• 제목/요약/키워드: operational calibration

검색결과 52건 처리시간 0.026초

레이더에 의한 개선된 강우강도와 면적 강우량의 실시간 추정 (Improvement of Radar Rainfall Intensity and Real-time Estimation of Areal Rainfall)

  • 정성화;김경익;김광섭
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2006년도 학술발표회 논문집
    • /
    • pp.643-646
    • /
    • 2006
  • An operational calibration is applied to improve radar rainfall intensity using rainfall obtained from rain gauge. The method is applied under the assumption of the temporal continuity of rainfall, the rainfall intensity from rain gauge is linearly related to that from radar. The method is applied to the cases of typhoon and rain band using the reflectivity of CAPPI at 1.5km obtained from Jindo radar. The CAPPI is obtained by bilinear interpolation. For the two cases, the rainfall intensities obtained by operational calibration are very consistent with the ones by the rain gauges. The present study shows that the correlation between the rainfall intensity by operational calibration and rain gauges is better than the one between the rainfall intensity by M-P relationship and rain gauges. The correlation coefficients between the total rainfall intensity obtained by operational calibration and rain gauges in typhoon and rain band cases are 0.99 and 0.97, respectively. Areal rainfalls are estimated using the field of calibration factor interpolated by Barnes objective analysis. The method applied here shows an improvement in the areal rainfall estimation. For the cases of typhoon and rain band, the correlation between the areal rainfall by operational calibration and rain gauges is better than the one between the area rainfall by M-P relationship and rain gauges. The correlation coefficients between the areal rainfall obtained by operational calibration and rain gauges in typhoon and rain band cases are 0.97 and 0.84, respectively. The present study suggests that the operational calibration is very useful for the real-time estimation of rainfall intensity and areal rainfall.

  • PDF

Noise PDF Analysis of Nonlinear Image Sensor Model with Application: Iterative Radiometric Calibration Method

  • Myung, Hwan-Chun;Youn, Heong-Sik
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.247-250
    • /
    • 2008
  • The paper presents the advanced radiometric calibration method, called the lRCM (Iterative Radiometric Calibration Method), in order to avoid an operational constraint (solar source) for calibration. The IRCM assumes that an optical instrument is equipped with a filter assembly which consists of same band filters with different transmission ratios. Given all the noise sources (including the artificial one caused by the filters) of an image sensor, the noncentral ${\chi}^2$ distribution of the output result is induced by the approach of a noise PDF (Power Density Function). Finally, the radiometric calibration problem is transformed into equating two independent relations for the image sensor gains through the specified distribution.

  • PDF

Surrogate based model calibration for pressurized water reactor physics calculations

  • Khuwaileh, Bassam A.;Turinsky, Paul J.
    • Nuclear Engineering and Technology
    • /
    • 제49권6호
    • /
    • pp.1219-1225
    • /
    • 2017
  • In this work, a scalable algorithm for model calibration in nuclear engineering applications is presented and tested. The algorithm relies on the construction of surrogate models to replace the original model within the region of interest. These surrogate models can be constructed efficiently via reduced order modeling and subspace analysis. Once constructed, these surrogate models can be used to perform computationally expensive mathematical analyses. This work proposes a surrogate based model calibration algorithm. The proposed algorithm is used to calibrate various neutronics and thermal-hydraulics parameters. The virtual environment for reactor applications-core simulator (VERA-CS) is used to simulate a three-dimensional core depletion problem. The proposed algorithm is then used to construct a reduced order model (a surrogate) which is then used in a Bayesian approach to calibrate the neutronics and thermal-hydraulics parameters. The algorithm is tested and the benefits of data assimilation and calibration are highlighted in an uncertainty quantification study and requantification after the calibration process. Results showed that the proposed algorithm could help to reduce the uncertainty in key reactor attributes based on experimental and operational data.

