• Title/Summary/Keyword: pixel density

Search Result 133, Processing Time 0.026 seconds

A Study on Aerial Perspective on Painterly Rendering (회화적 렌더링에서의 대기원근법의 표현에 관한 연구)

  • Jang, Jae-Ni;Ryoo, Seung-Taek;Seo, Sang-Hyun;Lee, Ho-Chang;Yoon, Kyung-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.10
    • /
    • pp.1474-1486
    • /
    • 2010
  • In this paper, we propose an algorithm which represents the distance depiction technique of real painting that named "Aerial Perspective" in painterly rendering. It is a painting technique that depicts the attenuations of light in the atmosphere, and the scattering effect is changed by the distance, altitude and density of atmospheres. For the reflection of these natures, we use the depth information corresponding to an input image and user-defined parameters, so that user changes the effect level. We calculate the distance and altitude of every pixel with the depth information and parameters about shot information, and control the scattering effects by expression parameters. Additionally, we accentuate the occluding edges detected by the depth information to clarify the sense of distance between fore and back-ground. We apply our algorithm on various landscape scenes, and generate the distance-emphasized results compared to existing works.

Realization of a High Precision Inspection System for the SOP Types of ICs (SOP형 IC의 고 정밀 외관검사 시스템 구현)

  • Tae Hyo Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.5 no.2
    • /
    • pp.165-171
    • /
    • 2004
  • Owing to small sizes and high density to the semiconductor It, it is difficult to discriminate the defects of ICs by human eyes. High precision inspection system with computer vision is essentially established for the manufacturing process due to the variety of defective parts. Especially it is difficult to implement the algorithm for the coplanarity of IC leads. Therefore in this paper, the inspection system which can detect the defects of the SOP types of ICs having 1cm${\times}$0.5cm of the chip size is implemented and evaluated it's performance. In order to optimally detect various items, some principles of geometry are theoretically presented , length measurement, pitch measurement, angle measurement, brightness of image and correcton of position. The interface circuit is designed for implementation of inspection system and connected the HANDLER. In the result, the system could detect two ICs' defects per second and confirmed the resolution of 20$\mu$m per pixel.

  • PDF

Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks (원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발)

  • Zhuang, Li;Yeom, Sun;Shin, Hyu-Soung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.9
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray computed tomography (CT) is very useful for the quantitative evaluation of internal structures, particularly defects in rock samples, such as pores and fractures. In situ CT allows 3D imaging of a sample subjected to various external treatments such as loading and therefore enables observation of changes that occur during the loading process. We reviewed state-of-the-art of in situ CT applications for geomaterials. Two triaxial cells made using relatively low density but high strength materials were developed aimed at in situ CT scanning during hydro-mechanical laboratory testing of rocks. Preliminary results for in situ CT imaging of granite and sandstone samples with diameters ranging from 25 mm to 50 mm show a resolution range of 34~105 ㎛ per pixel pitch, indicating the feasibility of in situ CT observations for internal structural changes in rocks at the micrometer scale. Potassium iodide solution was found to improve the image contrast, and can be used as an injection fluid for hydro-mechanical testing combined with in situ CT scanning.

A Study on the Circuit Design Methodology and Performance Evaluation for Hybrid Gate Driver (하이브리드 게이트 드라이버를 위한 회로 디자인 방법과 성능 평가에 관한 연구)

  • Cho, Geunho
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.381-387
    • /
    • 2021
  • As Head-Mounted Displays(HMDs), which are mainly used to maximize realism in games and videos, have experienced increased demand and expanded scope of use in education and training, there is growing interest in methods to enhance the performance of conventional HMDs. In this study, a methodology to utilize Carbon NanoTubes(CNTs) to improve the performance of gate drivers that send control signals to each pixel circuit of the HMD is discussed. This paper proposes a new circuit design method that replaces the transistors constituting the buffer part of the conventional gate driver with transistors incorporating CNTs and compare the performance of the suggested gate drive with that of a gate driver comprising only conventional transistors via simulations. According to the simulation results, by including CNTs in the gate driver, the output voltage can be increased by approximately 0.3V compared to the conventional gate driver high voltage(1.1V) at a speed of 12.5 GHz and the gate width also can be reduced by up to 20 times.

