• Title/Summary/Keyword: phase resolution

Search Result 1,032, Processing Time 0.033 seconds

Low-Power, All Digital Phase-Locked Loop with a Wide-Range, High Resolution TDC

  • Pu, Young-Gun;Park, An-Soo;Park, Joon-Sung;Lee, Kang-Yoon
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.366-373
    • /
    • 2011
  • In this paper, we propose a low-power all-digital phase-locked loop (ADPLL) with a wide input range and a high resolution time-to-digital converter (TDC). The resolution of the proposed TDC is improved by using a phase-interpolator and the time amplifier. The phase noise of the proposed ADPLL is improved by using a fine resolution digitally controlled oscillator (DCO) with an active inductor. In order to control the frequency of the DCO, the transconductance of the active inductor is tuned digitally. The die area of the ADPLL is 0.8 $mm^2$ using 0.13 ${\mu}m$ CMOS technology. The frequency resolution of the TDC is 1 ps. The DCO tuning range is 58% at 2.4 GHz and the effective DCO frequency resolution is 0.14 kHz. The phase noise of the ADPLL output at 2.4 GHz is -120.5 dBc/Hz with a 1 MHz offset. The total power consumption of the ADPLL is 12 mW from a 1.2 V supply voltage.

Fast Ambiguity Resolution using Galileo Multiple Frequency Carrier Phase Measurement

  • Ji, Shengyue;Chen, Wu;Zhao, Chunmei;Ding, Xiaoli;Chen, Yongqi
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.179-184
    • /
    • 2006
  • Rapid and high-precision positioning with a Global Navigation Satellite System (GNSS) is feasible only when very precise carrier-phase observations can be used. There are two kinds of mathematical models for ambiguity resolution. The first one is based on both pseudorange and carrier phase measurements, and the observation equations are of full rank. The second one is only based on carrier phase measurement, which is a rank-defect model. Though the former is more commonly used, the latter has its own advantage, that is, ambiguity resolution will be freed from the effects of pseudorange multipath. Galileo will be operational. One of the important differences between Galileo and current GPS is that Galileo will provide signals in four frequency bands. With more carrier-phase data available, frequency combinations with long equivalent wavelength can be formed, so Galileo will provide more opportunities for fast and reliable ambiguity resolution than current GPS. This paper tries to investigate phase only fast ambiguity resolution performance with four Galileo frequencies for short baseline. Cascading Ambiguity Resolution (CAR) method with selected optimal frequency combinations and LAMBDA method are used and compared. To validate the resolution, two tests are used and compared. The first one is a ratio test. The second one is lower bound success-rate test. The simulation test results show that, with LAMBDA method, whether with ratio test or lower bound success rate validation criteria, ambiguity can be fixed in several seconds, 8 seconds at most even when 1 sigma of carrier phase noise is 12 mm. While with CAR method, at least about half minute is required even when 1 sigma of carrier phase noise is 3 mm. It shows that LAMBDA method performs obviously better than CAR method.

  • PDF

Super Resolution Image Reconstruction Using Phase Correlation Based Subpixel Registration from a Sequence of Frames (위상 상관(Phase Correlation)기반의 부화소 영상 정합방법을 이용한 다중 프레임의 초해상도 영상 복원)

  • Seong, Yeol-Min;Park, Hyun-Wook
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.481-484
    • /
    • 2005
  • Inherent opportunities on research for restoring high resolution image from low resolution images are increasing in these days. Super resolution image reconstruction is the process of combining multiple low resolution images to form a higher resolution one. To achieve super resolution reconstruction, proper observation model which is based on subpixel shift information is required. In this context, the importance of the subpixel registration cannot be estimated because subpixel shift information cannot be obtained from original image. This paper presents a regularized adaptive super resolution reconstruction method based on phase correlated subpixel registration, where the Constrained Least Squares(CLS) Restoration is adopted as a post process.

  • PDF

Improved Lateral Resolution of Interferometric Microscope Using Precision Scanner (정밀 스캐너를 이용한 간섭 현미경의 가로방향 분해능 향상)

  • 박성림;박도민;류재욱;권대갑
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.6
    • /
    • pp.116-123
    • /
    • 1998
  • An interferometric microscope with an improved lateral resolution is presented. The nanometer resolution XY stage is integrated into standard temporal phase shifting interferometer. The nanometer resolution XY stage is used to position specimen in subpixel of CCD detector, therefore CCD detector's sampling is improved. Two scanning algorithms and those simulation results are also presented. The simulation results show that scanning algorithms improve CCD detector's sampling significantly, and interferometeric microscope's lateral resolution is improved also.

  • PDF

High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers. (헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정)

  • 김승우;김민석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.203-206
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state-of-the-art reaches the region of sub-nanometers. We propose a new scheme of phase-measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with electrically generated reference signal. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special from of frequency up-down counting technique is combined with the super-heterodyning. This alloys performing required phase unwrapping simply by using programmable digital gates without 2$\pi$ ambiguities up to the maximum velocity of 2.35 m/s.

