• Title/Summary/Keyword: peak heat release

Search Result 101, Processing Time 0.025 seconds

Fire Characteristics of Composites for Interior Panels Using Cone calorimeter (콘칼로리미터를 이용한 내장판용 복합재료의 화재특성)

  • 이철규;정우성;이덕희
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.55-59
    • /
    • 2004
  • Composite materials were used widely due to merit of light weight, low maintenance cost and easy installation. But it is the cause of enormous casualties to men and properties because of weak about the fire. Particularly, it is more serious in case of subway train installed composite materials. For this reason, experimental comparison has been done fur measuring heat release rate(H.R.R) and smoke production rate(S.P.R) of interior panels of electric motor car using cone calorimeter. A high radiative heat flux of 50kW/㎡ was used to bum out all materials and to simulate the condition of fully developed fire case in the tests. It was observed that Heat Release Rate and Smoke Production Rate curves were dependent on the kinds of the interior materials. From the heat release rate curves, the sustained ignition time, peak heat release rate and total heat release rate were deduced, These data are useful in classifying the materials by calculating two parameters describing the possibility to flashover.

A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux (건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구)

  • Park, Youngju;Kim, Youngtak
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.

Fire Characteristics of Plastic Insulating Materials from Cone Calorimeter Test (콘칼로리미터를 이용한 플라스틱 단열재의 화재특성)

  • 이근원;김관응
    • Fire Science and Engineering
    • /
    • v.17 no.1
    • /
    • pp.76-84
    • /
    • 2003
  • This study was designed to investigate fire characteristics of the plastics insulating materials such as a polystyrene foam, polyurethane foam, and polyethylene foam, which is used an insulating materials i3t workplace. The fire characteristics of plastic insulating materials were carried out from the Cone Calorimeter test according to ISO 5660. The experimental materials used were commercial plastic insulating materials by products and their composition is not disclosed by the manufacturer. As the results of this study; the heat release rate of plastic insulating materials was increased with increasing density and heat flux. The peak heat release rate and the average heat release rate for the polyethylene foam in insulating materials were showed the highest, and the peak heat release rate for the polyethylene foam was the highest. The standard of heat release rate with a kind of products and heat flux of irradiance to prevent fire by plastic insulating materials was suggested.

Combustive Properties of Ethylene-Propylene Die Monomer/Polypropylene/Clay Nanocomposites (에틸렌-프로필렌 디엔 단량체/폴리프로필렌/클레이 나노복합체의 연소성)

  • Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.190-195
    • /
    • 2011
  • Effects of ethylene-propylene diene monomer (EPDM)/polypropylene (PP), zinc oxide, stearic acid, and clay on the combustive properties based on EPDM/PP were investigated. The EPDM/PP/clay nanocomposites was compounded to prepare specimen for combustive analysis by cone calorimeter (ISO 5660-1). It was found that the combustive properties in the nanocomposites decreased due to the fire resistance compared with unfilld EDPM/PP. The nanocomposites showed the lower peak heat release rate (PHRR) than that of virgin EPDM/PP, while stearic acid for softening ruber increased the mean heat release rate (MHRR) by itself, combustible.

A Experimental Study on the Heat Release Rate to activate Fire Detection Sensor (화재감지 센서 작동시간 및 열방출률에 대한 실험연구)

  • Hong, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1358-1361
    • /
    • 2012
  • This paper presents a study on the analysis for activation time and threshold value of heat detection sensor using HRR(Heat Release Rate). And it is represented to quantity of heat to activate heat detection sensor. The experiment is conducted to measure activation time and HRR of fire detection sensor burning alcohol and n-heptane. In order to burn the alcohol and n-heptane using $43.5cm(L){\times}43.5cm(W){\times}5cm(D)$ and $33cm(L){\times}33cm(L){\times}5cm(D)$ steel pan and the quantity of alcohol and n-heptane are 2.5 L and 650 g, respectively. The results show that peak HRR are in case of alcohol 66.13 kW and in case of n-heptane 151.64 kW, respectively. Total heat releases of heat detection sensor are in case of alcohol approximately 20.7 MJ and in case of n-heptane approximately 18 MJ, respectively.

