• Title/Summary/Keyword: parallel cut

Search Result 127, Processing Time 0.023 seconds

Classification of Consonants by SOM and LVQ (SOM과 LVQ에 의한 자음의 분류)

  • Lee, Chai-Bong;Lee, Chang-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.1
    • /
    • pp.34-42
    • /
    • 2011
  • In an effort to the practical realization of phonetic typewriter, we concentrate on the classification of consonants in this paper. Since many of consonants do not show periodic behavior in time domain and thus the validity for Fourier analysis of them are not convincing, vector quantization (VQ) via LBG clustering is first performed to check if the feature vectors of MFCC and LPCC are ever meaningful for consonants. Experimental results of VQ showed that it's not easy to draw a clear-cut conclusion as to the validity of Fourier analysis for consonants. For classification purpose, two kinds of neural networks are employed in our study: self organizing map (SOM) and learning vector quantization (LVQ). Results from SOM revealed that some pairs of phonemes are not resolved. Though LVQ is free from this difficulty inherently, the classification accuracy was found to be low. This suggests that, as long as consonant classification by LVQ is concerned, other types of feature vectors than MFCC should be deployed in parallel. However, the combination of MFCC/LVQ was not found to be inferior to the classification of phonemes by language-moded based approach. In all of our work, LPCC worked worse than MFCC.

Studies on Wood Quality of Pinus koraiensis Sieb. et Zucc. (II) -On the Gross Structural Features of Stem - (잣나무의 재질(材質)에 관(關)한 연구(硏究) (제(第)2보(報)) -수간(樹幹)의 구조적(構造的) 형질(形質)-)

  • Lee, Won Yong
    • Journal of Korean Society of Forest Science
    • /
    • v.17 no.1
    • /
    • pp.17-22
    • /
    • 1973
  • A study on the wood quality from planted Pinus koraiensis Sieb. et Zucc. has been undertaken by the University Forest in order to gain results of the gross structural features of stem. For this study some groups of trees were felled and several characteristics such as the degree of stem, slenderness, eccentric growth, heartwood diameter, height of butt sweep and butt-swell were analyzed. The results of the study are as follows. 1) The relation between diameter of log and its height in sample trees are nearly parallel to each other. But their degrees of slenderness in logs cut from intermediate and codominant trees are some what gentle as compared with that of logs from dominant tree. 2) The eccentric growth at transverse section of sample trees is generally decreased with the increase of tree height on all sample trees. 3) On the eccentric growth at transverse section of tree, a rather distinct tendency was noticed that all of sample trees showed the direction of eccentric growth in $R_2$ side. 4) Heartwood diameter appeares to become larger as tree growth decrease under same diameter of logs and log diameter in which heartwood appeares is larger in rapid growth rate trees. 5) The maximum height of butt-sweep generally shows that the larger the breast height diameter of tree is, the smaller its height becomes. On the contrary it was noticed that the larger the breast height diameter of trees, the higher the maximum height of butt-swell became. The direction of butt-sweep and butt-swell were shown in $R_1$ side in all sample trees.

  • PDF

Numerical Study on the Thermal Control Device for Satellite Components Using the Phase Change Material Combined with Heat Pipe in Parallel (상변화물질과 열관을 병렬 조합한 위성부품 열제어장치의 수치해석적 연구)

  • Shin, Yoon Sub;Kim, Tae Su;Kim, Taig Young;Seo, Young Bae;Seo, Jung-gi;Hyun, Bum-Seok;Cheon, Hyeong Yul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.4
    • /
    • pp.373-379
    • /
    • 2016
  • The thermal control device for the periodic working component combined solid-liquid phase change material (PCM) with heat pipes is designed and numerically studied. Due to high latent heat and retaining constant temperature during melting process the component peak temperature, not withstanding small radiator size, is reduced. The warm-up heater power consumption to keep the minimum allowed temperature is also cut down since the accumulated thermal energy is released through the solidification. The thermal buffer mass (TBM) made of Al can give the similar effect but the mass and power consumption of warm-up heater should increase compared to PCM. The amount of PCM can be optimized depending on the component heat dissipation and on/off duty time.

