• Title/Summary/Keyword: outside inflow

Search Result 74, Processing Time 0.026 seconds

The Convergence Study of the Cinematic Gaze Represented in Seojong MA-Residence (서종 MA주택에 구현된 영화적 시선에 대한 융합적 연구)

  • Moon, Guen-Jong
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.293-300
    • /
    • 2017
  • The purpose of this study is to analyze the various cinematic gaze and its realization through Seojong MA-Residence in Yangpyeong-gun, completed in 2016. This paper will focus on what kinds of cinematic concepts and design ideas were selected and considered in the stage of concept design, then how the site plan, floor plan, elevation and section design were developed in the stage of schematic design, and finally how much of the design intentions were successfully realized to the residential building. Architectural sketches, physical models and drawings at the concept & schematic design stage were reviewed. After the construction, some important issues were successfully realized such as interesting cinematic views to outside, visual openness and inflow of sunlight.

Characteristics in Densities and Shapes of Various Particles Produced by Friction between Tire Tread and Road Surface

  • Jung, Uiyeong;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • v.57 no.3
    • /
    • pp.92-99
    • /
    • 2022
  • A large amount of particles on the roads is produced by friction between the vehicles and the road surface and by inflow from outside. The type of these particles affects the abrasion behavior of tire tread. In this study, road dust collected at a bus stop was separated by size, and the particles with sizes of 106-212 mm were analyzed. The particles were separated by density using NaI and NaBr aqueous solutions with densities in the range of 1.10-1.80 g/cm3 with the 0.10 g/cm3 interval. In the road dust sample, the following particle types were found: tire-road wear particles (TRWPs), asphalt pavement wear particles (APWPs), plant-related particles (PRPs), road paint wear particles (RPWPs), and plastic particles (PPs). The densities of TRWPs, APWPs, PRPs, and RPWPs were 1.20-1.80, >1.60, >1.10, and >1.40 g/cm3, respectively, while PPs were found in all density ranges. Additionally, many small mineral particles were observed on the particles. Order of the relative content of the particles was PRP > TRWP > APWP ~ RPWP > PP. APWPs that were stuck to TRWP could be removed by chloroform treatment. The shapes of the particles were characterized using their magnified images.

Thermal Environment Analysis for Preserving Ancient Mural Painting in Songsan-ri Tomb No. 6, Gongju, Korea (공주 송산리 6호 벽화고분 보존을 위한 온열환경 분석 연구)

  • Kim, Dae Woon;Jeong, Sun Hye;Lee, Min Young;Chung, Yong Jae
    • Journal of Conservation Science
    • /
    • v.32 no.4
    • /
    • pp.521-534
    • /
    • 2016
  • Ancient tombs are typically comprised of confined rooms, which have different spatial characteristics than the external environment because they are covered by heavy layers of soil. In this study, we examined the thermal energy flow from the outside to inside of Songsan-ri tomb No. 6. External heat flows slowly to the inside because of heavy soil layer, and the presence of several rooms and entrances. For this reason, it takes about two months for the air temperature to travel from the outside to the inside of the tomb. Interestingly, the gradational inflow of thermal energy from outside the tomb leads to delicate horizontal and vertical variations in the wall temperature. These micro-environmental differences occur in the inner tomb every year, so we can expect them to cause condensation with regularity. In addition, we show that the previously installed forced circulation air conditioning system risks fatal damage to the mural wall painting. The results of this research suggest an optimal air conditioning system and optimized space planning to conserve Songsan-ri tomb No. 6 and its mural painting.

Improvement of sound insulation performance of windows according to the specifications of the external electric blinds (외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과)

  • Min-Woo, Kang;Hee-Dong, Lee;Yang-Ki, Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.621-628
    • /
    • 2022
  • The most realistic way to reduce noise outside the building, such as road traffic noise and aircraft noise, is to strengthen the sound insulation performance at the sound collecting points such as balconies, windows, and exterior walls of each building. However, in light of the reality that shading devices outside buildings are not yet widely used, there are not many studies on sound insulation performance improvement using external windows and window devices such as louvers and blinds. In particular, external blinds can not only block the inflow of strong sunlight in the morning and evening from the outside of the building, but also target the sound insulation effect that blocks the peak noise that occurs during commuting hours. In this study, a study was conducted to improve sound insulation performance against external noise by using an external electric blind (EEB), which is one of the most efficient window and door external shading devices. Various sound insulation performance tests were conducted while changing the configuration of external electric blinds developed for light blocking purposes. Through this, it was verified that an additional sound insulation performance of 6 dB can be obtained by installing an external electric blind compared to the reduction performance of general windows.

