• 제목/요약/키워드: piezoelectric transducer

검색결과 391건 처리시간 0.024초

압전세라믹/고분자 복합압전체 초음파 트랜스듀서를 이용한 3차원 수중 물체 복원 (3D Underwater Object Restoration Using Ultrasonic Transducer Fabricated with Piezoelectric Ceramics/polymer Composites)

  • 조현철;이기성;이수호;박정학;최헌일;사공건
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1537-1539
    • /
    • 1998
  • In this study, 3-D underwater object restoration using ultrasonic transducer fabricated with PZT-Polymer 1-3 type composite are presented. Using the acquired underwater object data 16${\times}$16 pixels. Modified SCL neural networks using the 16${\times}$16 low resolution image was used for underwater object restoration of 32${\times}$32 high resolution Image.

  • PDF

압전형 음향변환기의 음향소자 및 케이스의 설계 (Design of the acoustic element and case for the piezoelectric acoustic transducer)

  • 김현철;고영준;남효덕;장호경
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.294-297
    • /
    • 2000
  • 본 연구에서는 압전형 음향변환기를 제작하기 위한 금속과 세라믹스로 적층된 원형의 압전음향소자와 음향변환기 케이스를 설계하였다. 먼저 음향소자인 복합원형평판의 진동운동 방정식을 세우고 그 진동모드를 알아보았다. 음향소자의 세라믹스는 두께 1 mm, 지름 10 mm의 PZT(IV)를 사용하였고, 금속판의 지름과 두께를 다양하게 변화시키면서 음향소자의 공진주파수를 계산하고, 각각의 금속판에 따른 감도지수의 변화를 계산하였다. 설계하고자 하는 음향소자의 공진주파수를 200 KHz로 청하고, 위의 계산을 통하여 음향변환소자에 가장 적합한 금속진동판을 찾아보았다. 음향변환기의 복합원형평판으로 이루어진 음향소자의 물리적 변화에 따른 공진주파수와 감도지수를 구하고 음향변환기 케이스의 공진주파수를 계산하여 압전형 음향변환기에 알맞은 금속진동판과 음향변환기 케이스를 알아보았다.

  • PDF

고온저장시험에 의한 RF SAW Filter의 고장분석 (Failure Analysis of RF SAW Filter by High Temperature Storage Test)

  • 김영구;김태홍;유종준
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.140-144
    • /
    • 2003
  • To investigate failure analysis of surface acoustic wave (SAW) filter for radio frequency, high temperature storage test was carried out. The failure criteria were insertion loss at passband and rejection level at stopband. As a result, the insertion loss at passband increase about 4 dB was due to damages of interdigital transducer (IDT). That is caused by poor adhesion between metal electrode(AI) and piezoelectric substrate and defects on a manufacturing process. This result indicates that good adhesion between electrode and ceramic substrate is important factor And also we investigated the demage factors of electrode. Screen possible of saw filter using high temperature storage test(HTOL) in the manufacturing phase be presented.

  • PDF

초음파 트랜스듀서에서의 Cross talk 분석 및 방지 방안 (Analysis and Reduction of the Cross Talk in Ultrasonic Transducers)

  • 노용래;김영신;이수성
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2001년도 추계학술발표대회 논문집 제20권 2호
    • /
    • pp.215-218
    • /
    • 2001
  • Finite element models are constructed using the commercial code ANSYS for two most representative types of ultrasonic transducers, cMUTs and piezoelectric transducers. Calculation result shows the origin and level of cross talk between array elements in each transducer type For reduction of the cross talk level, the effects of various structural variations are Investigated for each transducer type. The results say that proper design of the coupling isolation structures between the transducing elements can significantly reduce the cross talk in ultrasonic transducers.

  • PDF

Quadrupole 구조를 가진 Tonpilz형 수중 음향 벡터 센서를 이용한 입사각 추정 (Incidence Angle Estimation by the Tonpilz Type Underwater Acoustic Vector Sensor with a Quadrupole Structure)

  • 임영섭;노용래
    • 한국음향학회지
    • /
    • 제31권8호
    • /
    • pp.569-579
    • /
    • 2012
  • 압전 세라믹을 이용한 전형적인 Tonpilz형 수중 음향센서는 외부에서 들어오는 음향 신호를 이에 상응하는 전압으로 변환해 스칼라 양인 음압의 크기만 측정할 뿐 외부에서 들어오는 신호의 방향은 파악할 수 없는 한계가 있다. 이와 같은 문제점을 해결하고자 본 논문에서는 Tonpilz형 트랜스듀서를 이용해 단일 센서만으로도 음압의 크기와 방위각 방향을 동시에 분석해 낼 수 있는 새로운 벡터 센서 구조를 제안하고, 제안된 구조의 타당성을 수식 및 유한요소해석을 통해 검증하였다.