Microscopic Studies of the Magnetic and Thermal Properties in Ba-ferrite Single Crystal (Ba-Ferrite 단결정의 자기적 및 열적 현상에 관한 미시적 연구)

  • Sur, J.C.;Choi, J.W.
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.4
    • /
    • pp.152-155
    • /
    • 2009
  • Ba-Ferrite single crystals were prepared and the magnetic and thermal properties were characterized by Mossbauer spectroscopy. The single crystal layer was cut in the c-axis and radiated to the surface by ${\gamma}$-rays for Mossbauer spectroscopy. We found out that the spin states in Fe ions were parallel to the ${\gamma}$-rays direction and the whole crystal bulk formed only one crystal with the same spin direction. $M\"{o}ssbauer$ spectra in single crystal have only 4 sets of 4 absorption lines in each Fe site when the ${\gamma}$-rays have the same radiation direction with the c-axis in the crystal, and there was no 2b-site spectrum. The zero absorption of 2b-site means that there was a fast diffusion motion in a double-well atomic potential at room temperature, in which bipyramidal Fe ions have the two minima at each side mirror plane.

Distribution of the neuropeptide Y immunoreactive neurons in the olfactory bulb of striped field mouse(Apodemus agrarius) (야생등줄쥐(Apodemus agrarius) 후각망울의 neuropeptide Y 면역반응세포의 분포)

  • Jeong, Young-gil;Kim, Kil-soo;Jung, Ju-young;Lee, Nam-seob;Lee, Kyeng-youl;Kim, Moo-kang
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.407-416
    • /
    • 1999
  • This study was carried out to investigate the NPY-immunohistochemical characteristics of the olfactory bulb in the striped field mouse(Apodemus agrarius). The animals were anesthesized with thiopental sodium and perfused with 4% paraformaldehyde through left ventricle and aorta. Brains were removed and tranfered 10%, 20% and 30% sucrose. Sections were then cut on a cryostat into $40{\mu}m$-thick. The tissue immunostained with avidin-biotinylated complex method. The main olfactory bulb consisted of seven circumferential laminae : an olfactory nerve fiber layer, a glomerular layer with glomeruli surrounding by periglomerular cells, an external plexiform layer having granule and tufted cells, a mitral cell layer, a narrow internal plexiform layer, a granule cell layer forming several cell rows and a layer of white matter. The accessory olfactory bulb had four layers : an olfactory or vomeronasal nerve fiber layer, a glomerular layer consisting of small glomeruli, a mixed layer not distinguishing the external plexiform/mitral cell/granule cell layers and a granule cell layer. Most of NPY-immunoreactive(NPY-IR) neurons in main olfactory bulb were localized in the deeper portion of granule cell layer, white matter and anterior olfactory nucleus. In addition, some NPY-IR neurons were identified in the external plexiform layer. The shape of NPY-IR neurons of all olfactory bulb were predominant round or oval, sometime multipolar in shape. And most NPY-IR processes were parallel to long axis of white matter. In accessory olfactory bulb, NPY-IR neurons were not found in all region.

  • PDF

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.802-807
    • /
    • 2008
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows; 1) On the whole, typical rates of water-use was founded out 15 L/stu. d in pirmary school, 10 L/stu. d in middle school and 30 L/stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking peak load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.510-515
    • /
    • 2007
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows ; 1) On the whole, typical rates of water-use was founded out 15 L / stu. d in pirmary school, 10 L / stu. d in middle school and 30L / stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking pick load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

  • PDF

Complications of Scarf Osteotomy for Hallux Valgus (무지 외반증에서 시행한 Scarf 절골술의 합병증)

