• Title/Summary/Keyword: peak set

Search Result 592, Processing Time 0.028 seconds

Effect of thread design on the marginal bone stresses around dental implant (임플란트 나사산 디자인이 변연골 응력에 미치는 영향)

  • Lee, Sang-Hyun;Jo, Kwang-Heon;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.316-323
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the effect of different thread designs on the marginal bone stresses around dental implant. Materials and methods: Standard ITI implant(ITI Dental Implant System; Straumann AG, Waldenburg, Switzerland), 4.1 mm in diameter and 10 mm in length, was selected as control. Test implants of four different thread patterns were created based on control implant, i.e. maintaining all geometrical design of control implant except thread pattern. Four thread designs used in test implants include (1) small V-shape screw (model A), (2) large V-shape screw (model B), (3) buttress screw (model C), and (4) trapezoid screw (model D). Surface area for unit length of implant was 14.4 $mm^2$ (control), 21.7 (small V-shape screw), 20.6 (large V-shape screw), 17.0 (buttress screw) and 28.7 $mm^2$ (trapezoid screw). Finite element models of implant/bone complex were created using an axisymmetric scheme with the use of NISA II/DISPLAY III (Engineering Mechanics Research Corporation, Troy, MI, USA). A load of 100 N applied to the central node on the crown top either in parallel direction or at 30 degree to the implant axis (in order to apply non-axial load to the implant NKTP type 34 element was employed). Quantification and comparison of the peak stress in the marginal bone of each implant model was made using a series of regression analyses based on the stress data calculated at the 5 reference points which were set at 0.2, 0.4, 0.6, 0.8 and 1.0 mm from implant wall on the marginal bone surface. Results: Results showed that although severe stress concentration on the marginal bone cannot be avoided a substantial reduction in the peak stress is achievable using different thread design. The peak marginal bone stresses under vertical loading condition were 7.84, 6.45, 5.96, 6.85, 5.39 MPa for control and model A, B, C and D, respectively. And 29.18, 26.45, 25.12, 27.37, 23.58 MPa when subject to inclined loading. Conclusion: It was concluded that the thread design is an important influential factor to the marginal bone stresses.

Characteristics of the Maximum Glow Intensity According to the Thermoluminescent Phosphors used in the Absorbed Dose Measurement of the Radiation Therapy (방사선치료 선량 측정에 사용되는 열형광체에 따른 최대 형광 강도 특성)

  • Kang, Suman;Im, Inchul;Park, Cheolwoo;Lee, Mihyeon;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • The purpose of this study were to analyze the characteristic of the glow curves in order to the glow temperature of the thermoluminescent dosimeters (TLDs) for the absorbed dose measurement of the radiation therapy. In this study, we was used the TLDs of the LiF:Mg${\cdot}$Ti, LiF:Mg${\cdot}$Cu${\cdot}$P, $CaF_2$:Dy, $CaF_2$:Mn (Thermo Fisher Scientific Inc., USA). The source-to-solid dry phantom (RW3 slab, IBA Dosmetry, Germany) surface distance was set at 100 cm, and the exposure dose of 100 MU (monitor unit) was used 6- and 15-MV X-rays, and 6- and 12-MeV electron beams in the reference depth, respectively. After the radiations exposure, we were to analyze the glow curves by using the TL reader (Hashaw 3500, Thermo Fisher Scientific Inc., USA) at the fixed heating rate of $15^{\circ}C/sec$ from $50^{\circ}C$ to $260^{\circ}C$. The glow peaks, the trapping level in the captured electrons and holes combined with the emitted light, were discovered the two or three peak. When the definite increasing the temperature of the TLDs, the maximum glow peak representing the glow temperature was follow as; $LiF:Mg{\cdot}Ti$: $185.5{\pm}1.3^{\circ}C$, $LiF:Mg{\cdot}Ti$: $135.0{\pm}5.1^{\circ}C$, $CaF_2$:Dy: $144.0{\pm}1.6^{\circ}C$, $CaF_2$:Mn: $294.3{\pm}3.8^{\circ}C$, respectively. Because the glow emission probability of the captured electrons depend on the heating temperature after the exposure radiation, TLDs by applying the fixed heating rate, the accuracy of measurement will be able to improve within the absorbed dose measurement of the radiation therapy.

