References
- Stam MK, van Vulpen M, Barendrecht MM, et al: Kidney motion during free breathing and breath hold for MR-guided radiotherapy. Phys Med Biol 58(7):2235-2245 (2013) https://doi.org/10.1088/0031-9155/58/7/2235
- Seierstad T, Hole KH, Saelen E, et al: MR-guided simultaneous integrated boost in preoperative radiotherapy of locally advanced rectal cancer following neoadjuvant chemotherapy. Radiother Oncol 93(2):279-284 (2009) https://doi.org/10.1016/j.radonc.2009.08.046
- Mutic S, Dempsey JF: The ViewRay system: magnetic resonance-guided and controlled radiotherapy. Semin Radiat Oncol 24(3):196-199 (2014) https://doi.org/10.1016/j.semradonc.2014.02.008
- Wooten HO, Green O, Yang M, et al: Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a Co-60 Magnetic Resonance Image Guidance Radiation Therapy System. Int J Radiat Oncol Biol Phys 92(4):771-778 (2015) https://doi.org/10.1016/j.ijrobp.2015.02.057
- Wooten HO, Rodriguez V, Green O, et al: Benchmark IMRT evaluation of a Co-60 MRI-guided radiation therapy system. Radiother Oncol 114(3):402-405 (2015) https://doi.org/10.1016/j.radonc.2015.01.015
- Kishan AU, Cao M, Wang PC, et al: Feasibility of magnetic resonance imaging-guided liver stereotactic body radiation therapy: A comparison between modulated tri-cobalt-60 teletherapy and linear accelerator-based intensity modulated radiation therapy. Pract Radiat Oncol 5(5):330-337 (2015) https://doi.org/10.1016/j.prro.2015.02.014
- Rajiv L, Gopi K, Sathish K: Acceptance Test Procedure for MRIdian System. ViewRay Inc., Cleveland, OH (2015)
- Attix FH: Introduction to radiological physics and radiation dosimetry. 1st ed, Wiley, New York, NY (1986)
- Day M, EGA A: Central axis depth dose data for use in radiotherapy: A survey of depth doses and related data measured in water or equivalent media. Brit J Radiol Suppl 17:1-147 (1983)
- Ezzell GA, Burmeister JW, Dogan N, et al: IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 36(11): 5359-5373 (2009) https://doi.org/10.1118/1.3238104
- Almond PR, Biggs PJ, Coursey BM, et al: AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med Phys 26(9):1847-1870 (1999) https://doi.org/10.1118/1.598691
- Klein EE, Hanley J, Bayouth J, et al: Task Group 142 report: quality assurance of medical accelerators. Med Phys 36(9):4197-4212 (2009) https://doi.org/10.1118/1.3190392
- Kutcher GJ, Coia L, Gillin M, et al: Comprehensive QA for radiation oncology: report of AAPM Radiation Therapy Committee Task Group 40. Med Phys 21(4):581-618 (1994) https://doi.org/10.1118/1.597316
Cited by
- Treatment Plan Delivery Accuracy of the ViewRay System in Two-Headed Mode vol.27, pp.3, 2015, https://doi.org/10.14316/pmp.2016.27.3.169
- Quality of tri-Co-60 MR-IGRT treatment plans in comparison with VMAT treatment plans for spine SABR vol.90, pp.1070, 2017, https://doi.org/10.1259/bjr.20160652
- MRI-based radiotherapy planning method using rigid image registration technique combined with outer body correction scheme: a feasibility study vol.8, pp.33, 2015, https://doi.org/10.18632/oncotarget.17672
- Development of patient-controlled respiratory gating system based on visual guidance for magnetic-resonance image-guided radiation therapy vol.44, pp.9, 2015, https://doi.org/10.1002/mp.12447
- Treatment plan comparison between Tri-Co-60 magnetic-resonance image-guided radiation therapy and volumetric modulated arc therapy for prostate cancer vol.8, pp.53, 2017, https://doi.org/10.18632/oncotarget.20039
- Implementation of AAPM's TG-51 Protocol on Co-60 MRI-Guided Radiation Therapy System vol.28, pp.4, 2017, https://doi.org/10.14316/pmp.2017.28.4.190
- Air-electron stream interactions during magnetic resonance IGRT : Skin irradiation outside the treatment field during accelerated partial breast irradiation vol.194, pp.1, 2015, https://doi.org/10.1007/s00066-017-1212-z
- Lung density change after SABR: A comparative study between tri-Co-60 magnetic resonance-guided system and linear accelerator vol.13, pp.4, 2015, https://doi.org/10.1371/journal.pone.0195196
- Suitability of EBT3 GafChromic film for quality assurance in MR-guided radiotherapy at 0.35 T with and without real-time MR imaging vol.63, pp.16, 2015, https://doi.org/10.1088/1361-6560/aad58d
- Efficient Verification of X-ray Target Replacement for the C-series High Energy Linear Accelerator vol.29, pp.3, 2015, https://doi.org/10.14316/pmp.2018.29.3.92
- Low Magnetic Field MRI Visibility of Rubber-Based Markers vol.30, pp.4, 2015, https://doi.org/10.14316/pmp.2019.30.4.89
- Monte Carlo modeling of a 60 Co MRI-guided radiotherapy system on Geant4 and experimental verification of dose calculation under a magnetic field of 0.35 T vol.60, pp.1, 2015, https://doi.org/10.1093/jrr/rry087
- Characterizing MR Imaging isocenter variation in MRgRT vol.6, pp.3, 2015, https://doi.org/10.1088/2057-1976/ab7bc6
- Machine QA for the Elekta Unity system: A Report from the Elekta MR‐linac consortium vol.48, pp.5, 2015, https://doi.org/10.1002/mp.14764
- ESTRO-ACROP recommendations on the clinical implementation of hybrid MR-linac systems in radiation oncology vol.159, pp.None, 2015, https://doi.org/10.1016/j.radonc.2021.03.025
- Performance of a newly designed end‐to‐end phantom compatible with magnetic resonance‐guided radiotherapy systems vol.48, pp.11, 2015, https://doi.org/10.1002/mp.15153