• Title/Summary/Keyword: photonics

Search Result 3,967, Processing Time 0.027 seconds

3D Precision Measurement of Scanning Moire Using Line Scan Camera (라인스캔 카메라를 이용한 3차원 정밀 측정)

  • Kim, Hyun-Ju;Yoon, Doo-Hyun;Kim, Hak-Il
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.5
    • /
    • pp.376-380
    • /
    • 2008
  • This paper presents the Projection Moire method using a line scan camera. The high resolution feature of a line scan camera makes it possible to scan an image quickly, thus enabling a much quicker 3D profile. This method uses a high resolution line scan camera making it possible to scan an image at high speed simultaneously measuring the 3D profile of a large FOV. When using a high resolution scan camera, a full FOV is scanned, thus requiring just one movement of a projection grating. As a result, the number of grating movements is reduced drastically. The end result is a faster and more accurate 3D measurement. Moving the grating too quickly causes vibration in the imaging system, which will normally be required to apply a stitching technique when using an area scan camera. However the technique is not required when using a line scan camera. Compared with the previous techniques, it has the advantages of simple hardware without moving mechanical parts - single exposure for obtaining three-dimensional information. A method using a high resolution line scan camera can be used in mass production to measure the bump height of wafers or the bump height of package substrates.

Comparison of Misalignment and Retardation Errors of Dual Rotating Quarter-Wave Plates in Muller-Matrix Ellipsometry (타원편광 분석기에서 정렬오차와 사분파장판의 지연오차로 인한 뮬러 매트릭스 오차 분석)

  • Cheong, Hai Du;Kim, Dukhyeon
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.5
    • /
    • pp.262-272
    • /
    • 2014
  • Using an ellipsometer with dual rotating quarter-wave plates, we have analyzed the relationship between Fourier coefficients and Mueller matrices in the cases of an error-free optical system and of five systematic errors (alignment errors and retardation errors in the quarter-wave plates, and alignment error in the analyzer). In the case with five systematic errors, simulation results show that retardation errors cause more error in the diagonal elements of the Mueller matrix than do alignment errors. We have found that errors in the Mueller matrix caused by initial misalignment of the dual quarter-wave plates were the same. We have chosen the rotation rates of two quarter-wave plates such that the rotational frequencies ${\omega}_1$ and ${\omega}_2$ differ by a factor of 5, i.e. ${\omega}_2=5{\omega}_1$. The simulation results show 0.18% relative error in the diagonal elements ($m_{22}$ and $m_{33}$) and 200% relative error in the off-diagonal elements ($m_{23}$ and $m_{32}$), when we compare errors caused by misalignment of the analyzer to those caused by initial misalignment of the quarter-wave plates. We can use these results in measuring accurate Mueller matrices of optical materials.

Smart Headlamp Optics Design with Multi-array LEDs (멀티 어레이 엘이디를 이용한 지능형 전조등 광학 설계)

  • Yu, Jin Hee;Ro, Suk Ju;Lee, Jun Ho;Hwang, Chang Kook;Go, Dong Jin
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.231-236
    • /
    • 2013
  • We investigated the optical design of a smart headlamp capable of producing various beam patterns through only on/off modulation of light sources. This was implemented by forming a continuous matrix of beams from discontinuous beam patterns by means of a multi-array LED optical system. As one such optical system, the multi-array LED system is a convenient and economical device for implementing beam patterns with the simple on/off modulation of the light sources. A single optical assembly module can be made by combining a multiple-LED array, optical system module, and electronic control with no need for any additional mechanical components. The present optical system was designed to include a secondary lens and a projection lens mounted at the front of each LED in the array to realize accurate lighting patterns as well as the required luminosity at a distance of 25 m in the forward direction. Finally, we identified and analyzed the patterns implemented by the designed optical system that produced satisfactory performance of high beams and adaptive driving beams (ADB).

A simple Demonstration of the Wiener-Khinchin Theorem using a Digital Oscilloscope and Personal Computer (디지털 오실로스코프에 의한 Wiener-Khinchin 정리의 시현)

  • Jung, Se-Min
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.245-250
    • /
    • 2013
  • The Wiener-Khinchin theorem, which means that the autocorrelation function of a signal corresponds to the power spectrum of the signal, is very important in signal processing, spectroscopy and telecommunications engineering. However, because of needs for some relatively expensive equipments such as a correlator and the signal processing system, its demonstration in most undergraduate class is not easy so far. Recently, digital oscilloscopes whose functions can be replaced foresaid equipments are marketed with development of digital engineering. In this paper, a simple demonstration of the theorem is given by a digital storage oscilloscope and a personal computer with its theoretical background. The reason that deals again with this theorem which has been introduced in 1930 is that it has been not well informed yet to us and theoretical background of the demonstration is directly introduced from its driving process. Through deriving process of the theorem, some extended physical meanings of the impedance, power, power factor, Wiener spectrum, linear system response and, furthermore, basic idea of the Planck's quantization in the black body theory reveal themselves naturally. Hence it can be referred to lectures in general physics, modern physics, spectroscopy and material characterization experiment.

