• 제목/요약/키워드: perfobond rib

검색결과 33건 처리시간 0.025초

원형강관에 부착된 ㄱ형 perfobond 리브 전단연결재의 정적실험 (Static Tests of ㄱ Type Perfobond Rib Shear Connectors when using Steel Tube)

  • 이흥수;정철헌;최외호;김석기;유성근;김영호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.778-781
    • /
    • 2004
  • This paper summarizes the results of push-out test specimens with a new type of shear connector called ㄱ type perfobond rib. This connector is a flat steel plate with a number of holes punched through and strengthen rib's head part. According to experiment result, ㄱ type perfobond rib shear connector appeared that resistance force is increased than stud shear connector by $108\%$ and perfobond rib shear connector by $26\%$. The results obtained indicate that the perfobond rib connector is a viable alternative to the headed studs. An appreciable improvement in the shear capacity of the connection was observed when additional reinforcing bars were passed through the perfobond rib holes. For composite beams with concrete filled steel tubes, ㄱ type perfobond shear connectors exhibit adequate ductility and substantially higher capacities.

  • PDF

Perfobond rib 전단연결재가 설치된 강.콘크리트 합성보의 정적거동 (Static Behavior of Steel-Concrete Composite Beam with Perfobond Rib Shear Connector)

  • 안진희;정하민;김상효
    • 한국강구조학회 논문집
    • /
    • 제21권4호
    • /
    • pp.421-432
    • /
    • 2009
  • 본 연구는 perfobond rib 전단연결재를 사용한 합성보의 정적거동 특성을 파악하기 위하여 perfobond rib 전단연결재의 push-out 실험과 perfobond rib 전단연결재를 설치한 합성보의 하중재하 실험을 실시하였다. Perfobond rib의 전단저항성능은 콘크리트 강도 증가에 의한 콘크리트 선단지지력 및 콘크리트 다웰의 전단저항 성능 증가로 콘크리트 강도에 비례하며 횡방향 철근의 휨변형 성능에 대한 제한으로 연성효과를 나타내는 상대슬립은 일정 콘크리트 강도이상에서는 증가하지 않았다. 합성보의 하중재하 실험결과, 합성보에 휨 하중과 휨 전단하중이 동시에 작용하게 되므로 rib 홀에 배치된 횡방향 철근과 콘크리트 다웰부의 전단저항에 따라 합성보 콘크리트 슬래브의 rib 홀의 위치에서 횡방향 균열이 발생하였으며, perfobond rib 배치방법에 따라 합성단면 경계에서의 상대변위로 강성전단연결재의 전단거동 특성을 확인하였다. Perfobond rib와 같이 합성보에 대한 전단저항 성능이 큰 강성 전단연결재의 경우 전단연결재에 의한 합성보의 거동이 변화하므로 합성보 단면설계시 이에 대한 고려가 필요하다.

파형전단연결재의 전단저항 성능 (Shear Capacity of Corrugated rib Shear Connector)

  • 안진희;최규태;김성현;김상효
    • 대한토목학회논문집
    • /
    • 제28권3A호
    • /
    • pp.375-381
    • /
    • 2008
  • 본 연구는 기존의 perfobond rib을 절곡시켜 변형시킨 형태인 corrugated rib 전단연결재의 전단강도를 평가하기 위하여 push-out 실험을 통하여 기존의 전단연결재인 stud, perfobond rib 전단연결재와 비교하였다. Corrugated rib 전단연결재의 전단강도에 기여하는 요인인 홀의 유무, 관통철근의 유무, 파형의 파고, rib의 높이 등을 고려하여 총 12본의 push-out 시험체를 제작하였다. 실험결과 corrugated rib 전단연결재 시험체는 콘크리트 슬래브의 지압성 파괴에 의하여 파괴 모드가 결정되었으며, 용접부의 파괴는 발생하지 않았다. 또한 corrugated rib 전단연결재가 perfobond rib 전단연결재보다 최대 96%의 전단저항 성능이 향상됨을 확인하였고, 관통철근의 배근유무에 따라 48%의 전단강도가 증가하는 것으로 나타났다. Corrugated rib 전단연결재의 홀 및 관통철근에 의해 콘크리트 다웰 효과가 증가되었으며, 파형의 파고 및 rib의 높이가 증가할수록 콘크리트 지압저항 영역의 증가로 인하여 전단강도가 증가하는 것을 확인할 수 있었다.

