• Title/Summary/Keyword: on-site testing

Search Result 453, Processing Time 0.032 seconds

Analysis on Consolidation Behavior of Soft Ground with Reactive Drain Pile (반응성 배수파일이 타설된 지반의 압밀거동 분석)

  • Kim, Beomjun;Oh, Myounghak;Yune, Chanyoung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.13-23
    • /
    • 2014
  • Geotechnical evaluation on the reactive drain pile which can achieve simultaneously both the soft ground improvement and the remediation of contaminated pore water in reclamation site was performed. Applicability of steel-making slag used as a inside reactive material was confirmed. To investigate the consolidation characteristics of the soft ground improved by reactive drain pile, testing devices to form and install the reactive drain pile were developed and laboratory tests were performed according to the existence of outside sand drain and the length of impermeable barrier. Test results showed that the consolidation time was decreased as the shortening of impermeable barrier. However, the effect of outside sand drain on consolidation time was dominant compared with the length of impermeable barrier.

An Experimental Study on the Compressive Strength of High Strength Concrete According to Testing Condition (시험조건과 고강도콘크리트의 압축강도 관계에 관한 실험적 연구)

  • Chin, Young-Gil;Lee, Yong-Su;Kim, Kwang-Seo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.2
    • /
    • pp.129-134
    • /
    • 2002
  • The strength and durability of concrete are affected by various factors such as the quality of material, mixing ratio, construction, the method of cure, time elapsed. the condition of test and etc., it is very difficult to pre-estimate the strength of concrete with the use of experimental specimen. The domestic standard of specimen cylindrical type and its sizes are both l0cm$\times$20cm and 15cm$\times$30cm, which are prescribed in KS F2405, and the loading speed is prescribed to test with 2~3kgf/$\textrm{cm}^2$ per second. The loading speed should have great effect on the compressive strength, but in reality in the construction site sometimes the loading speed is applied so dubiously that the value of the compressive strength can be unreliable. And the cross sectional area of a specimen should be level and smooth, otherwise it can be broken at a lower stress than the real strength through the eccentric or intensive working of the load. Capping should be carried out in order to measure the strength correctly. And used for capping are various materials such as capping compound, cement glue, plaster, mechanical grinding and etc. In this study, therefore, I have carried out an experiment on the relationship among the loading speed, the ratio of height to diameter of specimen, the method of capping, and the compressive strength, for the efficient quality control of concrete structures. So this study has been purposed to provide some basic data that can be used effectively at construction sites.

Estimation of Drilling Velocity for Horizontal Wells Based on Alluvial Sediment Characteristics (충적층 입자 특성을 고려한 수평집수정 굴착 속도 추정)

  • Kim, Gyoo-Bum;Lee, Jeong-Woon;Lee, Chi-Hyung
    • The Journal of Engineering Geology
    • /
    • v.25 no.2
    • /
    • pp.273-280
    • /
    • 2015
  • Delays in horizontal well drilling when encountering heterogeneous sediments can have negative effects on the construction process at a riverbank filtration site. Grain size analysis, including calculation of the coefficient of uniformity and the coefficient of curvature, was conducted on soil samples collected at each drilling depth during the process of drilling horizontal wells. These results were then used to develop a linear equation for estimating drilling velocity using the coefficient of uniformity and the coefficient of curvature as inputs. Testing of the linear equation in other horizontal wells indicates that the equation is most appropriate for coarse-sand-sized and well-sorted sediment. Because this study was conducted in a region with small- to medium-sized streams, more data are needed from larger rivers to modify the general equation. Our results will provide better estimates of drilling velocity, in turn enabling more detailed design and more effective construction management at riverbank filtration sites.

