• Title/Summary/Keyword: planar mode

Search Result 252, Processing Time 0.029 seconds

Dispersion Analysis of Higher-Order Modes for Planar Transmission Lines Using the 2-Dimensional Finite-Difference Time-Domain Method (2차원 유한차분-시간영역 방법을 이용한 평면형 전송선로의 고차 모드 분산 특성 해석)

  • 전중창;박위상
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.6
    • /
    • pp.847-854
    • /
    • 1999
  • In this paper, we have analysed frequency-dispersion characteristics of higher-order modes for uniform planar transmission lines, using the 2-dimensional finite-difference time-domain method. The method presented in this paper uses both informations of amplitude and phase of the electromagnetic spectrum to determine resonant frequencies, while methods previously reported use the magnitude only. This algorithm is very useful when a resonant mode has a relatively small magnitude, where the identification of the resonant mode is quite difficult. Numerical results show that a strip line supports few higher-order modes within the frequency range of 20 GHz, but there occur many higher-order modes in the structure of grounded coplanar waveguide, where resonant frequencies of the first higher-order mode is very close to those of the fundamental mode and there occur lots of very adjacent higher-order modes. As in this example, for the analysis of planar transmission lines which support many resonant modes very close each other, the method presented in this paper can be applied very efficiently.

  • PDF

Conducting Polymer Material Characterization Using High Frequency Planar Transmission Line Measurement

  • Cho, Young-Seek;Franklin, Rhonda R.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.5
    • /
    • pp.237-240
    • /
    • 2012
  • A conducting polymer, poly 3-hexylthiophene (P3HT) is characterized with the metal-insulator-semiconductor (MIS) measurement method and the high frequency planar circuit method. From the MIS measurement method, the relative dielectric constant of the P3HT film is estimated to be 4.4. For the high frequency planar circuit method, a coplanar waveguide is fabricated on the P3HT film. When applying +20 V to the CPW on P3HT film, the P3HT film is in accumulation mode and becomes lossy. The CPW on P3HT film is 1.5 dB lossier than the CPW on $SiO_2$ film without P3HT film at 50 GHz.

Non-Planar Non-Linear Vibration Phenomenon on the One to One Resonance of the Circular Cantilever Beam (원형 외팔보의 일대일 공진에서의 비평면 비선형 진동현상)

  • Park Chul-Hui;Cho Chongdu;Kim Myoung-Gu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.171-178
    • /
    • 2006
  • Experimental and theoretical study of the non-planar response motions of a circular cantilever beam subject to base harmonic excitation has been presented in this paper work. Theoretical research is conducted using two non-linear coupled integral-differential equations of motion. These equations contain cubic linearities due do curvature term and inertial term. A combination of the Galerkin procedure and the method of multiple scales are used to construct a first-order uniform expansion for the case of one-to-one resonance. The results show that the non-linear geometric terms are very important for the low-frequency modes of the first and second mode. The non-linear inertia terms are also important for the high-frequency modes. We present the quantitative and qualitative results for non-planar motions of the dynamic behavior.

Fabrication and Packaging of Planar Waveguide Brags Grating (평판도파로 브래그격자 제조 및 접속)

  • 한준모;최준석;문형명;임기건;이형종;최두선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.141-144
    • /
    • 2002
  • Computer code was developed to design waveguide gratings based on coupled-mode equations and the transfer matrix formalism. The experimental set-up has been constructed for inscribing Bragg gratings in planar waveguides with a phase mask and uv laser beam, which enables alignment and packaging of grating devices as well as in-situ performance measurements. Bragg grating has been fabricated on silica planar waveguides with 0.75% Germanium concentration and its transmittance spectrum was measured to have 95% reflectance at the peak wavelength. Optical losses as the function of the misalignment were measured and their usage is described.

