• Title/Summary/Keyword: partial heating

Search Result 154, Processing Time 0.025 seconds

The influence of atomosphere on high temperature crystal growth

  • Klimm, D.;Schroder, W.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.9 no.4
    • /
    • pp.360-364
    • /
    • 1999
  • The growth of crystals with high melting point$t_{fus}$$\geq$$1600^{\circ}C$ faces the researcher with experimental problems, as the choice of materials that withstand such high t is rather limited. Many metallic construction materials are in this high t range already molten or exhibit at least a drastically reduced mechanical strength. The very few materials with$t_{fus}$$1600^{\circ}C$ as e.g. W, Mo, and partially even Ir are more or less sensitive against oxygen upon heating. Whenever possible, high t crystal growth is performed under inert atmosphere (noble gases). Unfortunately, many oxides are not thermodynamically stable under such conditions, as reduction takes place within such atmosphere. A thoroughly search for suitable growth conditions has to be performed, that are on the one side "oxidative enough" to keep the oxides stable and on the other side "reductive enough" to avoid destruction of constructive parts of the crystal growth assembly. The relevant parameters are t and the oxygen partial pressure${po}_{2}$. The paper discusses quantitatively relevant properties of interesting oxides and construction materials and wasy to forecast theri behavior under growth conditions.

  • PDF

Example study of the insulation characteristic change according to the dryness condition in high voltage motor stator winding (고압전동기 고정자권선의 건조상태에 따른 절연특성 변화사례 고찰)

  • Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2056-2057
    • /
    • 2008
  • This paper is purpose to understand the insulation properties of the high voltage motor stator winding according to the different dryness conditions. we carried out the three times insulation diagnosis test for the same motor stator winding. the first test object is the contaminated winding, second is the washed-out, and natural dried during the 24 hours, and the last is the heating dried in 110$^{\circ}C$ during the 48 hours. the insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, we analyzed and made a comparison of the three cases test result.

  • PDF

Effects of Energy Saving on Partial Heating for Pot Flower Bench Cultivation (분화류 벤치재배시 부분난방에 의한 에너지 절감 효과)

  • 김태영;우영회;조일환;김기덕;이재욱
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2002.04a
    • /
    • pp.44-47
    • /
    • 2002
  • 우리나라 시설재배면적은 2000년말 현재 52,189ha로 이중 가온재배 면적이 13,621ha에 다다르고 있으며 해마다 늘어나는 추세이다. 특히 연간 필요한 난방비는 약4천7백억원으로 상당한 에너지를 소비하고 있는 실정이다. 온실난방 에너지 절감을 위한 국내의 연구는 주로 보온, 난방기의 위치 및 Duct의 토출구 간격 및 직경(Kim 등, 1994), 난방배관 구조개선(Kwon 등, 1992) 지역별 난방부하 결정(Woo 등, 1998) 등을 중심으로 이루어져 왔으며 분화류와 같은 작물을 벤치재배하는데 벤치부분난방시 난방배관재의 종류 및 배관재의 간격등이 연구된바가 없으며 또한 최근 경기불황과 급격한 에너지 가격상승은 더욱 에너지 절감이 중요성을 부각시키고 있다. (중략)

  • PDF

Characteristics of shaft Vibration due to Rubbing in the Steam Turbines (증기 터빈에서의 고체 마찰에 의한 축 진동 특성)

  • 하현천;최성필
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.179-183
    • /
    • 1999
  • Rubbing occurs when a rotating element comes in contact with a stationary element. In the steam turbines, the rotating element is the rotor while the stationary elements are usually the oil deflectors and packing seals. Rubbing phenomenon may be often obseued on a new or rebuilt machine rather than on a machine that has been operating for several months or years. Rubbing in the turbine has been classified into two modes by the operating conditions: 1) start up or shut down, 2) steady state. At start up or shut down operation, rubbing produces synchronous whirl vibration, which are caused by thermal bow of the shaft due to localized heating on the shaft surface. While subsynchronous whirl vibration is caused by partial rubbing during the steady state operation. In this paper, the two case studies of troubleshooting for excessive vibration caused by rubbing in the actual steam turbines are investigated.

  • PDF

A study on Flow Characteristic inside Passenger's Compartment under Recirculation Cool vent mode using CFX (CFX를 이용한 내부순환모드에서의 자동차 내부 유동특성 연구)

  • Kim, Yoon-Kee;Yang, Jang-Sik;Kim, Kyung-Chun;Ji, Ho-Seong
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The flow characteristics under recirculation cool vent mode is numerically studied using commercial fluid dynamic code(CFX). For the reliable analysis, real vehicle and human FE model is employed in grid generation process. The geometrical location and shape of panel vent, and exhaust vent is set as that of real vehicle model. The flowrate of the working fluid is determined as 330CMH which is equivalent to 70 percent of maximum capacity of HVAC system. The high velocity regions are formed around 4 each panel vent. Because of the non-symmetrically located exhaust, non-uniform flow and partial backflow near the door trim is observed. Streaklines start from each panel vent show the flow pattern of the airflow in the passenger's compartment very well.

