Browse > Article
http://dx.doi.org/10.12989/sss.2018.22.1.057

PCA-based filtering of temperature effect on impedance monitoring in prestressed tendon anchorage  

Huynh, Thanh-Canh (Department of Ocean Engineering, Pukyong National University)
Dang, Ngoc-Loi (Department of Ocean Engineering, Pukyong National University)
Kim, Jeong-Tae (Department of Ocean Engineering, Pukyong National University)
Publication Information
Smart Structures and Systems / v.22, no.1, 2018 , pp. 57-70 More about this Journal
Abstract
For the long-term structural health monitoring of civil structures, the effect of ambient temperature variation has been regarded as one of the critical issues. In this study, a principal component analysis (PCA)-based algorithm is proposed to filter out temperature effects on electromechanical impedance (EMI) monitoring of prestressed tendon anchorages. Firstly, the EMI monitoring via a piezoelectric interface device is described for prestress-loss detection in the tendon anchorage system. Secondly, the PCA-based temperature filtering algorithm tailored to the EMI monitoring of the prestressed tendon anchorage is outlined. The proposed algorithm utilizes the damage-sensitive features obtained from sub-ranges of the EMI data to establish the PCA-based filter model. Finally, the feasibility of the PCA-based algorithm is experimentally evaluated by distinguishing temperature changes from prestress-loss events in a prestressed concrete girder. The accuracy of the prestress-loss detection results is discussed with respect to the EMI features before and after the temperature filtering.
Keywords
electromechanical impedance; impedance monitoring; temperature effect; temperature filtering; principal component analysis; prestressed tendon anchorage; prestress-loss;
Citations & Related Records
Times Cited By KSCI : 11  (Citation Analysis)
연도 인용수 순위
1 Huynh, T.C. and Kim, J.T. (2014), "Impedance-based cable force monitoring in tendon-anchorage using portable PZT-interface technique", Math. Probl. Eng., 2014, 1-11.
2 Huynh, T.C. and Kim, J.T. (2016), "Compensation of temperature effect on impedance responses of PZT interface for prestressloss monitoring in PSC girders", Smart Struct. Syst., 17(6), 881-901.   DOI
3 Huynh, T.C. and Kim, J.T. (2017a), "Quantitative damage identification in tendon anchorage via PZT interface-based impedance monitoring technique", Smart Struct. Syst., 20(2), 181-195.   DOI
4 Huynh, T.C. and Kim, J.T. (2017b), "FOS-based prestress force monitoring and temperature effect on unbonded tendon of PSC girder", J. Aerosp. Eng., 30(2), 1-14.
5 Huynh, T.C. and Kim, J.T. (2018), "RBFN-based temperature compensation method for impedance monitoring in prestressed tendon anchorage", Struct. Control Health Monit., 25(6), e2173.   DOI
6 Huynh, T.C., Dang, N.L. and Kim, J.T. (2017), "Advances and challenges in impedance-based structural health monitoring", Struct. Monit. Maint., 4(4), 301-329.   DOI
7 Huynh, T.C., Park, Y.H., Park, J.H., Hong, D.S. and Kim, J.T. (2015a), "Effect of temperature variation on vibration monitoring of prestressed concrete girders", Shock Vib., 2015, 1-9.
8 Huynh, T.C., Park, Y.H., Park, J.H. and Kim, J.T. (2015b), "Feasibility verification of mountable PZT-interface for impedance monitoring in tendon-anchorage", Shock Vib., 2015, 1-11.
9 Jlooiffe, I.T. (1986), Principal Component Analysis, Springer, New York.
10 Kim, J.T., Nguyen, K.D. and Huynh, T.C. (2013), "Wireless health monitoring of stay cable using piezoelectric strain response and smart skin technique", Smart Struct. Syst., 12(3-4), 381-397.   DOI
11 Koo, K.Y., Park, S., Lee, J.J. and Yun, C.B. (2009), "Automated impedance-based structural health monitoring incorporating effective frequency shift for compensating temperature effects", J. Intel. Mat. Syst. Str., 20, 367-377.   DOI
12 Kim, J.T., Park, J.H., Hong, D.S. and Park, W.S. (2010), "Hybrid health monitoring of prestressed concrete girder bridges by sequential vibration-impedance approaches", Eng. Struct., 32, 115-128.   DOI
13 Kim, J.T., Huynh, T.C. and Lee, S.Y. (2014), "Wireless structural health monitoring of stay cables under two consecutive typhoons", Struct. Monit. Maint., 1(1), 47-67.   DOI
14 Kim, J.T., Yun, C.B. and Yi, J.H. (2003), "Temperature effects on frequency-based damage detection in plate-girder bridges", J. KSCE, 7(6), 725-733.