Absolute Radiometric Calibration for KOMPSAT-3 AEISS and Cross Calibration Using Landsat-8 OLI

  • Ahn, Hoyong;Shin, Dongyoon;Lee, Sungu;Choi, Chuluong
    • 한국측량학회지
    • /
    • 제35권4호
    • /
    • pp.291-302
    • /
    • 2017
  • Radiometric calibration is a prerequisite to quantitative remote sensing, and its accuracy has a direct impact on the reliability and accuracy of the quantitative application of remotely sensed data. This paper presents absolute radiometric calibration of the KOMPSAT-3 (KOrea Multi Purpose SATellite-3) and cross calibration using the Landsat-8 OLI (Operational Land Imager). Absolute radiometric calibration was performed using a reflectance-based method. Correlations between TOA (Top Of Atmosphere) radiances and the spectral band responses of the KOMPSAT-3 sensors in Goheung, South Korea, were significant for multispectral bands. A cross calibration method based on the Landsat-8 OLI was also used to assess the two sensors using near simultaneous image pairs over the Libya-4 PICS (Pseudo Invariant Calibration Sites). The spectral profile of the target was obtained from EO-1 (Earth Observing-1) Hyperion data over the Libya-4 PICS to derive the SBAF (Spectral Band Adjustment Factor). The results revealed that the TOA radiance of the KOMPSAT-3 agree with Landsat-8 within 5.14% for all bands after applying the SBAF. The radiometric coefficient presented here appears to be a good standard for maintaining the optical quality of the KOMPSAT-3.

정확한 GPS 기준국 좌표산출을 위한 위상중심 변동량 계산방법 비교 (Comparison of Calibration Methods of Phase Center Variations for Precise GPS Monument Positioning)

  • 원지혜;박관동;하지현;김상호
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.9-14
    • /
    • 2006
  • A determinated position with GPS (Global Positioning System) data processing is the position of the phase center of a GPS antenna. The phase center of a GPS antenna is. not a stable point and depends on the azimuth and elevation angles of GPS satellites. It is known that the phase center variations (PCV) of a GPS antenna are greater in the vertical than the horizontal directions. The PCV calibration models for a GPS. antenna has two approaches: relative and absolute. In this study. we compared the two calibration models using the six operational permanent GPS stations in South Korea and analysed the PCV of each station. In addition, we. tested two different kinds of GPS antennas and compared the results. The accuracy and precision of the relative calibration was worse than the absolute calibration.

  • PDF

지구관측용 마이크로파 위성센서의 검보정 연구 동향 (Research Trend of Calibration Methods on the Satellite Microwave Sensors)

  • 진경욱;양군호
    • 항공우주산업기술동향
    • /
    • 제8권1호
    • /
    • pp.33-44
    • /
    • 2010
  • 이 논문에서는 지구관측용 위성에 장착된 마이크로파 센서들의 검보정법에 대해 조사, 기술하였다. 아울러 현재 운영 중이거나 이러한 미션들을 대체하여 향후 진행될 대표적인 지구관측 미션들을 소개하였다. 보다 효과적인 이해를 위해 지구 관측 미션들을 중심으로 이들 위성에 장착된 마이크로파 센서들의 검보정법을 설명하면서, 센서들의 중요한 특징들과 주요 임무에 대해서 요약 정리하였다.

  • PDF

아날로그-디지털 전달함수 평균화기법 기반의 Cyclic ADC의 디지털 보정 기법 (Digital Calibration Technique for Cyclic ADC based on Digital-Domain Averaging of A/D Transfer Functions)