Application of Fault Current Limiter in 22.9kV KEPCO power distribution line (22.9kV 지중선로용 한류기 한전 실계통 시범적용)

  • Kim, Min Jee;Park, Kyungwon;Ahn, Kil-Young;Kim, Young-keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1034-1035
    • /
    • 2015
  • Watertight 25.8 kV/600 A/12.5 kA fault current limiters (FCLs) have successfully installed in five areas (Incheon, Seoul, Gyeong-gi, Daejeon, Suwon) on KEPCO power distribution line for the purpose of commercial demonstrations. The fault current limiting operation of this FCL, which includes functions of sensing, commutation, and reduction of fault currents, is perfectly completed within 1 cycle immediately after fault occurs. The performance of FCL was verified by short circuit test, impedance test, insulation test, temperature-rise test, and control test, etc at PT&T in LS industrial systems, which is the official certification institute in Korea. In 2013, and also the FCL field test was performed in order to test the protection coordination between conventional relays and FCL, on the 1.5 kA and 5.0 kA faults, which were made by connecting the Artificial Fault Generator (AFG) to the distribution line in test grid at KEPCO Power Testing Center. The next step of this project is to check the FCL conditions caused by real external environment, and acquire the various data from five regions installed with FCL. In this paper, we intend to explain the FCL specifications and performance characteristics, and check the expected effect by application of FCL to power distribution line based on the power system analysis of an application site.

  • PDF

Development of Stochastic-Dynamic Channel Routing Model by Storage Function Method (저류함수법에 의한 추계동역학적 하도홍수추적모형의 개발)

  • Bae, Deok-Hyo;Jeong, Il-Mun
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.3
    • /
    • pp.341-350
    • /
    • 2000
  • The objectives of this study are to develop a state-space form of stochastic dynamic storage function routing model and to test the model performance for real-time flow forecast. The selected study area is the main Han River starting from Paldang Dam site to Indogyo station and the 13 flood events occurred from 1987 to 1998 are selected for computing model parameters and testing the model performance. It was shown that the optimal model parameters are quite different depending on Hood events, but the values used on field work also give reasonable results in this study area. It is also obvious that the model performance from the stochastic-dynamic model developed in this study gives more accurate and reliable results than that from the existing deterministic model. Analysis for allowable forecast lead time leads that under the current time step the reasonable predicted downstream flows in 5 hours time advance are obtained from the stochastic dynamic model on relatively less lateral inflow event in the study area.

  • PDF

A Study on the Development of an Education and Training System for Civil Servant Librarians (사서직공무원 교육훈련 시스템 발전 방안 연구)

  • Lee, Shin-Ho;Yang, Hae-Sool
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.22 no.4
    • /
    • pp.91-113
    • /
    • 2011
  • This study aims to devise reasonable future-oriented librarian training program development plan for satisfying on-site demands of librarians nationwide by examining and finding out the operation of managing the nation's only one librarian training program of National Library of Korea. Based on a survey targeting 2,044 people participating in training program, meeting of interested persons, doing self-operation rating, it tries to find problems of training programs, examine ways to improve them and suggests solutions such as reforming of exclusively designed organization for educating, training of lectures, increasing training budget, promoting cyber training and balancing the testing systems. In addition, as part of improving librarian training programs, it considers Sejong National Library(currently being constructed) to be responsible for sharing its work and management.

Study on Characteristics of In-situ Rock Stress State in Mountainous Region by Hydraulic Fracturing Method (수압파쇄시험에 의한 산악지역에서의 현지 암반 초기응력 측정 및 분포특성 연구)

  • Bae, Seong-ho;Jeon, Seok-won;Choi, yong-kun;Kim, Hak-soo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.1
    • /
    • pp.57-70
    • /
    • 2002
  • Since early in the 90's, the need for construction of underground rock structures such as long and large section traffic tunnel, energy storage cavern, industrial facility, etc. has been largely increased because the Korean territory is not wide and about 65 % of the land consists of mountainous region. The initial rock stress measurement has been widely conducted to provide the quantitative information on the stress state of engineering site at the design stage of underground rock structures. Among the diverse methods developed for measuring rock stress, hydraulic fracturing test is most popularly used because it is applicable at pre-construction stage and has no limit in testing depth. In this paper, the characteristics of initial rock stress state in mountainous region were studied on the basis of the in-situ hydraulic fracturing stress measurement results from the 60 test boreholes in various parts of Korea.

