Browse > Article
http://dx.doi.org/10.14346/JKOSOS.2017.32.5.20

A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux  

Park, Youngju (Department of Fire & Emergency Management, Kangwon National University)
Kim, Youngtak (Professional Graduate School of Disaster Prevention, Kangwon National University)
Publication Information
Journal of the Korean Society of Safety / v.32, no.5, 2017 , pp. 20-24 More about this Journal
Abstract
In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.
Keywords
peak heat release; total heat released; smoke density; smoke production; cone calorimeter;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 B. W. Shin, Y. H. Song, D. H. Rie and K. S. Chung, "A Study on the Analysis of Smoke Density Characteristics for Wood-Plastic Composites", Journal of Korean Institute of Fire Sci. & Eng. Vol.25, No.3, pp.119-124, 2011.
2 K. W. Lee, K. E. Km and D. Y. Lee, "Combustion Characteristics of Fiber Reinforced Plastic by Cone Calorimeter", Journal of Korean Institute of Fire Sci. & Eng., Vol.18, No.2, pp.68-72, 2004.
3 Y. J. Park, W. J. Kim, H. P. Lee, J. Y. Yu and Y. S.Yang, "A Study on the Characteristics of Smoke Release for Architectural Surface Materials and Architectural Adhesives", J. Korean Soc. Saf., Vol.29, No.1, pp.21-24, 2014.   DOI
4 W. J. Kim, Y. J. Park, H. P. Lee, S. H. Lim and J. I. Kim, "A Study on the Toxicity Analysis of Combustion Gases of Architectural Surface Materials and Architectural Adhesives", J. Korean Soc. Saf., Vol.28, No.4, pp.48-52, 2013.   DOI
5 J. Y. Park, C. S. Baek, H. P. Lee and Y. P .Hong, "A Study on the Heat Release Characteristics of Household Items using LSC(Large Scale Calorimeter)", J. Korean Soc. Saf., Vol.30, No.3, pp.38-44, 2015.   DOI
6 Y. J. Park, "A Study on the Flame Growth Characteristics of Household Items(Refrigerator.Washing machine. Drawer.Sofa)", J. Korean Soc. Saf., Vol.30, No.3, pp.45-51, 2015.   DOI
7 Ministry of Land, Infrastructure and Transport Act 2015-744, "Standard for Fire Resistance Performance and Preventing Fire Diffusion of Building Finishing Materials", 2015.
8 Korea Fire Institute Criteria 205, "Criteria of KFI for Noncombustible and Quasi-noncombustible Materials of Interior Decoration", 2015.
9 Ministry of Public Safety and Security Act 2016-138, "Standards of Flame Retardant Performance", 2016.
10 EN13501-1, "Fire Classification of Construction Products and Building Elements - Part1:Classification using Data From Reaction to Fire Tests", 2010.
11 ISO 5660-1, "Reaction to Fire Tests - Heat Release, Release Rate(cone calorimeter method) and Smoke Production Rate(dynamic measurement)", 2015.
12 Y. T. Km, "A Study on the Combustion of Car Interior Materials", Kangwon National University, 2010.