• Title/Summary/Keyword: parking space

Search Result 353, Processing Time 0.026 seconds

Characteristics of Planting Design according to Parking Lots Type in Multi-family Housing Complex (공동주택단지의 주차장 유형에 따른 식재특성)

  • Hong, Seong-Rae;Jeong, Dae-Young;Shim, Sang-Ryul
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.1
    • /
    • pp.43-49
    • /
    • 2009
  • The number of registered vehicles increased to one million in 1985 and ten million in 1997, and the parking lots in multi-family housing complex that had been mainly constructed on the ground level began to be constructed in underground levels. Therefore, planting design in such complex were greatly changed. This study classifies the parking lots in multi-family housing complexes located in Cheongju into three categories: above-ground, mixture of above-ground and underground, and underground. The characteristics of planting design in each were then analyzed. The rate of parking per family increased by two or more in the type of mixture when compared to in the type of above-ground. As underground parking lots became dominant, the rate of parking per family increased to one car or more. The green area ratio did not change considerably when above-ground parking was combined with underground parking, but the green area per total floor space was reduced, which indicates the quality of green area became lower. Most of the parking lots in multi-family housing complexes since 2000 have been constructed underground, and the green area became larger. As for the species of trees used in planting design, trees that are vulnerable to damage by blight and harmful insects and may be repugnant have been reduced and replaced by trees whose shapes are beautiful and whose flowers and fruits can be appreciated, such as Chionanthus retusa, Malus floribunda, Styrax japonicus, Prunus mume, Lagerstroemia indica. Pine trees are variously planted with diversified standards, and, in particular, tall pine trees are being utilized as focal points. Herbaceous flowers began to be planted in underground parking lots constructed since 2000, and they are expected to be planted even more due to the appreciation of their flowers and their splendid appearance.

Influence of Interiorlandscape in Commercial Spaces on the Management Benefits (상업공간 실내조경이 경영적 효과에 미치는 영향)

  • 김수연;이종석
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.1-9
    • /
    • 2000
  • The purpose of this study is to examine influence of interior landscape in commercial spaces on the management benefit. In the course of this study, objects of survey were selected from interior landscaping specialist, manager and consumer who had experiences to visit to the hotel, bank, department store and restaurant. The main method of data collection was interview, questions and gathering materials. The cronbach's alphas program was used to measure the reliability of likert scales. The analysis program was applied a statistical methods. The results of this study can be summarized as follows: The factors considered by consumer who visits to the commercial space are design, interior landscape, traffic, parking capacity, cleanness, price, kindness of employee and event. Factors concerned with the product include branch size, traffic, parking capacity, kindness of employee. Factors concerned with facilities include branch size, traffic, parking capacity, kindness of employee. Major factors of those effects to management benefit are accessibility, time of stay, sales, efficiency of space, attractiveness and difference. In conclusion, overlap style gets the highest degree of satisfaction among total factors. Results of the survey show that factors which improve sales are overlap style and planter type. Among four commercial spaces, hotel is most effected by interior landscape. To enhance the sales of hotel, further study of interior landscape about hotel necessary. For bank and restaurant, further study of economic planter type and style is necessary. For department store, optimal use of spaces and case of maintenance are necessary.

  • PDF

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

A Study on the Development of Levying Garage Option on Car Buyers Policy Compliance Model (차고지증명제정책 순응모형 구축에 관한 연구)

  • Kim, Kyung Bum;Hwang, Kyung Soo;Choi, Jai Sung
    • Journal of Korean Society of Transportation
    • /
    • v.30 no.6
    • /
    • pp.13-26
    • /
    • 2012
  • In this study, factors influencing the parking policy compliance (i.e. levying a garage option on car buyers) were identified, and then, were applied to the theory of planned behavior. To find out the influence of factors and their path, the study built a parking policy compliance model using structural equation modeling. The independent variables such as attitude, subjective norm, perceived behavioral control had positive effects on the parameter describing the efforts to secure his garage, but the parameter impact on the dependent variable was not significant. In the end, the independent variables affected the dependent variable was not significant. The perceived behavioral control utilizing regulations had positive effects on the parking policy compliance behavior, but past behavior such as street parking and prowling to find a free parking space had a negative effect on parking policy compliance behavior.

The Analysis of Runoff Characteristics by Alterations of SCS-CN Value using LID Method (LID 기법 적용에 의한 SCS-CN값 변화가 강우유출특성에 미치는 영향 분석)

  • Kwon, Jun-Hee;Park, In-Hyeok;Ha, Sung-Ryoung
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.49-57
    • /
    • 2010
  • The objective of the research is to analyze changing trend of water discharge in precipitation, according to changing land use, through an environment-friendly urban development method called LID. The study chose S1 basin (Separated Sewer districts) in Cheongju region for survey. Among LID methods, relatively more applicable methods of green rooftop space and parking lot with permeable material were selected to construct plausible scenarios. Curve Number (CN) value was calculated due to land use patterns in each scenario, and SWMM model simulation were conducted during 2008 for comparative analysis. For Case 1, only parking lot with permeable material was applied to the scenario. Green rooftop space I and II were applied to Case 2 and 3 respectively. For Case 4 and 5, green rooftop space I and II were applied, in addition to parking lot with permeable material, Calculation of CN value showed that for S1 basin, the value was 88.1 (prior to scenario application), 86.5 (Case 1), 81.9 (Case 2), 68.5 (Case 3), 80.4 (Case 4) and 67.2 (Case 5). Changing pattern of rain water discharge was analyzed for each scenario. For Case 1, the change was not remarkable before and after application of scenario. In Case 2 and 4, the impact of rain water discharge as source of pollutant fell to 20~30%. The rate dropped to 30~50% in Case 3 and 5 respectively. The result demonstrates that the amount of rain water discharge, amount and frequency of sewer overflow, frequency of rain water discharge, and pollution load decreased in accordance with declining CN value in each scenario. In installing green rooftop space, the effect was twice greater when rain water discharge was directly infiltrated into soil.