Investigation of Scatter and Septal Penetration in I-131 Imaging Using GATE Simulation (GATE 시뮬레이션을 이용한 I-131 영상의 산란 및 격벽통과 보정방법 연구)

  • Jung, Ji-Young;Kim, Hee-Joung;Yu, A-Ram;Cho, Hyo-Min;Lee, Chang-Lae;Park, Hye-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.72-79
    • /
    • 2009
  • Scatter correction for I-131 plays a very important role to improve image quality and quantitation. I-131 has multiple and higher energy gamma-ray emissions. Image quality and quantitative accuracy in I-131 imaging are degraded by object scatter as well as scatter and septal penetration in the collimator. The purpose of this study was to estimate scatter and septal penetration and investigate two scatter correction methods using Monte Carlo simulation. The gamma camera system simulated in this study was a FORTE system (Phillips, Nederland) with high energy, general-purpose, parallel hole collimator. We simulated for two types of high energy collimators. One is composed of lead, and the other is composed of artificially high Z number and high density. We simulated energy spectrum using a point source in air. We estimated both full width at half maximum (FWHM) and full width at tenth maximum (FWTM) using line spread function (LSF) in cylindrical water phantom. We applied two scatter correction methods, triple energy window scatter correction (TEW) and extended triple energy window scatter correction (ETEW). The TEW method is a pixel-by pixel based correction which is easy to implement clinically. The ETEW is a modification of the TEW which corrects for scatter by using abutted scatter rejection window, which can overestimate or the underestimate scatter. The both FWHM and FWTM were estimated as 41.2 mm and 206.5 mm for lead collimator, respectively. The FWHM and FWTM were estimated as 27.3 mm and 45.6 mm for artificially high Z and high density collimator, respectively. ETEW showed that the estimation of scatter components was close to the true scatter components. In conclusion, correction for septal penetration and scatter is important to improve image quality and quantitative accuracy in I-131 imaging. The ETEW method in scatter correction appeared to be useful in I-131 imaging.

  • PDF

Efficient of Hepatobiliary Scintigraphy both Decubitus Position in Biliary Leakage Patients (간담도 스캔 시 담즙 누출(Biliary Leakage)환자에서의 양측와위 자세(Both Decubitus Position)의 유용성)

  • Bahn, Young-Kag;Roh, Dong-Ook;Kang, Chun-Koo;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.229-234
    • /
    • 2008
  • Hepatobiliary scintigraphy is very sensitivity of hepatic cell and gallbladder, biliary track atresia and biliary leakage. however, Hepatobiliary scan of biliary leakage diagnosis was separated determine biliary leakage and bowl drainage bile-juice. The object of this study will determine biliary leakage and bowl drainage bile-juice to hepatobiliary scintigraphy both decubitus position in bile leakage patients. Material & Methode: 31 patients (meal 14, Femeal 17), $51.1{\pm}14.4$ years. dynamic scan acquisition 60 farme for 60 minute on supine position. and delay scan was 2 hrs, 4 hrs, 24 hrs for 5 minute on supine, both decubitus position. Both decubitus position scan was kept for 5 minutes. Efficient of Hepatobiliary Scintigraphy both decubitus position in bile leakage patients was compared leakage size, density, image of supine position and both decubitus position. Results: 23 patients for 31 bile leakage patients was checked up function image or delay image, and 8 patients was checked up bile leakage on both decubitus. anatomical leakage location was supine position very well, but both decubitus position was separated bile leakage and moving bile-juice in bowl. also, uptake (counts/pixel) average of roi and bkg was supine 5.02, left decubitus 2.08, right decubitus 2.68. No. pixels of supine ROI counted 1.91 times than left decubitus, 1.05 times than right decubitus. Conclusion: 31 patient both decubitus position, but decubitus position was separated bile juice movement in bowl leakage location. also, It was compared ROI/BKG ratio and ROI No. pixels of supine, both decubitus in 38.5% patients. And No. pixels of supine position was large 19%, 5% than left decubitus, right decubitus, And density was in low 60%, 50% than left decubitus, right decubitus. It was mean bile leakage of ROI. so, If Hepatobiliary Scintigraphy was additional both decubitus position scan in bile leakage patients, this study will be more valuable in diagnosis of bile leakage.

