• Title/Summary/Keyword: output-only information

Search Result 739, Processing Time 0.026 seconds

Frequency Synchronization Technique for the Equalization Digital On-Channel Repeater (등화형 디지털동일채널중계기의 송수신 신호 간 주파수 동기화 기술)

  • Lee Yong-Tae;Eum Ho-Min;Park Sung-Ik;Seo Jae-Hyun;Kim Heung-Mook;Kim Seung-Won;Seo Jong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7A
    • /
    • pp.725-733
    • /
    • 2006
  • In this paper, we propose an algorithm which makes the frequency of output signal synchronize with frequency of input signal in Equalization Digital On-channel Repeater (EDOCR) system which was proposed to overcome the disadvantage of conventional Digital On-Channel Repeater (DOCR). Also, we verify the algorithm by using the mathematical equivalent model and analysis the performance by implying the algorithm to EDOCR. The main idea is to use the frequency offset information, which comes from carrier recovery in the receiving part of EDOCR, when the demodulated symbol is re-modulated in transmitting part. Based on the proposed algorithm, EDOCR not only makes the output signal synchronized with input signal in frequency but also emit the output signal which satisfies the ATSC transmission standard without additional equipments such as Global Positioning System (GSP).

Operation of NMOSFET-only Scan Driver IC for AC PDP (NMOSFET으로 구성된 AC PDP 스캔 구동 집적회로의 동작)

  • 김석일;정주영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.7
    • /
    • pp.474-480
    • /
    • 2003
  • We designed and tested a new scan driver output stage. Compared to conventional CMOS structured scan driver IC′s, the new NMOSFET-only scan driver circuit can reduce the chip area and therefore, the chip cost considerably. We confirmed the circuit operation with open drain power NMOSFET IC′s by driving 2"PDP test panel. We defined critical device parameters and their optimization methods lot the best circuit performance.

High-linearity voltage-controlled current source circuits with wide range current output (넓은 범위의 전류 출력을 갖는 고선형 전압-제어 전류원 회로)

  • 차형우
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.7
    • /
    • pp.89-96
    • /
    • 2004
  • High-linearity voltage-controlled current sources (VCCSs) circuits for wide voltage-controlled oscillator and automatic gain control are proposed. The VCCS consists of emitter follower for voltage input, two common-base amplifier which their emitter connected for current output, and current mirror which connected the two amplifier for large output current. The VCCS used only five transistors and a resistor without an extra bias circuit. Simulation results show that the VCCS has current output range from 0㎃ to 300㎃ over the control voltage range from 1V to 4.8V at supply voltage 5V. The linearity error of output current has less than 1.4% over the current range from 0A to 300㎃.

A Maximum Power Point Tracking Control for Photovoltaic Array without Voltage Sensor

  • Senjyu Tomonobu;Shirasawa Tomiyuki;Uezato Katsumi
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.617-621
    • /
    • 2001
  • This paper presents a maximum power point tracking algorithm for Photovoltaic array using only instantaneous output current information. The conventional Hill climbing method of peak power tracking has a disadvantage of oscillations about the maximum power point. To overcome this problem, we have developed a algorithm, that will estimate the duty ratio corresponding to maximum power operation of solar cell. The estimation of the optimal duty ratio involves, finding the duty ratio at which integral value of output current is maximum. For the estimation, we have used the well know Lagrange's interpolation method. This method can track maximum power point quickly even for changing solar insolations and avoids oscillations after reaching the maximum power point.

  • PDF

Fuzzy control system design by data clustering in the input-output subspaces (입출력 부공간에서의 데이터 클러스터링에 의한 퍼지제어 시스템 설계)

  • 김민수;공성곤
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.12
    • /
    • pp.30-40
    • /
    • 1997
  • This paper presents a design method of fuzzy control systems by clustering the data in the subspace of the input-output produyct space. In the case of servo control, most input-outputdata are concentrated in thye steady-state region, and the the clustering will result in only steady-state fuzzy rules. To overcome this problem, we divide the input-output product space into some subspaces according to the state of input variables. The fuzzy control system designed by the subspace clustering showed good transient response and smaller steady-state error, which is comparable with the reference fuzzy system.