합성작용을 위한 새로운 Perfobond T형 전단연결재 (A New T Type Perfobond Shear Connector for Composite Action)

  • 정철헌;김종석;심창수;김광수;정광회;심정욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.293-296
    • /
    • 2006
  • The results and interpretations of push-out tests on shear connector devices for composite bridges carried out in this study are presented. The devices under investigations are headed studes, perfobond rib, ㄱtype perfobond rib, T- Connector and a new type of shear connector called T type perfobond rib. This new connector is flat steel plate with a number of holes punched through. The results obtained indicate that the T type perfobond rib shear connectors exhibit adequate ductility and substantially higher capacities. Therefore for composite beams utilizing reinforced concrete slabs, the T type perfobond rib shear connectors is a viable alternative to the headed studs.

  • PDF

Perfobond Rib 전단연결재를 사용한 실험체의 전단강도 분석 (Analysis on Shear Force of Specimens Using Perfobond Rib Shear Connector)

  • 최진웅;박병건;김형준;정호성;박선규
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권1호
    • /
    • pp.138-147
    • /
    • 2011
  • 본 연구의 목적은 직접전단응력 및 휨 전단응력의 비교분석을 통하여 Perfobond Rib 전단연결재를 사용한 구조물의 하중방향에 따른 전단응력 분석이다. 직접전단응력 분석을 위해서 5개의 변수로 Perfobond Rib 전단연결재 실험체 5개를 제작하고 Push-out Test를 실시하였다. 실험 후 Perfobond Rib 전단연결재의 전단저항 메커니즘을 규명하고, 직접전단응력에 영향을 미치는 주요 인자를 바탕으로 직접전단력을 산출할 수 있는 제안식을 제시하였다. 또한 휨 전단응력의 분석을 위해 강-콘크리트 합성 바닥판 실험체를 제작하고 정적 휨실험을 실시하였다. 정적 휨실험을 바탕으로 휨 거동특성을 분석하고 휨 전단응력을 계산하였다. 직접전단응력과 EN 1994-1-1을 통해 계산된 휨 전단응력을 비교하여 하중방향에 따른 전단저항응력에 대해서 분석을 하였다.

ㄱ형 Perfobond 리브 전단연결재의 적용성 평가 (Applicability Evaluation of ㄱ Type Perfobond Rib Shear Connectors)

  • 이흥수;정철헌;김병석;강재윤;손유식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.410-413
    • /
    • 2006
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. The ㄱ type perfobond rib shear connector with safety factor of 3 is applied shear connector of CFT composite girder. From static test result of CFT composite girder, relative displacement of 0.01mm measured at the service load moment. At design of the ㄱ type perfobond rib shear connector, applying safety factor of 3 was more conservative than test result.

  • PDF

ㄱ형 perfobond 리브 전단열결재의 정적 강도평가식 (Static Strength Evaluation Equations of ㄱType Perfobond Rib Shear Connectors)

  • 이흥수;정철헌;손유식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.451-454
    • /
    • 2005
  • The ㄱ type perfobond rib shear connector is a ㄱ type flat steel plate with a number of holes punched through. This connector can be effectively used in girder with high shear. The ㄱ type perfobond rib shear connector exhibit very stiff behaviour under service load conditions and also had the characteristic of retaining a significant amount of load after the attainment of ultimate capacity. A regression analysis, which is based on a model that takes into account the contributions of concrete dowels formed by the rib holes, the transverse reinforcement, the strength of concrete in front of the rib, and the ㄱ type plate as well as a nonlinear finite element analysis, is used in the derivation. An empirical equation for the design of ㄱ type perfobond rib shear connector is proposed.

