

  • PDF

Analysis on the Stress of Hydraulic Cylinder for Large Vessel by Boundary Element Method (대형선박용 유압실린더에서 경제요소법을 이용한 응력해석)

  • 김옥삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.4
    • /
    • pp.423-434
    • /
    • 1995
  • It was used boundary element method(BEM) and analysed axisymmetric problem to solve hydraulic cylinder for large vessel acting uniform internal pressure(25N/m super(2)) within elastic limit. This paper was utilized the carbon steel tubes for machine structural purposed model, inner radius was 150mm and outer radius was 250mm, axial length was semi-infinite and the isoparametric element was used. The important results obtained in this study were summarized as follows. Radial, tangential and shearing stress occured the maximum stresses(48, -20 and 34MPa) at the inner radius and the minimum stresses(32, -4 and 18MPa) at the outer radius of the hydraulic cylinder for large vessel. But negative signs have meaning compressive stress and stress diminution ratio was about 0.15MPa/mm. The use of isoparametric element raised accuracy and the increment of input data lessened the error in internal point but computer run-time was increased. The double node was improved the internal solutions to settle discontinuity at corner and the double exponential formula lessened error of stress value at boundary neighborhood. And then coincidence between the analytical and exact results is found to be fairly good, showing that the proposed analytical by BEM is reliable.

  • PDF

Discontinuity Analysis Using Well Log Methods from a Borehole-PABH1 in the Pungam Sedimentary Basin (풍암퇴적분지 내 시추공 PABH1에서 불연속면에 대한 물리검층방법의 적용)

  • 김영화;장승익;김중열;현혜자
    • The Journal of Engineering Geology
    • /
    • v.8 no.3
    • /
    • pp.261-273
    • /
    • 1998
  • Multiple well log analysis technique consisting of geophysical well log and geological core log has been made to analysis the discontinuities of a test borehole-PABH1 located in Pungam sedimentary basin, Sosok, Hongchon-gun, Kangwon Province. Well log methods consist of normal resistivity log, focussed log, single point resistance log, SP log, gamma log, natural gamma log as well as acoustic televiewer log and borehole television log. Core scanning technique was used as an aid for geological core log. The analysis was made by comparing firstly the televiewer and core discontinuities, and then the results from conventional geophysical log analysis were compared to those from core log and acoustic televiewer log. Fractures deduced from the acoustic televiewer log coincide well with discontinuities shown on the core and conventional geophysical logs. Particularly close coincidence could be observed between fractures derived from acoustic televiewer and conventional geophysical log analysis. It has been noted that the geophysical logs such as, caliper, resistivity, density and high resolution gamma gamma curves are effective in delineating the fractures. For example the ratio between density and resistivity (BRD/SHN) provides also an alternative indicator for discerning the fracture condition in the study area.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

The evaluation of custo-made EWHA Breast Device(EBD) (EWHA Breast Device(EBD)의 제작 및 유용성 평가)

  • Byun Young-Sik;Oh Tae-Sung;Park Chong-Yil;Shin Hyun-Kyoh
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.33-40
    • /
    • 2005
  • Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.

  • PDF

Performance Measurement of Siemens Inveon PET Scanner for Small Animal Imaging (소동물 영상을 위한 Siemens Inveon PET 스캐너의 성능평가)