  • PDF

PCS Power Characteristics of PV System by Fuzzy Controller (퍼지제어에 의한 PV시스템의 PCS 출력특성)

  • MOON E. A.;LIM H. W.;BAEK H. L.;CHO G. B.;OH G. K.;LIM Y. S.;KIM P. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.147-150
    • /
    • 2004
  • Maximum power point tracking for PV systems traditionally uses either perturbation and observation method or incremental conductance method. Both methods require modulation of the output voltage and this leads to significant power loss. In this paper, a method, which senses output circuit voltage and short circuit current and use the above two parameters for optimum control with a fuzzy controller, is introduced. The short circuit current of PV cell represents illumination, and the output circuit voltage carry on information about the temperature. PCS(power conditioning system) is controlled not only feed to inverter for stability voltage variation despite of variety external environment, but also operate in order to feeding voltage and current at maximum power point by boost type chopper.

  • PDF

A Maximum Power Point Tracking Control for Photovoltaic Array without Voltage Sensor

  • Senjyu, Tomonobu;Shirasawa, Tomiyuki;Uezato, Katsumi
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.155-161
    • /
    • 2002
  • This paper presents a maximum power point tracking algorithm for Photovoltaic array using only instantaneous output current information. The conventional Hill climbing method of peak power tracking has a disadvantage of oscillations about the maximum power point. To overcome this problem, we have developed an algorithm that will estimate the duty ratio corresponding to maximum power operation of solar cell. The estimation of the optimal duty ratio involves, finding the duty ratio at which integral value of output current is maximum. For the estimation, we have used the well know Lagrange's interpolation method. This method can track maximum power point quickly even for changing solar isolation and avoids oscillations after reaching the maximum power point.

Output Feedback Dynamic Surface Control of Flexible-Joint Robots

  • Yoo, Sung-Jin;Park, Jin-Bae;Choi, Yoon-Ho
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.2
    • /
    • pp.223-233
    • /
    • 2008
  • A new output feedback controller design approach for flexible-joint (FJ) robots via the observer dynamic surface design technique is presented. The proposed approach only requires the feedback of position states. We first design an observer to estimate the link and actuator velocity information. Then, the link position tracking controller using the observer dynamic surface design procedure is developed. Therefore, the proposed controller can be simpler than the observer backstepping controller. From the Lyapunov stability analysis, it is shown that all signals in a closed-loop system are uniformly ultimately bounded. Finally, the simulation results of a three-link FJ robot are presented to validate the good position tracking performance of the proposed control system.

Logic gate implementation of constant amplitude coded CS/CDMA transmitter (정포락선 부호화된 CS-CDMA 송신기의 논리 게이트를 이용한 구현)

  • 김성필;류형직;김명진;오종갑
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.281-284
    • /
    • 2003
  • Multi-code CDMA is an appropriate scheme for transmitting high rate data. However, dynamic range of the signal is large, and power amplifier with good linearity is required. Code select CDMA (CS/CDMA) is a variation of multi-code CDMA scheme that ensures constant amplitude transmission. In CS/CDMA input data selects multiple orthogonal codes, and sum of these selected codes are MPSK modulated to convert multi-level symbol into different carrier phases. CS/CDMA system employs level clipping to limit the number of levels at the output symbol to avoid hish density of signal constellation. In our previous work we showed that by encoding input data of CS/CDMA amplitude of the output symbol can be made constant. With this coding scheme, level clipping is not necessary and the output signal can be BPSK modulated for transmission. In this paper we show that the constant amplitude coded(CA-) CS/CDMA transmitter can be implemented using only logic gates, and the hardware complexity is very low. In the proposed transmitter architecture there is no apparent redundant encoder block which plays a major role in the constant amplitude coded CS/CDMA.

  • PDF

An Application of Linear Singular System Theory To Electric Circuits (선형 Singular 시스템 이론의 전기 회로에의 적용)

  • Hoon Kang
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.12
    • /
    • pp.1625-1632
    • /
    • 1988
  • This paper aims not only to introduce the concept of linear singular systems, geometric structure, and feedback but also to provide applications of the multivariable linear singular system theories to electric circuits which may appear in some electronic equipments. The impulsive or discontinuous behavior which is not desirable can be removed by the set of admissible initial conditions. The output-nulling supremal (A,E,B) invariant subspace and the singular system structure algorithm are applied to this double-input double-output electric circuit. The Weierstrass form of the pencil (s E-A) is related to the output-nulling supremal (A,E,B) invariant subspace from which the time domain solutions of the finite and the infinite subsystems are found. The generalized Lyapunov equation for this application with feedback is studied and finally, the use of orthogonal functions in singular systems is discussed.

  • PDF