  • PDF

The Region-of-Interest Based Pixel Domain Distributed Video Coding With Low Decoding Complexity (관심 영역 기반의 픽셀 도메인 분산 비디오 부호)

  • Jung, Chun-Sung;Kim, Ung-Hwan;Jun, Dong-San;Park, Hyun-Wook;Ha, Jeong-Seok
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.79-89
    • /
    • 2010
  • Recently, distributed video coding (DVC) has been actively studied for low complexity video encoder. The complexity of the encoder in DVC is much simpler than that of traditional video coding schemes such as H.264/AVC, but the complexity of the decoder in DVC increases. In this paper, we propose the Region-Of-Interest (ROI) based DVC with low decoding complexity. The proposed scheme uses the ROI, the region the motion of objects is quickly moving as the input of the Wyner-Ziv (WZ) encoder instead of the whole WZ frame. In this case, the complexity of encoder and decoder is reduced, and the bite rate decreases. Experimental results show that the proposed scheme obtain 0.95 dB as the maximum PSNR gain in Hall Monitor sequence and 1.87 dB in Salesman sequence. Moreover, the complexity of encoder and decoder in the proposed scheme is significantly reduced by 73.7% and 63.3% over the traditional DVC scheme, respectively. In addition, we employ the layered belief propagation (LBP) algorithm whose decoding convergence speed is 1.73 times faster than belief propagation algorithm as the Low-Density Parity-Check (LDPC) decoder for low decoding complexity.

Analysis of Land Cover Characteristics with Object-Based Classification Method - Focusing on the DMZ in Inje-gun, Gangwon-do - (객체기반 분류기법을 이용한 토지피복 특성분석 - 강원도 인제군의 DMZ지역 일원을 대상으로 -)

  • Na, Hyun-Sup;Lee, Jung-Soo
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.17 no.2
    • /
    • pp.121-135
    • /
    • 2014
  • Object-based classification methods provide a valid alternative to traditional pixel-based methods. This study reports the results of an object-based classification to examine land cover in the demilitarized zones(DMZs) of Inje-gun. We used land cover classes(7 classes for main category and 13 classes for sub-category) selected from the criteria by Korea Ministry of Environment. The average and standard deviation of the spectrum values, and homogeneity of GLCM were chosen to map land cover types in an hierarchical approach using the nearest neighborhood method. We then identified the distributional characteristics of land cover by considering 3 topographic characteristics (altitude, slope gradient, distance from the Southern Limited Line(SLL)) within the DMZs. The results showed that scale 72, shape 0.2, color 0.8, compactness 0.5 and smoothness 0.5 were the optimum weight values while scale, shape and color were most influenced parameters in image segmentation. The forests (92%) were main land cover type in the DMZs; the grassland(5%), the urban area (2%) and the forests (broadleaf forest: 44%, mixed forest: 42%, coniferous forest: 6%) also occupied mostly in land cover classes for sub-category. The results also showed that facilities and roads had higher density within 2 km from the SLL, while paddy, field and bare land were distributed largely outside 6 km from the SLL. In addition, there was apparent distinction in land cover by topographic characteristics. The forest had higher density at above altitude 600m and above slope gradient $30^{\circ}$ while agriculture, bare land and grass land were distributed mainly at below altitude 600m and below slope gradient $30^{\circ}$.

Study on Performance Evaluation of Dental X-ray Equipment (치과 방사선 발생기의 성능평가에 관한 연구)

  • Jung, Jae-Eun;Jung, Jae-Ho;Kang, Hee-Doo;Lee, Jong-Woong;Ra, Keuk-Hwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.2
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

Development of Registration Post-Processing Technology to Homogenize the Density of the Scan Data of Earthwork Sites (토공현장 스캔데이터 밀도 균일화를 위한 정합 후처리 기술 개발)

  • Kim, Yonggun;Park, Suyeul;Kim, Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.5
    • /
    • pp.689-699
    • /
    • 2022
  • Recently, high productivity capabilities have been improved due to the application of advanced technologies in various industries, but in the construction industry, productivity improvements have been relatively low. Research on advanced technology for the construction industry is being conducted quickly to overcome the current low productivity. Among advanced technologies, 3D scan technology is widely used for creating 3D digital terrain models at construction sites. In particular, the 3D digital terrain model provides basic data for construction automation processes, such as earthwork machine guidance and control. The quality of the 3D digital terrain model has a lot of influence not only on the performance and acquisition environment of the 3D scanner, but also on the denoising, registration and merging process, which is a preprocessing process for creating a 3D digital terrain model after acquiring terrain scan data. Therefore, it is necessary to improve the terrain scan data processing performance. This study seeks to solve the problem of density inhomogeneity in terrain scan data that arises during the pre-processing step. The study suggests a 'pixel-based point cloud comparison algorithm' and verifies the performance of the algorithm using terrain scan data obtained at an actual earthwork site.