  • PDF

Resolution of Aryl α-Aminoalkyl Ketones on a Doubly Tethered Liquid Chromatographic Chiral Stationary Phase Based on (+)-(18-Crown-6)-2,3,11,12-tetracarboxylic Acid

  • Jin, Kab-Bong;Kim, Hee-Jin;Hyun, Myung-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.5
    • /
    • pp.751-755
    • /
    • 2011
  • A doubly tethered chiral stationary phase (CSP) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was applied to the resolution of various aryl ${\alpha}$-aminoalkyl ketones with the use of 80% ethanol in water containing 10 mM sulfuric acid as a mobile phase. The chiral resolution was quite successful, the separation factors (${\alpha}$) and the resolutions ($R_S$) being in the range of 1.39-2.05 and 3.18-5.22, respectively. The separation factors (${\alpha}$) on the doubly tethered CSP were slightly worse than those on the corresponding singly tethered CSP. However, the resolutions ($R_S$) on the doubly tethered CSP were generally greater than those on the corresponding singly tethered CSP. The chromatographic behaviors for the resolution of aryl ${\alpha}$-aminoalkyl ketones on the doubly tethered CSP were demonstrated to be dependent on the type and the content of the organic and acidic modifiers in aqueous mobile phase and the column temperature.

Effect of Mobile Phase Additive on Enantiomer Resolution for Chiral Amines on Polysaccharide-derived Chiral Stationary Phases by High Performance Liquid Chromatography (고성능 액체크로마토그래피의 다당유도체를 기초로 한 키랄 고정상에서 이동상 첨가제가 키랄 아민의 광학분리에 미치는 영향)

  • Paik, Man-Jeong;Yoon, Hye-Ran;Lee, Wonjae
    • KSBB Journal
    • /
    • v.29 no.3
    • /
    • pp.205-209
    • /
    • 2014
  • Chromatographic enantiomer resolution of chiral amines was performed on several covalently immobilized and coated chiral stationary phases (CSPs) based on polysaccharide derivatives under the mobile phase conditions containing base or acid or acid/base additive. The chromatographic parameters including separation factors and capacity factors were greatly influenced by the nature of the mobile phase containing base or acid or salt additive as well as the used CSPs. When 0.05% triethylamine/0.05% trifluoroacetic acid as an additive in the mobile phase was used on all CSPs in this study, the greatest enantiomer resolution was observed except for Chiralpak AD. Also, it was shown that the change of base additive into acid or salt in the mobile phase may directly affect chiral recognition mechanisms between the chiral selectors and analytes occurring during enantiomer separation, resulting in the change of elution orders.

High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers (헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정)

  • Kim, Min-Seok;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.9
    • /
    • pp.172-178
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state -of-the-art reaches the region of sub-nanometers. So far, the demand has been met by increasing the clock speed that drives the electronics involved fur the phase measurement of the Doppler shift, but its further advance is being hampered by the technological limit of modem electronics. To cope with the problem, in this investigation, we propose a new scheme of phase -measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with a stable reference signal generated from a special phase- locked-loop. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special form of frequency up-down counting technique is combined with the super-heterodyning. This allows performing required phase unwrapping simply by using programmable digital gates without 2n ambiguities up to the maximum velocity guaranteed by the original beat frequency.

Effect of Phase Error on the Lateral Resolution of Reconstruction Image in Incoherent Triangular Holography (인코히어런트 삼각 홀로그래피에서 위상오차가 횡축방향의 해상도에 미치는 영향에 관한 연구)

  • Kim, Soo-Gil
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.1-6
    • /
    • 2013
  • It is introduced the phase error sources of a incoherent hologram in incoherent triangular holography and derived the reconstruction image of point-source including the phase error in the lateral direction. From the reconstruction image of point-source, we analyzed the effect of phase error on the lateral resolution. When the phase retardation errors and azimuth angle error of a wave plate and a polarizer range from 0 to $2{\pi}/15$, the normalized intensities of reconstructed images are down by about 0.1% and 2.3%, respectively.

Analysis of success rate of GPS carrier phase ambiguity resolution in Korea peninsula

  • Soo, Son-Ji;In, Jee-Gyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.114.1-114
    • /
    • 2001
  • GPS Receiver gives pseudorange Doppler and integrated carrier phase for measurements to compute navigation information. Thought the integrated carrier phase can be transfer to the equal domain as pseudorange by multiplying the wave length of the received signal, in order to get position information from the carrier phase measurements the integer ambiguity should be resolved. And differencing technique is generally used to eliminate the common error terms of the integrated carrier phase measurements between robber and server. In short baseline double-differencing operation has effect on elimination the common biases for both stations and thus ambiguity resolution are to be reliable. But the baseline increases, the integer ambiguity resolution is hardly, due to the correlated common error is increase ...

  • PDF