  • Nam, Il-Hyun;Ahn, Gil-Yeong;Moon, Gi-Hyuk;Lee, Yeong-Hyeon;Choi, Seong-Pil;Lee, Tae-Hun;Lee, Young-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.4
    • /
    • pp.178-182
    • /
    • 2014
  • Purpose: The purpose of this study was to evaluate the frequency of troughing and stress fracture, which are the major complications of scarf osteotomy, and to suggest methods to prevent these complications. Materials and Methods: We reviewed 243 cases of 137 patients treated with the scarf osteotomy for hallux valgus from January 2005 to December 2012. The mean follow-up period was 2.8 years. During the scarf osteotomy, a long oblique longitudinal osteotomy was performed in order to decrease the possibility of troughing and stress fracture. Radiographs of lateral view of the foot were obtained and the thicknesses of the first metatarsal base at the sagittal plane were measured and compared. Results: There was no troughing during fragment translation and screw fixation intraoperatively. Radiographs of lateral view of the foot taken preoperatively and at the last follow-up showed that the mean thickness of the first metatarsal was 22.4 mm preoperatively and 21.6 mm at the last follow-up, with a mean difference of 0.8 mm. And no stress fracture was observed. Conclusion: To prevent troughing and stress fracture, a long oblique longitudinal cut, parallel to the first metatarsal plantar surface, was performed, making both ends of the proximal segment truncated cone-shape, and securing the strong bony strut of the proximal segment. No troughing or stress fracture was experienced with scarf osteotomy.

Geomorphic development and distributional system of marine terrace in the eastern part of Seopo-myeon, Sacheon-si, Gyeongnam Province (경남 사천시 서포면 동쪽 해안단구 지형 발달과 분포 체계)

  • Yoon, Soon-Ock;Kang, Bong;Park, Chung-Sun;Hwang, Sangill
    • Journal of the Korean association of regional geographers
    • /
    • v.22 no.4
    • /
    • pp.875-886
    • /
    • 2016
  • The eastern coast of Seopo-myeon, Sancheon-si in the South Coast is a bay almost completely separated from open sea by Changseon and Namhae Islands. Marine terraces in this area can be classified into geomorphic surfaces with elevations of 10~12m, 15~18m, 20~24m, 25~28m, 30~33m, 35~38m, 40~45m, 45~50m and 54m. This marine terrace system is similar to the Boryeong area in the West Coast. The geomorphic surfaces distribute along ridges and show relatively small areas. The young and old surfaces show a mixed distributional pattern. This distributional pattern contrasts to the East Coast where the oldest surface farthest from the coastline is parallel to the coast and age of the surfaces increases with a distance from the coast. These seem to result in high energy waves by typhoon that developed wave-cut platform on hill areas with relatively complex relief in a short time.

  • PDF

A Study on the Improvement of Preventive Measures for Improving the Safety of Chemical Reactor (화학반응기의 안전성 향상을 위한 예방조치 개선에 관한 연구)

  • Byun, Yoon Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.32-38
    • /
    • 2020
  • Based on the cases of fire and explosion accident in the chemical reactor, thr problems of preventive measures installed in the chemical reactor were analyzed. The chemical reactors produce a variety of chemicals and install rupture disk to relieve the pressure that rises sharply in the event of a runaway reaction. In order to maintain the function of the rupture disk, the emissions was allowed to be discharged into the atmosphere, resulting in fire and explosion accidents. As a way to improve this, safety instrumented system based on the safety integrity level(SIL3) was applied as a preventive measures for chemical reactor. Two emergency shur-off valves are installed in series on pipe dropping raw materials for chemical reactor so that the supply of raw materials can be cut off even if only one of the two emergency shut-off valves is operated during the runaway reaction. The automatic on/off valve is installed in parallel in the supply pipe of the reaction inhibitor so that the reaction inhibitor can be injected even if only one valve is opened at the time of the runaway reaction.