Design and Analysis of a Laser Lift-Off System using an Excimer Laser (엑시머 레이저를 사용한 LLO 시스템 설계 및 분석)

  • Kim, Bo Young;Kim, Joon Ha;Byeon, Jin A;Lee, Jun Ho;Seo, Jong Hyun;Lee, Jong Moo
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.224-230
    • /
    • 2013
  • Laser Lift-Off (LLO) is a process that removes a GaN or AIN thin layer from a sapphire wafer to manufacture vertical-type LEDs. It consists of a light source, an attenuator, a mask, a projection lens and a beam homogenizer. In this paper, we design an attenuator and a projection lens. We use the 'ZEMAX' optical design software for analysis of depth of focus and for a projection lens design which makes $7{\times}7mm^2$ beam size by projecting a beam on a wafer. Using the 'LightTools' lighting design software, we analyze the size and uniformity of the beam projected by the projection lens on the wafer. The performance analysis found that the size of the square-shaped beam is $6.97{\times}6.96mm^2$, with 91.8 % uniformity and ${\pm}30{\mu}m$ focus depth. In addition, this study performs dielectric coating using the 'Essential Macleod' to increase the transmittance of an attenuator. As a result, for 23 layers of thin films, the transmittance total has 10-96% at angle of incidence $45-60^{\circ}$ in S-polarization.

Performance Prediction of a Laser-guide Star Adaptive Optics System for a 1.6 m Telescope

  • Lee, Jun Ho;Lee, Sang Eun;Kong, Young Jun
    • Current Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.269-279
    • /
    • 2018
  • We are currently investigating the feasibility of a 1.6 m telescope with a laser-guide star adaptive optics (AO) system. The telescope, if successfully commissioned, would be the first dedicated adaptive optics observatory in South Korea. The 1.6 m telescope is an f/13.6 Cassegrain telescope with a focal length of 21.7 m. This paper first reviews atmospheric seeing conditions measured over a year in 2014~2015 at the Bohyun Observatory, South Korea, which corresponds to an area from 11.6 to 21.6 cm within 95% probability with regard to the Fried parameter of 880 nm at a telescope pupil plane. We then derive principal seeing conditions such as the Fried parameter and Greenwood frequency for eight astronomical spectral bands (V/R/I/J/H/K/L/M centered at 0.55, 0.64, 0.79, 1.22, 1.65, 2.20, 3.55, and $4.77{\mu}m$). Then we propose an AO system with a laser guide star for the 1.6 m telescope based on the seeing conditions. The proposed AO system consists of a fast tip/tilt secondary mirror, a $17{\times}17$ deformable mirror, a $16{\times}16$ Shack-Hartmann sensor, and a sodium laser guide star (589.2 nm). The high order AO system is close-looped with 2 KHz sampling frequency while the tip/tilt mirror is independently close-looped with 63 Hz sampling frequency. The AO system has three operational concepts: 1) bright target observation with its own wavefront sensing, 2) less bright star observation with wavefront sensing from another bright natural guide star (NGS), and 3) faint target observation with tip/tilt sensing from a bright natural guide star and wavefront sensing from a laser guide star. We name these three concepts 'None', 'NGS only', and 'LGS + NGS', respectively. Following a thorough investigation into the error sources of the AO system, we predict the root mean square (RMS) wavefront error of the system and its corresponding Strehl ratio over nine analysis cases over the worst ($2{\sigma}$) seeing conditions. From the analysis, we expect Strehl ratio >0.3 in most seeing conditions with guide stars.