  • 엄지용
    • 전자공학회논문지
    • /
    • 제54권6호
    • /
    • pp.30-39
    • /
    • 2017
  • 본 논문은 디지털영역에서의 평균화 기법을 이용한 cyclic ADC의 디지털 보정기법을 제안한다. 제안하는 보정기법은 1.5비트 MDAC의 커패시터 부정합으로 인해 발생하는 ADC의 비선형성을 보정한다. 부정합을 지니는 커패시터로 이루어진 1.5비트 MDAC은 이상적인 1.5비트 MDAC의 레지듀 플롯(residue plot)에 대해 대칭적인 레지듀 플롯을 지닌다. 커패시터 부정합을 지니는 1.5비트 MDAC의 고유한 레지듀 플롯은 대칭적인 아날로그-디지털 전달함수로 반영된다. 이상적인 아날로그-디지털 전달함수에 대해 대칭적인 두 아날로그-디지털 전달함수를 평균화함으로써, 비선형성이 보정된 아날로그-디지털 전달함수를 얻을 수 있다. 해당 아날로그-디지털 전달함수 평균화의 구현을 위해, 본 논문의 12비트 cyclic ADC는 1.5비트 MDAC의 동작 모드를 2개로 정의한다. 해당 cyclic ADC는 MDAC을 첫 번째 동작모드로 동작시킴으로써, 비선형성을 지니는 12.5비트 출력 코드를 획득한다. 샘플링 된 동일한 입력 아날로그 전압에 대해, MDAC을 두 번째 동작모드로 동작시킴으로써, cyclic ADC는 비선형성을 지니는 또 다른 12.5비트 출력 코드를 획득한다. 각 MDAC의 동작모드에 의해 발생하는 아날로그-디지털 전달함수는 이상적인 아날로그-디지털 전달함수에 대해 대칭적이기 때문에, 앞서 획득한 두 개의 비선형성을 지니는 12.5비트를 평균화함으로써, 비선형성이 보정된 최종 12비트 출력 코드를 획득할 수 있다. 제안하는 디지털 보정기법과 12비트 cyclic ADC는 $0.18-{\mu}m$ CMOS 공정을 이용하여 full-custom 형식으로 구현되었다. 측정된 SNDR(ENOB)와 SFDR은 각각 65.3dB(10.6비트 ENOB)와 71.7dB이다. 측정된 INL과 DNL은 각각 -0.30/+0.33LSB와 -0.63/+0.56LSB이다.

구조-음향 상반성 원리를 이용한 공기기인 소음원의 강도 추정 및 소음 합성 (The Use of Vibro-acoustical Reciprocity to Estimate Source Strength and Airborne Noise Synthesis)

  • 김윤재;변재환;강연준;홍진철;권오준;강구태
    • 한국소음진동공학회논문집
    • /
    • 제19권1호
    • /
    • pp.42-49
    • /
    • 2009
  • In this paper, an alternative method was introduced to conduct a transfer path analysis for airborne noise. The method used the transfer function matrix composed of acoustic transfer functions that are referenced by the input voltage of a calibration source. A calibration factor which is converting a virtual voltage to source strength was deduced by vibro-acoustical reciprocity theorem. The calibration factor is then multiplied to the virtual input voltage to estimate the operational source strength. Three loudspeakers were used to noise sources of acrylic half car model. The method was applied to airborne noise transfer path analysis of the half car. The estimated source strength by transfer path analysis was compared the deduced source strength by vibro-acoustical reciprocity to verify the method.

자동 트랜스퍼 크레인의 위치보정 시스템 (Position Calibration System of Automatic Transfer Crane)

  • 박경택;박찬훈;신영재;강병수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.515-520
    • /
    • 2002
  • Automatic Transfer Crane is needed for automation of container terminal. It requires the control capability of exact position for loading/unloading job in yard. But it has the limitation of improvement because it has the operational environmental and its structural problems. It has the positioning errors caused by the deformation of rail, yawing motion of crane, wear of wheel, sliding motion between wheel and rail and so on. This study shows the calibration method of crane position by using the primitivity sensor and calibrating plate fixed on the ground.

  • PDF

Structural monitoring of a wind turbine steel tower - Part I: system description and calibration

  • Rebelo, C.;Veljkovic, M.;da Silva, L. Simoes;Simoes, R.;Henriques, J.
    • Wind and Structures
    • /
    • 제15권4호
    • /
    • pp.285-299
    • /
    • 2012
  • This paper describes the development and calibration of a structural monitoring system installed in a 80 meters high steel wind tower supporting a 2.1 MW turbine Wind Class III IEC2a erected in the central part of Portugal. The several signals are measured at four different levels and include accelerations, strains on the tower wall and inside the connection bolts, inclinations and temperature. In order to correlate measurements with the wind velocity and direction and with the turbine operational parameters the corresponding signals are obtained directly from the turbine own monitoring system and are incorporated in the developed system. Results from the system calibration, the structural identification and the initial period of data acquisition are presented in this paper.