Study on the Causes of Open Space Loss of Schools in Ulaanbaatar City (울란바타르시 학교 내 녹지 감소원인에 관한 연구)

  • Ochir, Batchimeg;Seo, Ju-Hwan;Choi, Jaehyuck
    • Journal of Korean Society of Rural Planning
    • /
    • v.22 no.4
    • /
    • pp.37-47
    • /
    • 2016
  • The purpose of this study was to analyze the loss of open space of schools in Ulaanbaatar city and found out main causes of the conversion trend of open space to suggest alternatives. 76 designated sites were selected from 118 public schools within 6 districts of Ulaanbaatar city. These 76 schools were eligible for analysis of the open space change between 2005 and 2015 with Google Earth Pro. The results showed that $175,048m^2$ open space was developed and two dominant types of open space conversion were found; 1) constructions of school facilities such as soccer field, extended school buildings, parking lot, sidewalk, and square, and 2) constructions of apartment buildings and service facilities such as community center, pedestrian, sports facilities, and parking lot. Apartment complex development has commonly happened in all districts and caused bigger open space loss than other types of development. Chingeltei district is located in the center of Ulaanbaatar city, and schools in this district lost the biggest open space, $50,036m^2$/35.24% over 10 years. The rate of open space loss seemed to be related to the distance from the urban center and open space loss was an ongoing event in Ulaanbaatar city. This trend would not be improved without a strong regulation, so, in this study, making strict regulations that prevent conversions of open space were suggested to conserve open space in Ulaanbaatar city.

A Study on Track Distribution Function of Urban Rail Systems (도시철도 선로의 배선기능 증진에 관한 연구)

  • Hong, Chul-Kee;Yang, Shin-Chu;Kim, Youn-Tae
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1174-1179
    • /
    • 2004
  • In general, the national rail system put an emphasis on distribution planing of stations for smooth operation of transporting goods, train allocation, parking, and maintenance. Since the national rail system is operated on the ground level, it is feasible to improve various aspects of the system during its operation. On the contrary, urban rail system is operated in the limited space under the ground, and thus, improving various aspects of the system during its operation is infeasible. Specifically, the urban subway system must have a comprehensive track distribution plan because the urban subway system has to operate in a limited environment such as it operates in a much shorter time period, The subway system has to be ready for various operations and events such as trains returning in the opposite direction. parking trains that need repair, parking during night time, storing various maintenance equipments, and connections to other tracks. Furthermore, considering the future extension of tracks, a comprehensive track distribution plan is a must.

  • PDF

The Post-Occupancy Evaluation of Outdoor Environments in Bundang Model Complex: With Super High-rise.High-rise.Low-rise Apartments in Hyundai Apartment Complex (분당시범단지 초고층.고층.저층단지의 옥외환경평가 : 현대아파트 단지를 중심으로)

  • 김유일;함지현;강석희
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.2
    • /
    • pp.130-139
    • /
    • 1999
  • The survey site, the Hyundai Apartment Complex in the Bundang Model Complex, includes three housing layout types; super high-rise, high-rise and low-rise apartment buildings. The site includes artificial ground over underground parking lots. The overall objective of this study is to evaluate social and physical factors of housing environments in each types of layout. The data has been complied from residents of apartment through questionnaire. The questionnaire include elements of neighborhood, outdoor space, parking zones, and the overall complex design in each layout types. The predictors of outdoor space satisfaction in apartment housing complex are found as follows: "abundance of trees in quantity", "the role as front yards", "harmony of buildings with landscape", "the more distance between buildings" and "maintenance quality of site". Layout of super high-rise apartment site is most satisfied. Introduction of car-free deck space is favored by resident because of safty and quiet resting area. However the low quality of green and lack of shades on the artificial land are identified as problems.on the artificial land are identified as problems.

  • PDF

The Characteristics of Mixed-use School and Park with Parking Facility in Urban Residential Area (도시 주거지 학교와 공원의 주차장 입체화 사례의 형태와 이용 특성 분석)

  • Kim, Yoon-Sun;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.153-158
    • /
    • 2011
  • According to the change of life environment and economic growth, the more city has highly developed, the more concentrated urban function. That is, city is required for adding infra structure. But, both of limited land resources and financial problems made it impossible to add infra structure. So, the necessity of multi-dimensional planning of urban infra structure was recognized. Especially, In Urban residential area, in order to secure parking area, It is on the increase that mixed-use of the playground of school in the high density area and the empty space of park. School and park is closely connected with town community, playing a central role on town life. For this reason, they are highly demanded for providing space in the urban residential area and also expected to be effective. However, people using park and school are almost young students and the elderly, it needs to consider not only the parking convenience also the safety of users in design process. In this study, we analysed the physical characteristics and the utilization of mixed-use of school and park. and then evaluated the case in the point of convenience and safety. For this, first we selected the case among the sites constructed in seoul, and divided 2type of 'slope type' and 'flatland type'. The meaning of this study is to suggest elementary standards for design in the point of multi-dimensional land use planning.

  • PDF