  • PDF

Single-dose Toxicity of Water-soluble Ginseng Pharmacopuncture Injected Intramuscularly in Rats

  • Yu, Junsang;Sun, Seungho;Lee, Kwangho;Kwon, Kirok
    • Journal of Pharmacopuncture
    • /
    • v.18 no.2
    • /
    • pp.76-85
    • /
    • 2015
  • Objectives: Radix Ginseng has been traditionally used as an adaptogen that acts on the adrenal cortex and stimulates or relaxes the nervous system to restore emotional and physical balance and to improve well-being in cases of degenerative disease and/or old age. Radix Ginseng has been used for a long time, but the safety of ginseng pharmacopuncture needs testing. This study was done to analyze the single-dose toxicity of water- soluble ginseng pharmacopuncture (GP) intramuscular injections in rats. Methods: All experiments were performed at Biotoxtech, an institution authorized to perform non clinical studies under the regulations of Good Laboratory Practice (GLP). Each group contained 10 Sprague-Dawley rats, 5 males and 5 females. GP was prepared in a sterile room at the Korean Pharmacopuncture Institute under regulations of Good Manufacturing Practice (GMP). GP dosages were 0.1, 0.5 and 1.0 mL for the experimental groups; normal saline was administered to the control group. The animals general condition was examined daily for 14 days, and the rats were weighed on the starting day and at 3, 7 and 14 days after administration of the pharmacopuncture. Hematological and biochemistry tests and autopsies were done to test the toxicological effect of GP after 14 days. This study was performed with approval from the Institutional Animal Ethics Committee of Biotextech. Results: No deaths were found in this single-dose toxicity test of intramuscular injections of GP, and no significant changes in the general conditions, body weights, hematological and biochemistry tests, and autopsies were observed. The local injection site showed no changes. Based on these results, the lethal dose was assumed to be over 1.0 mL/animal in both sexes. Conclusion: These results suggest that GP is relatively safe. Further studies, including a repeated toxicity test, are needed to provide more concrete evidence for the safety of GP.

A study on the improvement of cleaning performance in bag-filter (여과집진기의 탈진 거동 개선에 관한 연구)

  • Hong, Sung-Gil;Kum, Young-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1571-1578
    • /
    • 2015
  • The cleaning characteristics of pulse air jet type cleaning system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the cleaning performance in modified shape of dedusting unit was compared in this study. The review on each shape of cleaning part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1). Also, the optimal venturi shape was designed and examined its applicability to the site in a pilot scale plant. A combined system of a blow tube and a venturi proposed by this study turned out to be very effective for concentrating an cleaning air compared to existing systems, such as using only blow tube and combines the blow tube and venturi. In addition, as a result of installing and testing a venturi proposed by this study, the cleaning frequency and cleaning time were much improved compared to a case of using a commercial venturi that is under use at the industrial sites.

Comparative field tests on uplift behavior of straight-sided and belled shafts in loess under an arid environment

  • Qian, Zeng-zhen;Lu, Xian-long;Yang, Wen-zhi;Cui, Qiang
    • Geomechanics and Engineering
    • /
    • v.11 no.1
    • /
    • pp.141-160
    • /
    • 2016
  • This study elucidates the uplift behaviors of the straight-sided and belled shafts. The field uplift load tests were carried out on 18 straight-sided and 15 belled shafts at the three collapsible loess sites under an arid environment on the Loess Plateau in Northwest China. Both the site conditions and the load tests were documented comprehensively. In general, the uplift load-displacement curves of the straight-sided and belled shafts approximately exhibited an initial linear, a curvilinear transition, and a final linear region, but did not provide a well defined peak or asymptotic value of the load, and therefore their uplift resistances should be interpreted from the load test results using an appropriate criterion. Nine representative uplift resistance interpretation criteria were used to define the "interpreted failure load" for each of the load tests, and all of these interpreted uplift resistances were normalized by the failure threshold, $T_{L2}$, obtained using the $L_1-L_2$ method. These load test data were compared statistically and graphically. For the straight-sided and belled shafts, the normalized uplift load-displacement curves were respectively established by the plots that related the mean interpreted uplift resistance ratio against the mean displacement at the corresponding interpreted criteria, and the comparisons of the normalized load-displacement curves were made. Specific recommendations for the designs of uplift belled and straight-sided shafts in the loess were given, in terms of both capacity and displacement.