Spawning Volumes and Times of Blue Devil Pomacentrus caeruleus (파랑점자돔, Pomacentrus caeruleus의 산란주기 및 산란량)

  • Jung, Min-Min;Oh, Bong-Sae;Kim, Sam-Yeon;Lee, Chang-Hoon;Yang, Moon-Ho;Han, Seok-Jung;Rho, Sum;Kim, Hyeung-Sin
    • Korean Journal of Ichthyology
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 2010
  • Blue devil (Pomacentrus caeruleus, also called Chrysiptera cyanea) is widespread in the Indo-Pacific Ocean and very popular all over the world as an aquarium fish because it is so easy to keep in a marine aquarium. However, tank-breeding techniques are not completely known. In this study, we reared blue devil and investigated its spawning ecology, as a necessary precursor for successful artificial-tank breeding. We investigated the spawning volume according to time with two types of calendars: solar and lunar. Rearing conditions were set at 30 ppt salinity, $27^{\circ}C$ water temperature, in two aquariums with water volumes of 80 and 125 L. We successfully bred P. caeruleus in this artificial-tank system. The aquarium fish formed a spawning harem with one male and more than two females. We harvested about 113,580 eggs in 44 spawning episodes by two spawning harems during the 11-month period from December to October. They showed a peak season of spawning volume and time in May and June. We confirmed the two peak points in spawning volumes and times, which coincided with the first quarter and last (third) quarter of the lunar phases of the moon.

Factors Influencing Frequency of Abnormal Peak in the Measurement of HbA1c by HPLC (HPLC법을 이용한 HbA1c 측정시 Abnormal Peak의 빈도와 원인)

  • Kim, Sun-Kyung;Bae, Ae-Young;Choi, Dae-Yong;Kim, Myung-Soo;Yoo, Kwang-Hyun;Ki, Chang-Seok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.2
    • /
    • pp.71-77
    • /
    • 2005
  • We experienced the specimen that contains a hemoglobin variant known as interference from HbAS in October 2003. It was the first case of Hb variants since Samsung Medical Center began conducting glycohemoglobin College of American Pathologists surveys in 1997. The purpose of this study is to share our experience with the specimen and promote the understanding of Hb variants & derivatives. We've performed cross checks to examine HbA1c by using two pieces of equipment; the TOSHOH G7 and BIO-RAD VARIANT-T(turbo), and Automatic High Performance Liquid Chromatography(HPLC) as an analytic measurement method. HPLC provides different fractional information of hemoglobin with a two-dimensional graph as well as numeric results. We have been performing a "Systematic Checking Process". Three specimen suspicious of Hb variants & derivatives were found through this process. College of American Pathologists notified that it is important for users to be aware of the limitation of their glycohemoglobin method to avoid reporting incorrect results due to interference from hemoglobin variants or hemoglobin adducts. Therefore, laboratory findings of Hb variants & derivatives are very important. The experience of qualified technicians with professional knowledge in Hb variants is the most important aspect in finding Hb variants. Korea is homogeneous in race and is not in an area with a higher finding rate of Hb variants. While 1,024 cases of Hb variants have been found in Japan, we do not have specific data on how many cases of Hb variants have been found in Korea. Considering Hb variant cases in Japan, which is geographically close to us, it is presumed that there must be various Hb variant cases in Korea. If domestic laboratories set a systemic protocol and build a network to share our experience in Hb variants, I expect the Korean Hb variants could also be listed on the world's Hb variant list.