Spatiotemporal Variations of Water Quality in Yongil Bay (영일만 수질의 시공간적 변동)

  • Kang Yang Soon;Kim Kui Young;Shim Jeong Min;Sung Ki Tack;Park Jin Il;Kong Jai Yul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.4
    • /
    • pp.431-437
    • /
    • 2002
  • In order to understand the spatiotemporal variation of water quality, an investigation on variation characteristics of water quality was conducted at 13 stations in Yongil bay from 1990 to 1998. The salinity in summer was relatively lower than that in other seasons and it have increased from inner bay to outside of the bay gradually. However, nitrate concentration in summer was relatively higher than that in other seasons, and it was the highest, up to $65.40\%$, among dissolved inorganic nitrogens, Nitrate concentration indicates the possibility of affecting by freshwater discharges to Yongil bay. Correlation analysis showed that salinity had a significantly good correlation with nitrate. This result suggested that inflow of river had an influence on increase of nitrate. The result of Principal Component Analysis (PCA) indicated that nitrate was major factor to influence the water quality in Yongil Bay.

Analysis of Flood Characteristics at Confluence by Lateral Inflow (횡유입에 의한 합류부 홍수특성 분석)

  • Choi, Hung-Sik;Cho, Min-Suk;Park, Young-Seop
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.1 s.20
    • /
    • pp.59-68
    • /
    • 2006
  • Flow separation of recirculation zone by increasing of flow and change of its direction at confluence results in backwater due to conveyance reduction. The hydraulic characteristics of flow separation are analysed by experimental results of flow ratios of tributary and main streams and approaching angles. The boundary of flow separation by dimensionless length and width is defined by the streamline of zero and this definition agrees well to the existing investigation. Because flow separation doesn't appear in small flow ratio and approaching angle of $30^{\circ}$, the equation of flow separation with flow ratio and approaching angle is provided. In flow separation consideration and comparing with previous results, the existing equations of dimensionless length and width ratios by function of approaching angle, flow ratio, and downstream Froude number are modified and also contraction coefficient and shape factor are analysed. Dimensionless length and width ratios are proportional to the flow ratio and approaching angle. In analysis of water surface profiles, the backwater effects are proportional to the flow ratio and approaching angle and the magnitude at outside wall is greater than that of inside wall of main stream. The length, $X_l$ from the beginning of confluence to downstream of uniform flow, where the depth is equal to uniform depth, is characterized by width of stream, flow ratio, approaching angle, and contraction coefficient. The ratios between maximum water depth by backwater and minimum depth at separation are analysed.

A Study on the Characteristics of Small-scale Sewage Treatment Plants in Mountain Area and Operation Plan for Winter Season (산악지역 소규모하수처리시설의 특성 및 동절기 운영방안에 관한 연구)

  • Chae, Heejun;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.2
    • /
    • pp.183-188
    • /
    • 2021
  • In the case of small-scale sewage treatment plants, it is reported that the amount of inflow fluctuates and it is difficult to operate the sewage treatment due to the inflow of unknown water due to the aging of sewage pipes. In particular, there are many overall operational problems due to the decrease in water temperature in winter. In this study, the operation status of small-scale sewage treatment facilities located in mountainous areas and water quality changes according to temperature were analyzed. It was found that the concentration of BOD, COD, and SS in effluent water was greatly changed depending on the temperature, and it was found that COD was particularly affected. Accordingly, the water level of the bioreactor was raised by 0.4m in order to temporarily apply measures to lower the water temperature in winter. As a result of comparing and analyzing the results when the bioreactor was covered and operated, a significant improvement effect occurred. In addition, a plan to improve the treatment efficiency of the bioreactor in winter is to extend the residence time of the bioreactor, a plan to expand the bioreactor specification, a new flow control tank and transport it to the outside, and an oxygen-free air diffuser to be used as an aerobic tank in case of an emergency in winter. The improvement plan was suggested. The results of this study are expected to be used as basic data for the operation plan of small-scale sewage treatment facilities in winter.

