• 제목/요약/키워드: on-line measurement

검색결과 1,876건 처리시간 0.034초

급전선로에 설치되어 있는 피뢰기의 누설전류 측정과 관리방안 (Leakage Current Measurement and Management of Arresters Installed in Feeder Lines)

  • 한주섭;서황동;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.819-824
    • /
    • 2005
  • This paper describes the measurement result of leakage current flowing arresters connected in feeder lines to propose an optimal management method. Twenty seven arresters set in seven areas were analyzed on a regular basis for 4 months. The results showed that the RMS and the peak value of the total leakage currents for soundness arresters were a range of $200uA{\sim}00uA$. respectively. During the period of measurement, the magnitude of the leakage current didn't show conspicious changes and there were impossible places to analyze arrester's status due to including high THD rate in a feeder line, From the study, leakage current measurement has to be performed at a condition without running an electric train in the line, and the allowable RMS value of soundness arrester is bellow 600uA.

  • PDF

Power line phasor 측정 오차 해석 연구 (Analysis of power line phasor measurement error)

  • 김병일;장태규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.367-368
    • /
    • 2006
  • This paper presents an analytic derivation of phase measurement error. The analysis derives the measurement error caused by the finite-bit quantization of both input signals and twiddle factors used in the recursive implementation of the phasor measurement algorithm. The derivation is based on the statistical exploration of the error dynamic equations. The effect of frequency deviation and the number of DFT points are also included in the study. The analysis results are verified with the data obtained from the computer simulation by widely varying the values of error causing factors.

  • PDF

선로변 전차선과 조가선의 전류를 이용한 집전성능 분석 기술 (Analysis of Current Collection Performance using Real-time Measurement of Current for Overhead Contact Line on the Track-side)

  • 박영;신승권;이기원;김재문;김원하
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.573-576
    • /
    • 2013
  • In this paper, analysis method for current collection performance based on real-time current of catenary system is proposed. An innovative method based on track-side of railway system is used for measurement of currents for overhead contact line during the collection with pantograph. The evaluation of a qualitative ratio for current collection performance were conducted using proposed algorithm under various conditions such as laboratory and track-side. To check the validity of our approach, we compared between calculation results from current of contact wire and measurement results from arcing of pantograph using simulator in laboratory conditions. The results show that the behavior of current collection performance were analysis from currents of overhead contact line in AC electric railway system.

서지 보호기의 열화 특성과 온라인 진단장치 (Deterioration Characteristics and an On-Line Diagnostic Equipment for Surge Protective Devices)

  • 박경수;왕국명;황성철;김선재;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.635-640
    • /
    • 2016
  • This paper dealt with the deterioration characteristics and an on-line diagnosis equipment for SPDs (surge protective devices). An accelerated aging test was carried out using a $8/20{\mu}s$ standard lightning impulse current to analyze the changes of electrical characteristics and to propose the diagnostic parameters and the criterion for deterioration of ZnO varistor which is the core component of SPDs. Based on the experimental results, an on-line diagnosis equipment for SPD was fabricated, which can measure the total leakage current, reference and clamping voltage. The leakage current measurement circuit was designed using a low-noise amplifier and a clamp type ZCT. A linear controller, the leakage current measurement part and a HVDC were used in the measurement of reference voltage. The measurement circuit of clamping voltage consisted of a surge generator and a coupling circuit. In a calibration process, measurement error of the prototype equipment was less than 3%.

고압 회전기 On-line 부분방전 측정용 Ceramic Coupler 특성 (Characteristics of Ceramic Coupler for On-line Partial Discharge Measurement in High Voltage Rotating Machines)

  • 강동식;윤대희;김용주;이홍식;윤영호;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.204-212
    • /
    • 2002
  • In order to improve the reliability of high voltage rotating machines, it is necessary to understand the breakdown mechanism of stator windings. Especially partial discharge(PD) inception and growth are important in stator winding insulation. Recently, many research on the diagnosis of stator winding insulation for large rotating machines have been developed since the 1970s. Capacitive couplers have been the most widely used sensor for on-line partial discharge detection in rotating machines. This paper deals with the electrical on-line monitor characteristics of ceramic coupler(CC) which has been developed to continuously measure the PD activity in operating high voltage motor stator windings on site. We investigated the electrical characteristics(PD quantity, breakdown voltage and frequency response) to develop CC. This paper presents frequency characteristics and laboratory test result to compare conventional 80([F] epoxy-mica coupler(EMC) and 105[pF] CC for PD measurement with 6.6㎸ model stator windings.

스캔라인 영상분할기법에 의한 정밀도 측정에 관한 연구 (Precision Measurement using Scan-line image Segmentation Method)

  • 박정수;윤재웅;정원
    • 한국산업정보학회논문지
    • /
    • 제7권4호
    • /
    • pp.29-36
    • /
    • 2002
  • 본 연구에서는 영상분할기법을 이용한 스캔라인기법에 기초하여 영역 이미지의 새로운 에지 결합방식을 제시한다. 본 논문에서 제시한 기존 알고리즘은 3차원 영상을 2차원 영상으로 적용하는 과정에서 깊이의 정보, 조명등의 영향으로 심한 잡음이 발생하여 이로 인해 정밀측정에 많은 어려움이 있었다. 기존의 스캔라인기법은 광원에 의해 직선추출의 형상인식에서만 활용하였으나 이를 원호에 적용 정밀측정 하였다. 본 연구로 인한 오프라인(Off-line)의 검사방식을 온라인(On-line) 방식에서도 정밀측정이 가능함을 입증하였다.

  • PDF

Running Characteristics for On-Line Test of Railway Vehicle

  • Han, Young-Jae;Kim, Seog-Won;Seo, Sung-Il;Mok, Jin-Yong;Lee, Su-Gil;Kim, Young-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1347-1350
    • /
    • 2005
  • Recently, as the road capacity reaches a limit and environmental problems become serious, there exists a gradual increasing need for railway vehicles that are environment-friendly, punctual, reliable and safe. Accordingly, in addition to conventional railroad vehicles, lots of vehicles are being newly developed. Using the developed installed measurement system, the performance characteristics of railway vehicle could be monitored precisely. After recording the input real time data of each signal from railway vehicle to the network line, we could acquire the needed information through post processing program. We could verify the running performances of railway vehicle using this system. As a result, many latent defects have been found and corrected in the prototype train. The measurement systems have contributed to dramatic reduction of the developing period.

  • PDF

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권1호
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.