  • Yu, A-Ram;Kim, Jin-Su;Kim, Kyeong-Min;Lee, Young-Sub;Kim, Jong-Guk;Woo, Sang-Keun;Park, Ji-Ae;Kim, Hee-Joung;Cheon, Gi-Jeong
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • Inveon PET is a recently developed preclinical PET system for small animal. This study was conducted to measure the performance of Inveon PET as recommended by the NEMA NU 4-2008. We measured the spatial resolution, the sensitivity, the scatter fraction and the NECR using a F-18 source. A 3.432 ns coincidence window was used. A $1\;mm^3$ sized F-18 point source was used for the measurement of spatial resolution within an energy window of 350~625 keV. PET acquisition was performed to obtain the spatial resolution from the center to the 5 cm offset toward the edge of the transverse FOV. Sensitivity, scatter fraction, and NECR were measured within an energy window of 350~750 keV. For measuring the sensitivity, a F-18 line source (length: 12.7 cm) was used with concentric 5 aluminum tubes. For the acquisition of the scatter fraction and the NECR, two NEMA scatter phantoms (rat: 50 mm in diameter, 150 mm in length; mouse: 25 mm in diameter, 70 mm in length) were used and the data for 14 half-lives (25.6 hr) was obtained using the F-18 line source (rat: 316 MBq, mouse: 206 MBq). The spatial resolution of the F-18 point source was 1.53, 1.50 and 2.33 mm in the radial, tangential and axial directions, respectively. The volumetric resolution was $5.43\;mm^3$ in the center. The absolute sensitivity was 6.61%. The peak NECR was 486 kcps @121 MBq (rat phantom), and 1056 kcps @128 MBq (mouse phantom). The values of the scatter fraction were 20.59% and 7.93% in the rat and mouse phantoms, respectively. The performances of the Inveon animal PET scanner were measured in this study. This scanner will be useful for animal imaging.

The Alignment Evaluation for Patient Positioning System(PPS) of Gamma Knife PerfexionTM (감마나이프 퍼펙션의 자동환자이송장치에 대한 정렬됨 평가)

  • Jin, Seong Jin;Kim, Gyeong Rip;Hur, Beong Ik
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.203-209
    • /
    • 2020
  • The purpose of this study is to assess the mechanical stability and alignment of the patient positioning system (PPS) of Leksell Gamma Knife Perfexion(LGK PFX). The alignment of the PPS of the LGK PFX was evaluated through measurements of the deviation of the coincidence of the Radiological Focus Point(RFP) and the PPS Calibration Center Point(CCP) applying different weights on the couch(0, 50, 60, 70, 80, and 90 kg). In measurements, a service diode test tool with three diode detectors being used biannually at the time of the routine preventive maintenance was used. The test conducted with varying weights on the PPS using the service diode test tool measured the radial deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. In order to evaluate the alignment of the PPS, the radial deviations of the correspondence of the radiation focus and the LGK calibration center point of multiple beams were averaged using the calibrated service diode test tool at three university hospitals in Busan and Gyeongnam. Looking at the center diode for all collimators 4, 8, and 16 mm without weight on the PPS, and examining the short and long diodes for the 4 mm collimator, the means of the validation difference, i.e., the radial deviation for the setting of 4, 8, and 16 mm collimators for the center diode were respectively measured to 0.058 ± 0.023, 0.079 ± 0.023, and 0.097 ± 0.049 mm, and when the 4 mm collimator was applied to the center diode, the short diode, and the long diode, the average of the radial deviation was respectively 0.058 ± 0.023, 0.078 ± 0.01 and 0.070 ± 0.023 mm. The average of the radial deviations when irradiating 8 and 16 mm collimators on short and long diodes without weight are measured to 0.07 ± 0.003(8 mm sd), 0.153 ± 0.002 mm(16 mm sd) and 0.031 ± 0.014(8 mm ld), 0.175 ± 0.01 mm(16 mm ld) respectively. When various weights of 50 to 90 kg are placed on the PPS, the average of radial deviation when irradiated to the center diode for 4, 8, and 16 mm is 0.061 ± 0.041 to 0.075 ± 0.015, 0.023 ± 0.004 to 0.034 ± 0.003, and 0.158 ± 0.08 to 0.17 ± 0.043 mm, respectively. In addition, in the same situation, when the short diode for 4, 8, and 16 mm was irradiated, the averages of radial deviations were 0.063 ± 0.024 to 0.07 ± 0.017, 0.037 ± 0.006 to 0.059 ± 0.001, and 0.154 ± 0.03 to 0.165 ± 0.07 mm, respectively. In addition, when irradiated on long diode for 4, 8, and 16 mm, the averages of radial deviations were measured to be 0.102 ± 0.029 to 0.124 ± 0.036, 0.035 ± 0.004 to 0.054 ± 0.02, and 0.183 ± 0.092 to 0.202 ± 0.012 mm, respectively. It was confirmed that all the verification results performed were in accordance with the manufacturer's allowable deviation criteria. It was found that weight dependence was negligible as a result of measuring the alignment according to various weights placed on the PPS that mimics the actual treatment environment. In particular, no further adjustment or recalibration of the PPS was required during the verification. It has been confirmed that the verification test of the PPS according to various weights is suitable for normal Quality Assurance of LGK PFX.

