• Title/Summary/Keyword: piezoelectric effect

Search Result 648, Processing Time 0.028 seconds

A study on the measurement of the current & voltage using Photoelastic effect of Optical Fiber (광섬유의 photoelastic효과를 이용한 전류및 전압의 측정에 관한 연구)

  • Choi, Do-In;Kim, Chang-Hyun;Kim, Ho-Seong
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1268-1270
    • /
    • 1995
  • A method using photoelectric effect of a single-mode optical fiber, with a 632.8nm He-Ne laser, has been developed for the simultaneous measurment of current and voltage. The Magnetic stress for the current and the piezoelectric effect for voltage are utilized. It is found that the detector output voltage is proportional to the square of the applied current and the frequency of the output is twice of that of the applied current.

  • PDF

PCA-based filtering of temperature effect on impedance monitoring in prestressed tendon anchorage

  • Huynh, Thanh-Canh;Dang, Ngoc-Loi;Kim, Jeong-Tae
    • Smart Structures and Systems
    • /
    • v.22 no.1
    • /
    • pp.57-70
    • /
    • 2018
  • For the long-term structural health monitoring of civil structures, the effect of ambient temperature variation has been regarded as one of the critical issues. In this study, a principal component analysis (PCA)-based algorithm is proposed to filter out temperature effects on electromechanical impedance (EMI) monitoring of prestressed tendon anchorages. Firstly, the EMI monitoring via a piezoelectric interface device is described for prestress-loss detection in the tendon anchorage system. Secondly, the PCA-based temperature filtering algorithm tailored to the EMI monitoring of the prestressed tendon anchorage is outlined. The proposed algorithm utilizes the damage-sensitive features obtained from sub-ranges of the EMI data to establish the PCA-based filter model. Finally, the feasibility of the PCA-based algorithm is experimentally evaluated by distinguishing temperature changes from prestress-loss events in a prestressed concrete girder. The accuracy of the prestress-loss detection results is discussed with respect to the EMI features before and after the temperature filtering.

The characteristics of ceramic filter using energy trapping effect (에너지 트래핑 효과를 이용한 세라믹 필터의 특성에 관한 연구)

  • 박기엽;김원석;송준태
    • Electrical & Electronic Materials
    • /
    • v.8 no.2
    • /
    • pp.144-150
    • /
    • 1995
  • Ceramic filter using energy trapping effect is used bandpass filter at high frequency. In this paper, the resonant points of the symmetrical modes and antisymmetrical modes were theoretically analyed and synthesized these modes in order to know the filter characteristics. We simulated them using the computer and also fabricated the ceramic filter using PZT-4 piezoelectric plate made by Valpey Fisher Co., The 1.5[.mu.m] - thick platinum electrode were deposited on the ceramic plates with the various masks. The characteristics of the fabricated filters were measured using the spectrum analyzer. Experimental data were compared with the theoretical results. The maximum-pass frequencies coinsided exactly. The bandwidths of the fabricated filters were slightly different between theoretical and experimental results. We found that these phenomenon were caused by the stray capacitance between the two neighbor electrodes..

  • PDF

The PTCR Effect of Semiconducting Zn-Ti-Ni-O Ceramics (Zn-Ti-Ni-O 반도성 세라믹스의 PTCR 현상)

  • Ko, Il-Young;Choi, Seung-Chul;Kim, Hwan
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.8
    • /
    • pp.609-614
    • /
    • 1993
  • Semiconducting Zn-Ti-Ni-O and Zn-Ti-O system were investigated. The specimens sintered at the temperature between 125$0^{\circ}C$ and 145$0^{\circ}C$ exhibited PTCR effect between -5$0^{\circ}C$ and 35$0^{\circ}C$ with resistivity ration exceeding three decades. Semiconducting Zn-Ti-Ni-O is consisted of two phases, one is n-type ZnO and the other is p-type spinel structure. The mechanism of PTCR effect was explained in relation to the piezoelectric property of ZnO and the residual stress caused by thermal expansion difference between two phases during cooling process.

  • PDF

Electrocaloric Effect in Emerging Fluorite-Structure Ferroelectrics (새로운 플루오라이트 구조 강유전체의 Electrocaloric Effect)

  • Yang, Kun;Park, Ju Yong;Lee, Dong Hyun;Park, Min Hyuk
    • Korean Journal of Materials Research
    • /
    • v.30 no.9
    • /
    • pp.480-488
    • /
    • 2020
  • The electrocaloric effect can be observed in pyroelectric materials based on conversion between electrical and thermal energy, and can be utilized for the future environment-friendly refrigeration technology. Especially, a strong electrocaloric effect is expected in materials in which field-induced phase transition can be achieved. Emerging fluorite-structure ferroelectrics such as doped hafnia and zirconia, first discovered in 2011, are considered the most promising materials for next-generation semiconductor devices. Besides application of fluorite-structure ferroelectrics for semiconductor devices based on their scalability and CMOS-compatibility, field-induced phase transition has been suggested as another interesting phenomenon for various energy-related applications such as solid-state cooling with electrocaloric effect as well as energy conversion/storage and IR/piezoelectric sensors. Especially, their giant electrocaloric effect is considered promising for solid-state-cooling. However, the electrocaloric effect of fluorite-structure oxides based on field-induced phase transition has not been reviewed to date. In this review, therefore, the electrocaloric effect accompanied by field-induced phase transition in fluorite-structure ferroelectrics is comprehensively reviewed from fundamentals to potential applications.

