1 |
Lin S, Shi S, LeGeros RZ, LeGeros JP. Three-dimensional finite element analyses of four designs of a high-strength silicon nitride implant. Implant Dent 2000;9:53-60.
DOI
ScienceOn
|
2 |
Misch CE. Implant design considerations for the posterior regions of the mouth. Implant Dent 1999;8:376-86.
DOI
ScienceOn
|
3 |
Misch CE, Bidez MW, Sharawy M. A bioengineered implant for a predetermined bone cellular response to loading forces. A literature review and case report. J Periodontol 2001;72:1276-86.
DOI
ScienceOn
|
4 |
Misch CE, Poitras Y, Dietsh-Misch F. Endosteal Implants in the Edentulous Posterior Maxilla: Rationale and Clinical Report. Oral Health 2000;8:7-16.
|
5 |
Bidez MW, Misch CE. Force transfer in implant dentistry: basic concepts and principles. J Oral Implantol 1992;18:264-74.
|
6 |
Rieger MR, Adams WK, Kinzel GL. A finite element survey of eleven endosseous implants. J Prosthet Dent 1990;63:457-65.
DOI
ScienceOn
|
7 |
Chun HJ, Cheong SY, Han JH, Heo SJ, Chung JP, Rhyu IC, Choi YC, Baik HK, Ku Y, Kim MH. Evaluation of design parameters of osseointegrated dental implants using finite element analysis. J Oral Rehabil 2002;29:565-74.
DOI
ScienceOn
|
8 |
O Brien GR, Gonshor A, Balfour A. A 6-year prospective study of 620 stress-diversion surface (SDS) dental implants. J Oral Implantol 2004;30:350-7.
DOI
ScienceOn
|
9 |
Gotfredsen K, Berglundh T, Lindhe J. Bone reactions adjacent to titanium implants with different surface characteristics subjected to static load. A study in the dog (II). Clin Oral Implants Res 2001;12:196-201.
DOI
ScienceOn
|
10 |
Misch CE. Dental implant prosthetics. St Louis, Mosby, 2005. pp. 322-47.
|
11 |
Kong L, Hu K, Li D, Song Y, Yang J, Wu Z, Liu B. Evaluation of the cylinder implant thread height and width: a 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2008;23:65- 74.
|
12 |
Seo YH, Vang MS, Yang HS, Park SW, Park HO, Lim HP. Threedimentional finite element analysis of stress distribution for different implant thread slope. J Korean Acad Prosthodont 2007;45:482-91.
|
13 |
Hansson S, Werke M. The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. J Biomech 2003;36:1247-58.
DOI
ScienceOn
|
14 |
Yu W, Jang YJ, Kyung HM. Combined influence of implant diameter and alveolar ridge width on crestal bone stress: a quantitative approach. Int J Oral Maxillofac Implants 2009;24:88-95.
|
15 |
Brunski JB, Puleo DA, Nanci A. Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants 2000;15:15- 46.
|
16 |
Geng JP, Ma QS, Xu W, Tan KB, Liu GR. Finite element analysis of four thread-form configurations in a stepped screw implant. J Oral Rehabil 2004;31:233-9.
DOI
ScienceOn
|
17 |
Kong L, Liu B, Li D, Song Y, Zhang A, Dang F, Qin X, Yang J. Comparative study of 12 thread shapes of dental implant designs: a three-dimensional finite element analysis. World J Model Simul 2006;2:134-40.
|
18 |
Sevimay M, Turhan F, Kiliçarslan MA, Eskitascioglu G. Threedimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. J Prosthet Dent 2005;93:227-34.
DOI
ScienceOn
|
19 |
Papavasiliou G, Kamposiora P, Bayne SC, Felton DA. 3DFEA of osseointegration percentages and patterns on implant-bone interfacial stresses. J Dent 1997;25:485-91.
DOI
ScienceOn
|
20 |
Langer B, Langer L, Herrmann I, Jorneus L. The wide fixture: a solution for special bone situations and a rescue for the compromised implant. Part 1. Int J Oral Maxillofac Implants 1993; 8:400-8.
|
21 |
Schrotenboer J, Tsao YP, Kinariwala V, Wang HL. Effect of microthreads and platform switching on crestal bone stress levels: a finite element analysis. J Periodontol 2008;79:2166-72.
DOI
ScienceOn
|
22 |
Lee JH, Frias V, Lee KW, Wright RF. Effect of implant size and shape on implant success rates: a literature review. J Prosthet Dent 2005;94:377-81.
DOI
ScienceOn
|
23 |
Yoon H, Jung UW, Lee J, Kim CS, Kim J, Cho KS, Kim CK, Cho S. Contact non-linear finite element model analysis of initial stability of mini implant. J Korean Acad Periodontol 2007;37: 681-90.
DOI
|
24 |
Himmlova L, Dostalova′T, KacovskyA, Konvickova S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent 2004;91:20-5.
DOI
ScienceOn
|
25 |
Holmgren EP, Seckinger RJ, Kilgren LM, Mante F. Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter, implant shape, and load direction. J Oral Implantol 1998;24:80-8.
DOI
ScienceOn
|