Ahn Jeong-Bok's idea of country village community (18세기 향촌사회와 유교공동체 - 순암 안정복을 중심으로 -)

  • Kim, Bo-kyoung
    • (The)Study of the Eastern Classic
    • /
    • no.35
    • /
    • pp.415-445
    • /
    • 2009
  • A well-known historian, Ahn Jeong-Bok(Sun-Am, 1712~1791) was an expert on the country village community. He was a scholar of the "Nam-In" group, who was excluded from the corridors of power in those days. He kept on the move in various parts of country villages from his childhood. After settling down in Deok-Gok, Kwang-Ju, he stayed in the place devoting himself to the self-culture and the literary works. By his surrounding of environment, he had an academic interest in a concrete science rather than metaphysics and country villages rather than the central city. He considered the country villages as the link holding between a family and a country and had the conception of a confucianist community based on country villages, emphasizing the practice of confucianist virtues in everyday life. First of all, his confucianist community was the community based on country villages. He thought that the enlightenment was a matter of great importance for solving problems in country villages. As a solution to those problems, he suggested Hyang-Yak, the self-governed regulations of country villages. In his own village he made the self-governed rules Dong-Yak. When he was a provincial governer of Mok-Cheon, he put Hyang-Yak, the self-governed regulations of country villages in operation. It aimed for a kind of gentry-centric country village community. But Hyang-Yak was the regulations based on the agreement with each other, stressed the regard on the popular mind and the setting the pace of the gentry, and aimed for the harmony and order in a community through the practice of moral virtues in daily life. On the other hand, he had a conception of a country village's academic community. He thought of the development of educational intuitions as a pressing need of the enlightenment of country village. With young people he read confucianist books with comments in a village school, Seo-Jae. In his seventies, he made and put the self-regulations for academic community, Hak-Yak, in operations. It is considered that Hak-Yak was an example of his idea of academic community and his point of view on learning, which emphasized on the coincidence with reading and practice.

Commissioning Experience of Tri-Cobalt-60 MRI-guided Radiation Therapy System (자기공명영상유도 Co-60 기반 방사선치료기기의 커미셔닝 경험)

  • Park, Jong Min;Park, So-Yeon;Wu, Hong-Gyun;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.193-200
    • /
    • 2015
  • The aim of this study is to present commissioning results of the ViewRay system. We verified safety functions of the ViewRay system. For imaging system, we acquired signal to noise ratio (SNR) and image uniformity. In addition, we checked spatial integrity of the image. Couch movement accuracy and coincidence of isocenters (radiation therapy system, imaging system and virtual isocneter) was verified. Accuracy of MLC positioing was checked. We performed reference dosimetry according to American Association of Physicists in Medicine (AAPM) Task Group 51 (TG-51) in water phantom for head 1 and 3. The deviations between measurements and calculation of percent depth dose (PDD) and output factor were evaluated. Finally, we performed gamma evaluations with a total of 8 IMRT plans as an end-to-end (E2E) test of the system. Every safety system of ViewRay operated properly. The values of SNR and Uniformity met the tolerance level. Every point within 10 cm and 17.5 cm radii about the isocenter showed deviations less than 1 mm and 2 mm, respectively. The average couch movement errors in transverse (x), longitudinal (y) and vertical (z) directions were 0.2 mm, 0.1 mm and 0.2 mm, respectively. The deviations between radiation isocenter and virtual isocenter in x, y and z directions were 0 mm, 0 mm and 0.3 mm, respectively. Those between virtual isocenter and imaging isocenter were 0.6 mm, 0.5 mm and 0.2 mm, respectively. The average MLC positioning errors were less than 0.6 mm. The deviations of output, PDDs between mesured vs. BJR supplement 25, PDDs between measured and calculated and output factors of each head were less than 0.5%, 1%, 1% and 2%, respectively. For E2E test, average gamma passing rate with 3%/3 mm criterion was $99.9%{\pm}0.1%$.