Quantitative Alpha Fetoprotein Detection with a Piezoelectric Microcantilever Mass Sensor (압전 마이크로캔틸레버 질량센서를 이용한 정량적 알파태아단백 검출)

  • Lee, Sangk-Yu;Cho, Jong-Yun;Lee, Yeol-Ho;Jeon, Sang-Min;Cha, Hyung-Joon;Moon, Wonk-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.487-493
    • /
    • 2011
  • Alpha fetoprotein(AFP), which is serological marker for hepatocellular carcinoma, was quantitatively measured by its normal concentration, 10 ng/ml, with a label-free piezoelectric microcantilever mass sensor. The principle of detection is based on changes in the resonant frequency of the piezoelectric microcantilever before and after target molecules are attached to it, and its resonant frequency is measured electrically using a conductance spectrum. The resonant frequency of the developed sensor is approximately 1.34 MHz and the mass sensitivity is approximately 175 Hz/pg. The sensor has high reliability as mass sensor by reducing the effect of surface stress on resonant frequency due to attached proteins. 'Dip and dry' technique was used to react the sensor with reagents for immobilizing AFP antibody on the sensor and detecting AFP antigen. The measured mass of the detected AFP antigen was 6.02 pg at the concentration of 10 ng/ml, and 10.67 pg at 50 ng/ml when the immunoreaction time was 10 min.

Influence to the Doppler Images by the Defects of Piezoelectric Elements of the Probe of Medical Ultrasonic Scanners (Focusing on the Impact of an Increase in the Defects of Piezoelectric Elements) (초음파 프로브 소자 결함이 도플러 영상에 미치는 영향 (소자 결함 증가에 따른 영향을 중심으로))

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. This work was implemented that the quality of Doppler images depended on the extent and location of the probe element defected. The probe performance was rated in terms of the number of piezoelectric elements lost and this was studied in the experiment by electrical disconnection to the elements. The results showed that Doppler velocity became rapidly reduced as the defected elements encountered with the element group activated at the Doppler mode, not as the flow velocity. The effect of the probe defect is decreased when the defects occurred at the element group activated for Doppler mode, as was increased the number of the elements. It was observed that the higher the flow velocity of Doppler flow phantom is, the wider the spectrum of Doppler is. And the Doppler velocity soared up and the dispersion of image brightness is increased when the defected elements got out of the elements activated at Doppler mode. The result showed that TADVP(time-average-Doppler-velocity-profile) is decreased with the increase of the probe element defect, especilly in the region of high frequency. It is expected that the research of various defects of probe elements are needed, and this study can be practical tools for probe based ultrasonic QA in the future.

Fabrication of pyroelectric IR sensors with PLT thin plates compensating for piezoelectric effect (PLT 박편을 이용한 압전특성이 보상된 초전형 적외선 센서의 제작)

  • Kim, Young-Eil;Roh, Yong-Rae;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-5
    • /
    • 1997
  • Highly sensitive pyroelectric IR sensors were fabricated with La-modified $PbTiO_{3}(PLT)$ thin plates compensating for piezoelectric effect. The device was fabricated in a dual form by placing two PLT cells, each of $1{\times}2\;mm^{2}$, side by side with appropriate electrode configuration. The dual element sensor had a signal to noise ratio of about 350 that was much larger than that of single element sensors. Further the dual element sensors exhibited excellent pyroelectric properties such as a large voltage responsivity of 2400 V/W, a pyro-coefficient of $4.6{\times}10^{-8}\;C/cm^{2}K$, a voltage figure of merit of $4.2{\times}10^{-11}\;Ccm/J$, and a small thermal time constant of 8.7 msec. It was confirmed through experiments that the dual element sensor was applicable to detect the two-dimensional moving direction of human beings.

  • PDF

Effect of Electric Field Concentration by Electrode Patterning on the Incipient Piezoelectric Strain Properties of Lead-Free Piezoceramics

  • Kang, Woo-Seok;Hong, Chang-Hyo;Lee, Young-Jin;Choi, Gangho;Shin, Dong-Jin;Lim, Dong-Hwan;Jeong, Soon-Jong;Jo, Wook
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.6
    • /
    • pp.549-557
    • /
    • 2019
  • More than two decades of world-wide research efforts have resulted in several classes of potentially important materials. Among them are incipient piezoelectrics, which are especially useful for actuator applications. However, relatively large electric fields are required for activating the large incipient electromechanical strains. So far, many attempts have been made to reduce the required electric field by intentionally inhomogenizing the electric field distribution in the microstructure through core-shell and composite approaches. Here, we show that electric field concentration can be realized simply by adjusting electrode patterns. We have investigated the effect of electrode patterning on the incipient electromechanical strain properties of an exemplarily chosen lead-free relaxor system, revealing that electrode patterning does have a significant role on the strain properties of the given lead-free relaxor system. We believe that this approach would make a new strategy for ones to consider bringing the functional properties of electroceramics beyond their conventional limit.

Dynamic Characteristics and Piezoelectric Effect of Energy Harvesting Block Structures with Different Shapes (다양한 형상 변화에 따른 에너지 수확용 블록 구조의 동적 특성 및 압전 효과)

  • Noh, Myung-Hyun;Lee, Sang-Youl
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6A
    • /
    • pp.379-387
    • /
    • 2012
  • This study investigates free vibration characteristics of new energy harvesting multi-layer block structures with different geometrical shapes using solid and shell finite elements and evaluate their piezoelectric effect on experiments. The two and three-dimensional finite element (FE) delamination models for block structures described in this paper is attractive not only because it shows excellent accuracy in analysis but also it shows the entire vibration mode shape. The FE model using ABAQUS is used for studying free vibrations of multi-layer block structures for various tip mass and PZT. In particular, new results reported in this paper are focused on the significant effects of the global and local vibration modes for various parameters, such as size of block shape, existence of tip mass and hole, and location of tip mass and PZT. In addition, we evaluate the power generation capacity of developed energy block structures through a laboratory-scale experiment.