  • PDF

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

Characteristics of Roadside Cut-Slopes Failures along the 46th National Highway (남양주-춘천(국도 46 호선)간 도로절개면 붕괴 특성 고찰)

  • 구호본;정의진;박성욱
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.11a
    • /
    • pp.527-534
    • /
    • 2000
  • 136 cut slopes which extends from Namyangju to Chunchon city along the 46th national highway were investigated to analyze the influence factors affecting slope instability. Geologic and geotechnical conditions were examined and the detailed investigation were carried out for fifty five failed slopes. failure mode (wedge failure, planar failure, circular failure, sheet eroison and rock falls) are examined with respect to slope inclination, rock type, weathering grade and discontinuity patterns. It is suggested that the failure modes and their dimensions have relations to the morphology and geologic conditions of the slopes. Wedge failure has highest is the most frequent failure mode and falls, sheet erosions, planar failures and circular in descending order of failure percentage. Wedge failure is most dominant failure type over all lithology except quartzite formation. In slopes of well foliated and banded gneiss, failure ratio of wedge is up to 50% ca. Failure ratio(number of rock fall/number of total failure) of rock fall increases with increase fo slope inclinations and decrease of weathering grade. Dimension analyses of failed slopes shows wedge and circular failure has higher value of D/L and D/H than planar failure and sheet erosion.

  • PDF

High-sensitivity temperature sensor using the side polished single mode fiber and polymer planar waveguide coupler (측면연마된 단일모드 광섬유와 폴리머 평면도파로 결합기를 이용한 고감도 온도센서)

  • Jeong, Ung-Gyu;Kim, Sang-U;Kim, Gwang-Taek;Kim, Eung-Su;Yu, Yun-Sik;Gang, Sin-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.1
    • /
    • pp.39-46
    • /
    • 2002
  • High-senstivity temperature sensor based on the wavelength selectivity of single mode fiber-to-planar waveguide coupler, was demonstrated. The resonant wavelength of the coupler was shifted with large rate of -3.43nm/$^{\circ}C$ owing to good thermo-optic effects of polymer planar waveguide. The device design technique to reduce the polarization dependent properties and increase the temperature sensitivity was presented.

Nonlinear guided-wave properties in planar waveguides with two nonlinear bounding thin films (비선형 박막으로 둘러싸인 평면 광도파로에서의 비선형 도파광 특성)

  • 정종술;송석호;이일항
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.136-141
    • /
    • 1996
  • We present a novel description of TE nonlinear guided waves in planar waveguides with two nonlinear bounding thin films. The nonlinear dispersion relations of the nonlinear waveguides are obtained by adopting the nonlinear transfer matrix. The optical properties obtained from these equations include: the power dependence of mode indices, the transition of the field maximum location, and the power distribution. The planar waveguide with self-focusing nonlinear layers shows the optical bistability of power-dependent mode indices, and the critical powers for the optical bistability increase with decreasing thickness of the nonlinear layers. The power distributions display the optical bistabilities, similar to those of nonlinear Fabry-Perot etalon.

  • PDF

Similarity Analysis for the Dispersion of Spiraling Modes on Metallic Nanowire to a Planar Thin Metal Layer

  • Lee, Dong-Jin;Park, Se-Geun;Lee, Seung-Gol;O, Beom-Hoan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.538-542
    • /
    • 2013
  • We propose a simple model to elucidate the dispersion behavior of spiraling modes on silver nanowire by finding correspondence parameters and building a simple equivalent relationship with the planar insulator-metal-insulator geometry. The characteristics approximated for the proposed structure are compared with the results from an exact solution obtained by solving Maxwell's equation in cylindrical coordinates. The effective refractive index for our proposed equivalent model is in good agreement with that for the exact solution in the 400-2000 nm wavelength range. In particular, when the radius of the silver nanowire is 100 nm, the calculated index shows typical improvements; the average percentage error for the real part of the effective refractive index is reduced to only 5% for the $0^{th}$ order mode (11.9% in previous results) and 1.5% for the $1^{st}$ order mode (24.8% in previous results) in the 400-800 nm wavelength range. This equivalent model approach is expected to provide further insight into understanding the important behavior of nanowire waveguides.

A Three-Dimensional Calculation of the Reactor Impedance for Planar-Type Cylindrical Inductively Coupled Plasma Sources

  • Kwon, Deuk-Chul;Yoon, Nam-Sik
    • Applied Science and Convergence Technology
    • /
    • v.24 no.6
    • /
    • pp.237-241
    • /
    • 2015
  • The reactor impedance is calculated for a planar-type cylindrical inductively coupled plasma source by expanding the electromagnetic fields into their Fourier-Bessel series forms including the three-dimensional shape of the antenna. The mode excitation method is utilized to determine the electromagnetic fields based on a Poynting theorem-like relationship. From the obtained electromagnetic fields, a tractable form of the reactor impedance is obtained as a function of various plasma and geometrical parameters and applied to carry out a parametric study.