  • PDF

Perfobond rib을 적용한 PSC-강 복합구조 연결부 거동에 대한 실험적 연구 (An Experimental Study for Joints in Hybrid PSC-Steel Beam with Perfobond rib)

  • 원정훈;박세준;윤지현;김상효;이찬구;김성재
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.17-20
    • /
    • 2008
  • 본 연구에서는 강-프리스트레스트 콘크리트(PSC) 복합 보의 연결부 거동과 시공성을 향상시키기 위해 perfobond rib를 적용한 연결부를 제안하였으며, 보 실험을 통해 제안된 연결부의 성능을 검증하였다. 강 플레이트 상 하면에 perfobond rib로 이루어진 연결부를 이용하여 중앙에 위치한 강형부와 지점에 위치한 PSC형부를 연결한 3.9m 길이의 보 실험체 3개를 제작하여 재하실험을 수행하였다. 재하실험 결과, 제안된 연결부를 갖는 보 실험체는 PSC형부의 파괴에 의해 전체 보 부재의 파괴와 극한강도가 지배된다. 또한, 균열의 진전형상과 초기강도, 극한강도 도달까지의 하중저항능력을 분석한 결과, perfobond rib를 적용한 연결부는 기존의 stud를 적용한 연결부만큼 구조적으로 우수한 것으로 판단된다.

  • PDF

FRP-콘크리트 합성을 위한 퍼포본드 전단 연결재의 성능 평가 (Performance Evaluation of Perfobond Rib FRP Shear Connectors for Composition between FRP and Concrete)

  • 박성용;조정래;황훈희;조근희;백동열;김성태
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.297-300
    • /
    • 2006
  • One of main issues of the FRP-concrete composite member is shear connection between FRP and concrete in order to secure composite behavior of FRP and concrete. To solve this problem, perfobond rib FRP shear connector is introduced for the mechanical shear connection. In this study, experimental study was carried out on the perfobond rib FRP shear connectors in order to develop the effective details of perfobond rib FRP shear connectors. Pull-out test specimens were manufactured with FRP plate with holes embedded in concrete block. Main parameters considered in this study were diameter of holes, ratio of spacing between the centres of holes to the diameter of holes, and thickness of FRP plates. Test results are discussed according to above parameters compared with other empirical expressions for steel perfobond rib connector.

  • PDF

초고성능 콘크리트에 대한 Perfobond Rib 전단연결재 거동 평가 (Evaluation of Shear Strength of Perfobond Rib in Ultra High Performance Concrete)

  • 강재윤;정우태
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.5015-5020
    • /
    • 2015
  • 기존에 제안된 Perfobond rib connector의 강도평가식은 압축강도가 약 50 MPa 이하의 콘크리트 강도 범위에 대한 Push-out test의 결과로 유도된 것으로서, 압축강도 80 MPa 이상의 초고성능 콘크리트에 대한 전단 연결재 성능 평가를 위하여 Perfobond rib 연결재의 전단강도를 파악하기 위한 Push-out test를 수행하였다. Perfobond rib connector의 제작변수는 관통홀의 지름 및 개수이며, 강섬유가 혼입된 180 MPa의 콘크리와 강섬유를 혼입하지 않은 압축강도 80 MPa의 콘크리트를 적용하여 콘크리트 강도 변화에 대한 전단강도 변화를 검토하였다. 실험결과, 콘크리트 강도와 홀의 개수가 증가함 따라 전단강도가 증가하며, 다웰 효과에 의한 전단강도 증가율도 큰 것으로 나타났다. 기존에 다른 연구자들이 제안한 강도식으로 계산된 예측치와 비교한 결과, 실험값은 Oguejiofor & Hosain[2]이 제안한 강도식에 근접한 결과를 보였다.