1-3-0형 복합압전체의 펄스-에코특성 (Pulse-echo Response of Piezoceramics PZT-Polymer 1-3-0 Type Composite)

  • 양윤석;유영준;최헌일;손무헌;사공건
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.303-306
    • /
    • 1999
  • In this study, the piezoelectric ceramics PZT powder was synthesized by Wet-Dry combination method. The flexible 1-3-0 type composites were fabricated with piezoceramic PZT and Eccogel polymer matrix embedded 3rd phase. This paper represents the acoustic properties with various 3rd phase wt.%. The acoustic impedance of 1-3-0 type composites was lower than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with 1-3-0 type composites was better than solid PZT transducer.

  • PDF

알루미늄 실린더 압축실험에서의 고주파 진동의 영향 (Effect of High Frequency Oscillation on Compression Tests of Aluminum Cylindrical Specimens)

  • 김상우;이영선
    • 소성∙가공
    • /
    • 제25권6호
    • /
    • pp.373-378
    • /
    • 2016
  • Recent researches have reported that the superposition of ultrasonic vibrations in metal forming provides beneficial effects such as the reduction of forming load, flow stress and interfacial friction which improves the surface quality of end products. This paper presents experimental investigations on the effects of ultrasonic vibrations in upsetting tests of aluminum. The ultrasonic exciting system consists of piezoelectric transducer and resonator was designed and constructed to superimpose high frequency oscillation on the forming tools. Ultrasonic vibration-assisted upsetting tests were performed for three vibration modes five amplitudes, and the results were compared with those of conventional upsetting tests. The results showed that the superimposition of ultrasonic vibration reduces the upsetting load, and the load reduction is only dependent on the amplitude of the applied vibration regardless of deformation histories and vibration modes.

Two-Dimensional Numerical Modeling and Simulation of Ultrasonic Testing

  • Yim, Hyun-June;Baek, Eun-Sol
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.649-658
    • /
    • 2002
  • As an attempt to further improve the reliability and effectiveness of ultrasonic testing (UT), a two-dimensional numerical simulator of UT was developed. The simulator models the wave medium (or test object) using the mass-spring lattice model (MSLM) that consists of mass-points and springs. Some previous simulation results, obtained by using MSLM, are briefly reviewed in this paper, for propagation, reflection, and scattering of ultrasonic waves. Next, the models of transmitting and receiving piezoelectric transducers are introduced with some numerical results, which is a main focus of this paper. The UT simulator, established by combining the transducer models with the MSLM, was used to simulate many UT setups. In this paper, two simple setups are considered as examples, and their simulated A-scan signals are discussed. The potential of the MSLM, transducer models, and the UT simulator developed in this study to be used in the actual UT is confirmed.

Electroactive Paper(EAPap)를 이용한 표면탄성파 센서 (Surface Acoustic Wave Sensor Using Electroactive Paper(EAPap))

  • 이민희;김주형;김재환
    • 한국소음진동공학회논문집
    • /
    • 제18권11호
    • /
    • pp.1128-1133
    • /
    • 2008
  • Cellulose based electroactive paper(EAPap) has been developed as a new smart material due to its advantages of piezoelectricity, large displacement, low power consumption, low cost and flexibility. EAPap can be used for a surface acoustic wave (SAW) device using the piezoelectric property of EAPap, resulting in the cost effective and flexible SAW device. In this paper, inter digit transducer(IDT) structure using lift-off technique with a finger gap of 10mm was used for micro fabrication of the cellulose EAPap SAW devices. The performance of IDT patterned SAW device was characterized by a Network Analyzer. The feasibility of cellulose EAPap as a potential acoustic device was presented and explained.

약물 이송기능을 갖는 복합구조 초음파 변환기 어셈블리 개발에 관한 연구 (A Study on Development of Composite Ultrasonic Transducer Assembly with Drug Transfer Function)

  • 노시철;김주영;유병철;정봉재
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.353-359
    • /
    • 2017
  • 대표적인 저강도 초음파 자극 기술인 음파영동은 초음파의 물리적 진동과 온열 효과를 이용하여 약물을 인체 표피 내부로 전달시키는 기법이다. 음파영동법은 치료 약물 전달의 효율을 높일 수 있으며, 인슐린이나 지질 등 분자 크기가 비교적 큰 약물의 전달에도 효과적이라는 장점을 갖는다. 본 연구에서는 효율적인 음파영동 치료를 위하여 대면적 단일 진동소자와 치료 부위에 약물 이송 기능을 갖는 복합 구조 초음파 변환기 어셈블리를 제안하였다. 또한, 치료 부위의 온도를 상승 및 유지시킬 수 있는 변환기 어셈블리 구조를 제안하고 유효성을 평가하였다. 본 연구에서 제안된 변환기 어셈블리는 지속적으로 정량의 약물을 제공하고, 가온을 통하여 약물 전달을 보조함으로써 초음파를 이용한 음파영동 시술의 효율을 향상시킬 수 있을 것으로 사료된다.