Effect of a chemical reaction on magnetohydrodynamic (MHD) stagnation point flow of Walters-B nanofluid with newtonian heat and mass conditions

  • Qayyum, Sajid;Hayat, Tasawar;Shehzad, Sabir A.;Alsaedi, Ahmed
    • Nuclear Engineering and Technology
    • /
    • v.49 no.8
    • /
    • pp.1636-1644
    • /
    • 2017
  • The main purpose of this article is to describe the magnetohydrodynamic stagnation point flow of Walter-B nanofluid over a stretching sheet. The phenomena of heat and mass transfer are based on the involvement of thermal radiation and chemical reaction. Characteristics of Newtonian heating are given special attention. The Brownian motion and thermophoresis models are introduced in the temperature and concentration expressions. Appropriate variables are implemented for the transformation of partial differential frameworks into sets of ordinary differential equations. Plots for velocity, temperature, and nanoparticle concentration are displayed and analyzed for governing parameters. The skin friction coefficient and local Nusselt and Sherwood numbers are studied using numerical values. The temperature and heat transfer rate are enhanced within the frame of the thermal conjugate parameter.

Direct acid Leaching of zinc from Marmatite ores 2 Kinetics of Autoclave Leaching of Synthetic ${\beta}$-ZnS (Marmatite 鑛의 直接酸浸出에 關한 硏究 (第2報) ${\beta}$-ZnS Autoclave Leaching의 反應機構에 關한 硏究)

  • Kim Jae Won
    • Journal of the Korean Chemical Society
    • /
    • v.11 no.1
    • /
    • pp.33-37
    • /
    • 1967
  • The influence of impurities contained in Marmatite ores on leaching of zinc was investigated. The zinc sulfide having the same crystal structure of natural Sphalerite was prepared by heating the zinc sulfide chemically precipitated, at $650^{\circ}C$ in nitrogen atmosphere. The activation energy of the sample was 25.8 kcal per mole in the leach test when oxygen partial pressure was 5 atm. and the value was exceedingly high compared to that obtained in Marmatite ores. Synthetic zinc sulfides added with small amount of each impurities were treated in same procedure. As a result, it was found that the leaching velocity was accelerated sharply when about 1 percent of $Cu^{++}$ was blended to the sample. Larger amount of iron has also same effect but the effect was minor compared to the copper. The other impurities indicated no appreciable catalytic action.

  • PDF

An Experimental Study on the Supposed Heating Temperature of Exposed Concrete at High Temperature (고온에 노출된 콘크리트의 수열온도 추정을 위한 실험적 연구)

  • Jang Jea bong;Lee Eui Bae;Cho Bong Suk;Kim Yong Ro;Kwon Young Jin;Kim Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.157-160
    • /
    • 2004
  • If concrete structure is exposed to high temperature such as long-term fire, damages affecting partial or whole structure system may occur. Therefore accurate diagnosis of deterioration is needed based on mechanism of fire deterioration in general concrete structures. Fundamental information and data on the properties of concrete exposed to high temperature are necessary. Especially, the amount of fire damage done to concrete depends on the materials, the standard design compressive strength of concrete, and heated temperature. So, the object of this study is to present data for supposed heated Temperature of deteriorated concrete by fire.

  • PDF

Development of Microwave-Matrix Reformer for Applying SOFC Stack (SOFC 스택 적용 마이크로웨이브-매트릭스 개질기 개발)

  • AN, JUNE;CHUN, YOUNG NAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.534-541
    • /
    • 2021
  • In this study, a novel microwave-matrix reformer was proposed to convert CH4, which is a major component, to a high quality hydrogen energy. And to identify this performance, it was investigated for O2/C ratio, steam feed amount and reformed gas recirculation which are affected for methane conversion and product gas yield. Through the parametric screening studies, optimal operating conditions were that O2/C ratio, steam feed amount and recirculation rate were 1.1, 10 mL/min and 30 L/min. In this conditions, CH4 conversion was 68.1%, H2 selectivity 77.2 and H2/CO ratio 2.62 which are possible applying SOFC stack for RPG (residential power generator).

The Influence of Atmostphere on High Temperature Crystal Growth

  • Klimm, D.;Schroder, W.
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1999.06a
    • /
    • pp.51-67
    • /
    • 1999
  • The growth of crystals with high melting points tfus$\geq$1$600^{\circ}C$ faces the researcher with experimental problems, as the choice of materials that withstand such high t is rather limited. Many metallic construction materials are in this high t range already molten or exhibit at least a drastically reduced mechanical strength. The very few materials with tfus》1$600^{\circ}C$ as e.g. W, Mo, and partially even Ir are more or less sensitive against oxygen upon heating. Whenever possible, high t crystal growth is performed under inert atmosphere (noble gases). Unfortunately, any oxides are not thermodynamically stable under such conditions, as reduction takes place within such atmosphere. A thoroughly search for suitable growth conditions has to be performed, that are on the one side "oxidative enough" to keep the oxides stable and on the other side "reductive enough" to avoid destruction of constructive parts of the crystal growth assembly. The relevant parameters are t and the oxygen partial pressure pO2. The paper discusses quantitatively relevant properties of interesting oxides and construction materials and ways to forecast their behavior under growth conditions.r growth conditions.

  • PDF