15 Mascarenas, D, Todd, M.D., Park, G. and Farrar, C.R. (2007), "Development of an impedance-based wireless sensor node for structural health monitoring", Smart Mater. Struct., 16(6), 2137-2145.   DOI
16 Koo, K.Y., Park, S., Lee, J.J. and Yun, C.B. (2008), "Temperature effects-free impedance-based structural health monitoring using principal component analysis", Proceedings of IMAC-XXVI: Conference & Exposition on Structural Dynamics, 1-6.
17 Liang, C., Sun, F.P. and Rogers, C.A. (1994), "Coupled electromechanical analysis of adaptive material-Determination of the actuator power consumption and system energy transfer", J. Intel. Mat. Syst. Str., 5, 12-20.   DOI
18 Lim, H.J., Kim, M.K., Sohn, H. and Park, C.Y. (2011), "Impedance-based damage detection under varying temperature and loading conditions", NDT&E Int., 44, 740-750.   DOI
19 Min, J., Shim, H., Yun, C.B. and Hong, J.W. (2016), "An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems", Smart Struct. Syst., 17(1), 107-122.   DOI
20 Min, J., Yi, J.H. and Yun, C.B. (2015), "Electromechanical impedance-based long-term SHM for jacket-type tidal current power plant structure", Smart Struct. Syst., 15(2), 283-297.   DOI
21 Nguyen, K.D. and Kim, J.T. (2012), "Smart PZT-interface for wireless impedance-based prestress-loss monitoring in tendonanchorage connection", Smart Struct. Syst., 9(6), 489-504.   DOI
22 Nguyen, T.C., Huynh, T.C., Yi, J.H. and Kim, J.T. (2017), "Hybrid bolt-loosening detection in wind turbine tower structures by vibration and impedance responses", Wind Struct., 24(4), 385-403.   DOI
23 Park, J.H., Kim, J.T., Hong, D.S., Mascarenas, D. and Lynch, J.P. (2010), "Autonomous smart sensor nodes for global and local damage detection of prestressed concrete bridges based on accelerations and impedance measurements", Smart Struct. Syst., 6(5), 711-730.   DOI
24 Park, G., Kabeya, K., Cudney, H. and Inman, D. (1999), "Impedance-based structural health monitoring for temperature varying applications", JSME International Journal Series A Solid Mechanics and Material Engineering, 42, 249-258.   DOI
25 Park, G., Sohn, H., Farrar, C. and Inman, D. (2003), "Overview of piezoelectric impedance-based health monitoring and path forward", Shock Vib. Digest, 35(6), 451-463.   DOI
26 Park, J.H., Huynh, T.C. and Kim, J.T. (2015), "Temperature effect on wireless impedance monitoring in tendon anchorage of prestressed concrete girder", Smart Struct. Syst., 15(4), 1159-1175.   DOI
27 Park, S., Lee, J.J. and Yun, C.B. (2008), "Electro-mechanical impedance-based wireless structural health monitoring using PCA-data compression and k-means clustering algorithms", J. Intel. Mat. Syst. Str., 19(4), 509-520.   DOI
28 Ryu, J.Y., Huynh, T.C. and Kim, J.T. (2017), "Experimental investigation of magnetic-mount PZT interface for impedancebased damage detection in steel girder connection", Struct. Monit. Maint., 4(3), 237-253.   DOI
29 Sim, S.H., Li, J., Jo, H., Park, J.W., Cho, S., Spencer Jr, B.F. and Jung, H.J. (2014), "A wireless smart sensor network for automated monitoring of cable tension", Smart Mater. Struct., 23, 1-10.
30 Sepehry, N., Shamshirsaz, M. and Abdollahi, F. (2011), "Temperature variation effect compensation in impedance-based structural health monitoring using neural networks", J. Intel. Mat. Syst. Str., 20(10), 1-8.