  • PDF

The Convergence Study on the Effects of Combined Exercise Rehabilitation on Lower limb Muscular function and Cytokines in the Taekwondo players with Patellofemoral Pain Syndrome (무릎넙다리통증증후군 태권도 선수들의 복합 운동재활이 하지 근기능 및 사이토카인의 효과에 관한 융합적 연구)

  • An, Hwan-Pil
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.245-256
    • /
    • 2017
  • The purpose of this study was to determined the converge effects of combined exercise rehabilitation on lower limb muscular function and cytokines in taekwondo player with patellofemoral pain syndrome. In this study, combined exercise rehabilitation(aquatic exercise 3 times a week, resistance exercise 2 times a week) was performed and 20 collegiate taekwondo player with patellofemoral pain syndrome(control group: n=10, combined exercise rehabilitation group: n=10) were participated for 8 weeks. Statistical significance verification was carried out by a two - way ANOVA repeated measures design as a mixture using the SPSS 18.0 program. The statistically significant level was set at 0.05. The results of this study were as following. Peak torque was higher significantly in extensor(p<.001) and flexor(p<.01) at $60^{\circ}/sec$ in the combined exercise rehabilitation group than the control group over combined exercise treatment period. Average power was higher significantly in extensor muscles at $180^{\circ}/sec$ in the combined exercise rehabilitation group than the control group over combined exercise treatment period.(p<.01). The variable of TNF-a was higher significantly in the combined exercise rehabilitation group than the control group as over combined exercise treatment period. Therefore, it can be concluded that a combined exercise rehabilitation program is effective in improving the lower limb muscular function and TNF-a in Patellofemoral Pain Syndrome patient.

Hydrological Characteristics of Subsurface Stormflow through Soil Matrix and Macropores on forested Hillslopes (산지 사면에서 토양체와 대공극을 통해 발생하는 지표하 호우류의 수문학적 특성)

  • Kim, Kyong-Ha
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.777-785
    • /
    • 1997
  • This study was conducted to clarify the hydrological characteristics of subsurface flow through a soil matrix and macropores. The research facility was set up in a 20m-1ong trench excavated down to bedrock at the base of a hillslope in the Panola catchment under USGS Georgia district. 13 macropores were found on the trench face and 6 major macropores were monitored. Matrix and macropore flow were measured during 95.5mm rainfall on March, 6 to 7. 1996. Macropore flow had great influence on formation of peak flow because the delivery time to Peak flow of macropore flow were faster about 10hrs than those of matrix flow. Matrix flow continued to recess for 3 days. On the other hand, macropore flow stopped within 12hrs after the event ceased. This means that matrix flow controls the recession part. The spatial variations of matrix and macropore flow between each trough and collector were very large by a wide range of 8,655.3 $\ell$ to 17.8 $\ell$ . The bed rock surface topography relates closer with the spatial variations of the flow than the surface one.

  • PDF

Predicting Parturition Time through Ultrasonic Measurement of Posture Changing Rate in Crated Landrace Sows

  • Wang, J.S.;Wu, M.C.;Chang, H.L.;Young, M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.5
    • /
    • pp.682-692
    • /
    • 2007
  • This study presents an automatic system to predict parturition time in the crated sows. The system relies on ultrasonic transducers mounted from above along the length of the crate. Using a 40 kHz time of flight (TOF) single envelope wave, the momentary distances between the sensors are measured. Therefore, the local momentary height of the sow and the momentary posture, i.e. standing posture (SDP), kneeling posture (KP), sitting posture (STP) and lateral lying posture (LLP) are determined. Crated sows change their postures from standing to lying and vice versa which follows a characteristic pattern. As parturition approaches, sows exhibit uneasiness, restlessness and the stand up sequence (SUS, the posture transition from LLP to SDP) rate increases because of labor pains. In time series, the SUS rate demonstrates a peak and it happens approximately 0-12 h before parturition. In this paper, the basic parturition threshold value method (BPTVM) and the same hour method (SHM) are proposed for predicting parturition, both of which are based on the SUS rate. The BPTVM mainly detects the peak of the SUS rate. As the SUS rate exceeds the threshold value, the parturition becomes predictable. Moreover, the SHM calculates the difference in the SUS rates between a particular time of day and the corresponding time of the preceding day. Compared to the BPTVM, the SHM can eliminate the circadian rhythm of the SUS rate influenced by feeding behavior. Using the SHM the parturition can be approximately predicted within hours. In an attempt to define the threshold parameters of predicting parturition, a data set with 32 sows of the SUS rate are used to estimate assumable predicting probability. The results show the assumable probability of the parturition prediction within 9 h is 96.9% for the SHM and 84.4% for the BPTVM. Moreover, the SHM can even reach a 75% probability of prediction within three hours of parturition. We conclude that the SHM is more accurate and is more useful for parturition time prediction. When parturition is detected, the proposed algorithm generates a warning signal which can inform human personnel to protect the mother and newborn piglets.