Study on the Change of Wind Field and Temperature According to Location of High-rise Building Using Micrometeorology Numerical Model (미기상 수치 모델을 이용한 고층아파트 입지에 따른 바람장 및 기온 변화 연구)

  • Seo, Houng-Seok;Kim, Yoo-Gon;Young, Go-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.340-352
    • /
    • 2011
  • This study was carried out to analyze the change of wind filed and heat island according to the location of the high rise building using micrometeorology numerical model Envi-met3.0. In this study, the real urban planning of Jeonju city was used as input for the location and height of buildings. Modeling was performed for two conditions as input data. Case 1 is that wind direction is SSE and case 2 is W. To analyse the change of wind filed, wind speed results were used. To analyze the change of heat island, temperature results were used. Below the building height, wind speed increased 0.2~2.5 m/s at the inflow area and decreased 0.5~2.0 m/s at the area between the buildings. Above the building height, wind speed decreased 0.1~0.8 m/s near the building complex. On the other hand, wind speed increased 0.2~0.4 m/s in the outside area of the building complex. In the case of temperature, below the building height, temperatures increased $0.01{\sim}0.1^{\circ}C$ in the building complex and leeward area. On the other hand, temperature decreased $0.01{\sim}0.005^{\circ}C$ in the outside area of the building complex. Above the buildings height, temperatures decreased $0.05{\sim}0.2^{\circ}C$ in most of the area.

Interpretation on Internal Microclimatic Characteristics and Thermal Environment Stability of the Royal Tombs at Songsanri in Gongju, Korea (공주 송산리 고분군 내부의 미기후 특성 및 온열환경 안정성 해석)

  • Kim, Sung Han;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.35 no.2
    • /
    • pp.99-115
    • /
    • 2019
  • The Royal Tombs at Songsanri is one of the most important historic site for ancient historical study in Korean Peninsula. Since the excavation of the tombs, continuous exposure to the outside environment and the negative effects of the artificial air conditioning system have caused significant threats to the thermal environment stability of the tombs. Unlike the outside temperature that shows significant differences according to seasonal changes, the burial chamber of the tombs had a relatively stable temperature range of 11.4 to $22.2^{\circ}C$ throughout the year, and the standard deviation of temperature was within 3.5. It was revealed that major factors affecting the microclimate of the tombs were inflow of outdoor air, wind direction and speed, and all of them had closely related to airtightness of the tombs. The solar radiation was in inverse proportion to the thickness of burial mounds, and thus Royal Tomb of King Muryeong, which has the thickest burial mound, was least affected by solar radiation. Especially, microclimate of the tombs caused to the highest influence with artificial environmental changes due to access by people, which varied in proportion to the number of accessed people and time of stay. Currently, the inside of the tombs are sealed and always in saturated condition, it is very vulnerable to dew condensation. As a result of analyzing the possibility of condensation in each tomb, all the tomb No. 5, tomb No. 6 and Royal Tomb of King Muryeong had condensation most of the time throughout the year. It is required to make a proper conservation environment for the Royal Tombs at Songsanri.

A Study on Savings Analysis of Light Dimming Control System Using the Daylight based on Photovoltaic Power Generation (태양광발전 기반의 주광을 활용한 조명제어 시스템의 에너지 절감량 분석 연구)

  • Ham, Won-Tae;Jang, Cheol-Yong;Jeong, Hak-Guen
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.11-21
    • /
    • 2012
  • In the normal office building, the energy consumption to maintain the reasonable intensity of illumination for the work by using the artificial illumination occupies 30% or greater of the whole building electric energy consumption. If the dependability of the artificial illumination is dropt by positively using the natural lighting from the outside, the large amount of electrical energy can be saved, in addition the more nice visual environment for work can be created. Daylight is lighting source that most closely match visual response of the human, because sunlight and skylight achieve the harmony. For this reason, the daylight of small amount than amount of the artificial lighting source also can give the same effect in work activities of human. In addition, if there is daylight at the window of the building, the energy can be saved by controlling the artificial lighting. In this paper, in the building using the photovoltaic power generation analyze the correlation between the amount of energy generated by photovoltaic and indoor illumination and this was proved through the simulation with Relux 2010. In addition, the amount of daylight inflow in the room and distribution was drawn by the equation and the ratio for the sectional dimming control of each lighting equipment was predicted and the energy saving amount according to this was calculated. As a result, the indoor illumination was satisfied with recommended illumination value of the office and consumption power could be reduced approximately with 20~70%.