31 Sun, F.P., Chaudhry Z., Liang, C. and Rogers C.A. (1995), "Truss structure integrity identification using PZT sensor-actuator", J. Intel. Mat. Syst. Str., 6, 134-139.   DOI
32 Soh, C.K., Tseng, K.K., Bhalla, S. and Gupta, A. (2000), "Performance of smart piezoceramic patches in health monitoring of a RC bridge", Smart Mater. Struct., 9, 533-542.   DOI
33 Soh, C.K., Yang, Y. and Bhalla, S. (2012), Smart Materials in Structural Health Monitoring, Control and Biomechanics, Springer-Verlag Berlin Heidelberg
34 Sohn, H. (2007), "Effects of environmental and operational variability on structural health monitoring", Philosophical Transactions of the Royal Society A, 365, 539-560.   DOI
35 Wang, D., Wang. Q., Wang, H. and Zhu H. (2016), "Experimental study on damage detection in timber specimens based on an electromechanical impedance technique and RMSD-based Mahalanobis distance", Sensors, 1-17.
36 Woon, C.E. and Mitchell, L.D. (1996), "Variations in structural dynamic characteristics caused by changes in ambient temperature: Part I. Experimental", Proceeding of the 14th IMAC, SEM.
37 Yang, Y., Annamdas, V.G.M., Wang, C. and Zhou, Y. (2008), "Application of multiplexed FBG and PZT impedance sensors for health monitoring of rocks", Sensors, 8, 271-289.   DOI
38 Zagrai, A.N. and Giurgiutiu, V. (2001), "Electro-mechanical impedance method for crack detection in thin plates", J. Intel. Mat. Syst. Str., 12, 709-718.   DOI
39 Chaudhry, Z., Joseph, T., Sun, F. and Rogers, C. (1995). "Localarea health monitoring of aircraft via piezoelectric actuator/sensor patches", Smart Structures and Integrated Systems, Proceedings of the SPIE, 2443, San Diego, CA.
40 Ayres, J.W., Lalande, F., Chaudhry, Z. and Rogers, C.A. (1998), "Qualitative impedance-based health monitoring of civil infrastructures", Smart Mater. Struct., 7, 599-605.   DOI
41 Fabricio G.B., Danilo E.B., Vinicius A.D.A. and Jose A.C.U. (2014), "An experimental study on the effect of temperature on piezoelectric sensors for impedance-based structural health monitoring", Sensors, 14, 1208-1227.   DOI
42 Ho, D.D., Lee, P.Y., Nguyen, K.D., Hong, D.S., Lee, S.Y., Kim, J.T., Shin, S.W., Yun, C.B. and Shinozuka, M. (2012), "Solarpowered multi-scale sensor node on Imote2 platform for hybrid SHM in cable-stayed bridge", Smart Struct. Syst., 9(2), 145-164.   DOI
43 Ho, D.D., Ngo, T.M. and Kim, J.T. (2014), "Impedance-based damage monitoring of steel column connection: numerical simulation", Struct. Monit. Maint., 1(3), 339-356.   DOI
44 Ho, D.D., Nguyen, K.D., Yoon, H.S. and Kim, J.T. (2012), "Multiscale acceleration-dynamic strain-impedance sensor system for structural health monitoring", Int. J. Distrib. Sens. N., 2012, 1-17.
45 Hu, X., Zhu, H. and Wang, D. (2014), "A study of concrete slab damage detection based on the electromechanical impedance method", Sensors, 14, 19897-19909.   DOI
46 Zahedi, F. and Huang, H. (2017), "Time-frequency analysis of electromechanical impedance (EMI) signature for physics-based damage detections using piezoelectric wafer active sensor (PWAS)", Smart Mater. Struct., 26, 1-9.
47 Johnson, K.L. (1985), Contact Mechanics, Cambridge University Press, Cambridge.
48 Hong, D.S., Nguyen, K.D., Lee, I.C. and Kim, J.T. (2012), "Temperature-compensated damage monitoring by using wireless acceleration-impedance sensor nodes in steel girder connection", Int. J. Distrib. Sens. N., 2012, 1-12.
49 Hooker, M.W. (1998), "Properties of PZT-based piezoelectric ceramics between-150 and $250^{\circ}C$", Technical Report NASA/CR-1998-208708, NASA, USA