Analysis of Stormwater Runoff Characteristics for Spatial Distribution of LID Element Techniques using SWMM (SWMM 모형을 이용한 LID 요소기술의 공간적 분포에 따른 우수유출특성 분석)

  • Yeon, Jong Sang;Jang, Young Su;Lee, Jae Hyuk;Shin, Hyun Suk;Kim, Eung Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3983-3989
    • /
    • 2014
  • As the storm water runoff characteristics in urban areas have changed owing to urbanization, centralized facilities to reduce the urban flood runoff had been implemented. On the other hand, because they have their limitations, LID (Low Impact Development) of the distributed facilities for storm water runoff reduction is being actively planned and applied. The purpose of this study was to analyze the runoff characteristics for the spatial distribution of typical LID element techniques. This study set a study basin consisting of the five subbasins with the same basin and drainage systems, and analyzed the flood runoff characteristics from the two scenarios, one is for the locations and the other is for the number of green roofs (GR) and permeable pavement (PP), respectively, selected as typical LID element techniques. The SWMM implementation results showed that GR reduces 11.07% of the total and 3.42% of the peak amounts of storm water runoff, and PP leads to 18.09% of the total and 17.94% of the peak discharge reduction for a subbasin. Such a reduction rate is constant regardless of the LID locations, and increases linearly with the number of LID applications. The different runoff reduction rates between the GR and PP applications appear to be due to the effects of the different hydraulic conductivities in the control parameters for each LID.

Determining Transit Vehicle Dispatching Time (최적 배차시각 설정에 관한 해석적 연구)

  • Park, Jun-Sik;Go, Seung-Yeong;Kim, Jeom-San;Gwon, Yong-Seok
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.3
    • /
    • pp.137-144
    • /
    • 2007
  • This study involves an analytical approach to determine transit dispatching schedules (headways) Determining a time schedule is an important process in transit system planning. In general, the transit headway should be shorter during the peak hour than at non-peak hours for demand-responsive service. It allows passengers to minimize their waiting time under inelastic, fixed demand conditions. The transit headway should be longer as operating costs increase, and shorter as demand and waiting time increase. Optimal headway depends on the amount of ridership. and each individual vehicle dispatching time depends on the distribution of the ridership. This study provides a theoretical foundation for the dispatching scheme consistent with common sense. Previous research suggested a dispatching scheme with even headway. However, according to this research, that is valid for a specific case when the demand pattern is uniform. This study is a general analysis expanding that previous research. This study suggests an easy method to set a time table without a complex and difficult calculation. Further. if the time axis is changed to the space axis instead, this study could be expanded to address the spacing problems of some facilities such as roads. stations, routes and others.

A CMOS Image Sensor with Analog Gamma Correction using a Nonlinear Single Slope ADC (비선형 단일 기울기 ADC를 사용하여 아날로그 감마 보정을 적용한 CMOS 이미지 센서)

  • Ham Seog-Heon;Han Gunhee
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.1 s.343
    • /
    • pp.65-70
    • /
    • 2006
  • An image sensor has limited dynamic range while the human eye has logarithmic response over wide range of light intensity. Although the sensor gain can be set high to identify details in darker area on the image, this results in saturation in brighter area. The gamma correction is essential to fit the human eye response. However, the digital gamma correction degrades image quality especially for darker area on the image due to the limited ADC resolution and the dynamic range. This Paper proposes a CMOS image sensor (CIS) with a nonlinear analog-to-digital converter (AU) which performs analog gamma correction. The CIS with the proposed nonlinear analog-to-digital conversion scheme was fabricated with a $0.35{\mu}m$ CMOS process. The analog gamma correction using the proposed nonlinear ADC CIS provides the 2.2dB peak-signal-to-noise-ratio(PSM) improved image qualify than conventional digital gamma correction. The PSNR of the image obtain from the digital gamma correction is 25.6dB while it is 27.8dB for analog gamma correction. The PSNR improvement over digital gamma correction is about $28.8\%$.