Prediction of Spatial Heat Release Rate of Combustion Chamber by Radicals-PLIF (라디칼 PLIF계측을 이용한 연소실의 공간적 열발생율 예측)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.8 no.4
    • /
    • pp.9-16
    • /
    • 2003
  • The Purpose of this study is to investigate the relationships between the local heat release rate and CH concentration have been investigated by numerical simulations of methane-air premixed flames. And simultaneous CH and OH PLIF(Planar Laser Induced Fluorescence) measurement has been also conducted for lean premixed flame as well as for laminar flames. Numerical simulations are conducted for laminar premixed flames and turbulent ones by using PREMIX in CHEMKIN and two dimensional DNS code with GRI mechanism version 2.11, respectively. In the case of laminar premixed flame, the distance between the peak of heat release rate and that of CH concentration is under $91{\mu}m$ for all equivalence ratio calculated in present work. Even for the premixed flame in high intensity turbulence, the distribution of the heat release rate coincides with that of CH mole fraction. For CH PLIF measurements in the laminar premixed flame burner, CH fluorescence intensity as a function of equivalence ratio shows a similar trend with CH mole fraction computed by GRI mechanism. Simultaneous CH and OH PLIF measurement gave us useful information of instantaneous reaction zone. In addition, CH fluorescence can be measured even for lean conditions where CH mole fraction significantly decreases compared with that of stoichiometric condition. It was found that CH PLIF measurements can be applicable to the estimation of the spatial fluctuations of heat release rate in the engine combustion.

  • PDF

Heat Release Rate Measurements of Residential Combustibles Using Oxygen Consumption Method (산소소모법을 이용한 주택 가연물 발열량 측정)

  • Choi, Byung-Il;Han, Yong-Shik;Kim, Myung-Bae
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.104-107
    • /
    • 2008
  • Heat release rates of main combustibles in residence area were measured by a calorimeter using oxygen consumption method. It was found that the peak heat release rates of the combustibles were 1.0MW for a refrigerator, 0.8MW for a desk, 4.2MW for a wardrobe and 0.4MW for a bed. Especially, the refrigerator and wardrobe were found to be very hazardous because of their fast fire growth rate.

Heat Release Characteristics of Typical Live Fire Load in Large Bookstore (대형서점 적재가연물의 초기 연소발열성상)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book. Based on the results, it has reviewed fire safety when a fire accident occurs on the large bookstore and suggested peak heat release rate per burning surface, fire growth rate, etc of the live fire load required for fire safety design in bookstore.

A Study on Fire Characteristics of Sofa Cover Materials (소파커버의 연소특성에 관한 연구)

  • 이광흠;박영근;윤명오;현성호;김동일
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 2003
  • In this study, we tried to evaluate the ignitibility, flammability, heat release rate, and toxicity of five different types of burning artificial leather sofa covers that are widely used in entertainment service industry buildings. As the results of this study, putting the artificial leathers under fire conditions we found out following results auto-ignition temperature was$ 427~437^{\circ}C$, limiting oxygen index was 19~20%; at heat flux of $25 kW\m^2$, ignition time was 10~16s and peak heat release rate was $147~277 kW\m^2$; and at heat flux of$ 35 kW\m^2$, ignition time was 6~9s and peak heat release rate was $176~296 kW\m^2$. The toxic materials discharged from the burning leathers were 5,550~6,290 ppm of CO, 18,500~23,400 ppm of $CO_2$, 110~140 ppm, of HCl, 13~65 ppm of HCN and 145~220 ppm of NOx.

Combustion Characteristics of Fiber Reinforced Plastic by Cone Calorimeter (콘칼로리미터를 이용한 섬유강화플라스틱(FRP)의 연소특성)

  • 이근원;김관응;이두형
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.67-72
    • /
    • 2004
  • This study describes to assess combustion characteristics of fiber reinforced plastic (FRP) that is used an elements of building or structure in workplace. The combustion characteristics of the fiber reinforced plastic were carried out using by a Cone Calorimeter according to ISO 5660 standard. As the results of this study, the time to ignition and heat release rate of the fiber reinforced plastic was differ with heat flux of irradiance and content of flame retardant agent. The heat release rate of the fiber reinforced plastic was increased with increasing heat flux of irradiance. The flashover propensity of the fiber reinforced plastic using time to ignition and peak heat release rate was examined according to classification method by R.V. Petrella.