Prediction Method for Moisture-release Surface Deformation of a Large Mirror in the Space Environment (우주환경에서 대형 반사경의 습기 방출에 의한 형상 변화 예측방법)

  • Song, In-Ung;Yang, Ho-Soon;Khim, Hagyong;Kim, Seong-Hui;Lee, Hoi-Yoon;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.29 no.4
    • /
    • pp.166-172
    • /
    • 2018
  • In this paper, we propose a new method to predict a mirror's surface deformation due to the stress of moisture release by a coating in the environment of outer space. We measured the surface deformation of circular samples 50 mm in diameter and 1.03 mm thick, using an interferometer. The results were analyzed using Zernike fringe polynomials. The coating stress caused by moisture release was calculated to be 152.7 MPa. This value was applied to an analytic model of a 1.25 mm thickness sample mirror, confirming that the change of surface deformation could be predicted within the standard deviation of the measurement result ($78.9{\pm}5.9nm$). Using this methodology, we predicted the surface deformation of 600 mm hyperbolic mirror for the Compact Advanced Satellite, which will be launched in 2019. The result is only $2.005{\mu}m$ of focal shift, leading to 2.3% degradation of modulation transfer function (MTF) at the Nyquist frequency, which satisfies the requirement.

Luminescence Characteristics of Blue Phosphor and Fabrication of a UV-based White LED (UV 기반 백색 LED용 청색 형광체의 발광특성 및 백색 LED 제조)

  • Jung, Hyungsik;Park, Seongwoo;Kim, Taehoon;Kim, Jongsu
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.4
    • /
    • pp.216-220
    • /
    • 2014
  • We have synthesized a $CaMgSi_2O_6:Eu^{2+}$ blue phosphor via a solid-state reaction method. The $CaMgSi_2O_6:Eu^{2+}$ phosphor has monoclinic structure with a space group of C2/c (15), and an emission band peaking at 450 nm (blue) due to the $4f^7-4f^65d$ transition of the $Eu^{2+}ion$. The emission intensity at $100^{\circ}C$ is 54% of the value at room temperature. A white LED was fabricated by integrating a UV LED (400 nm) with our blue phosphor plus two commercial green and red phosphors. The white LED shows a color temperature of 3500 K with a color rendering index of 87 (x = 0.3936, y = 0.3605), and a luminous efficiency of 18 lm/W. The white LED shows a luminance maintenance of 97% after operation at 350 mA for 400 hours at $85^{\circ}C$.

Measurement of Large Mirror Surface using a Laser Tracker (레이저트래커(Laser Tracker)를 이용한 대형 광학 거울의 형상 측정)

  • Jo, Eun-Ha;Yang, Ho-Soon;Lee, Yun-Woo
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.6
    • /
    • pp.331-337
    • /
    • 2013
  • A large optical surface is fabricated by grinding, polishing and figuring. The grinding process is the most rapid and has the largest amount of fabrication of all processes. If we measure the surface precisely and rapidly in the grinding process, it is possible to improve the efficiency of the fabrication process. Since the surface of grinding process is rough and not shiny, it is not easy to measure the surface using light so that we cannot use an interferometer. Therefore, we have to measure the surface using a mechanical method. We can measure the surface under the grinding process by using a laser tracker which is a portable 3-dimensional coordinate measuring machine. In this paper, we used the laser tracker to measure the surface error of 1 m diameter spherical mirror. This measurement result was compared to that of an interferometer. As a result, surface measurement error was found to be $0.2{\mu}m$ rms (root mean square) and $2.7{\mu}m$ PV (Peak to Valley), which is accurate enough to apply to the rough surface under the grinding stage.

3-Dimensional LADAR Optical Detector Development in Geiger Mode Operation (Geiger Mode로 동작하는 3차원 LADAR 광수신기 개발)

  • Choi, Soon-Gyu;Shin, Jung-Hwan;Kang, Sang-Gu;Hong, Jung-Ho;Kwon, Yong-Joon;Kang, Eung-Cheol;Lee, Chang-Jae
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.4
    • /
    • pp.176-183
    • /
    • 2013
  • In this paper, we report the design, fabrication and characterization of the 3-Dimensional optical receiver for a Laser Detection And Ranging (LADAR) system. The optical receiver is composed of three parts; $16{\pm}16$ Geiger Mode InGaAs Avalanche Photodiode (APD) array device operated at 1560 nm wavelength, Read Out Integrated Circuit (ROIC) measuring the Time-Of-Flight (TOF) of the return signal reflected from target objects, a package and cooler maintaining the proper operational condition of the detector and control electronics. We can confirm that the LADAR system can detect the signal from a target up to 1.2 km away, and it showed low Dark Count Rate (DCR) of less than 140 kHz, and higher than 28%-Photon Detection Efficiency (PDE). This is considered to be the best performance of the $16{\pm}16$ FPA APD optical receiver for a LADAR system.