• Title/Summary/Keyword: on-device

Search Result 19,601, Processing Time 0.044 seconds

A Study for the Improvement of the Classification Number as the Search Device on the Library Homepage (도서관 홈페이지에서 분류기호 탐색장치의 개선방안 연구)

  • Kim, Ja-Hoo
    • Journal of Korean Library and Information Science Society
    • /
    • v.39 no.4
    • /
    • pp.215-235
    • /
    • 2008
  • The purpose of this study aims to provide possible suggestions for the improvement of the literature classification number system as the search and browsing device on the library homepage. After analyzing and evaluating literature classification number system as the search and browsing device on the homepage of library adopting DDC, suggestions for the improvement were proposed. For the purpose of maximizing the effectiveness of literature classification number system as the browsing device, DDC third summary(the thousand section) which is suited to domestic circumstances was prepared.

  • PDF

Fabrication and Reliability Test of Device Embedded Flexible Module (디바이스 내장형 플렉시블 전자 모듈 제조 및 신뢰성 평가)

  • Kim, Dae Gon;Hong, Sung Taik;Kim, Deok Heung;Hong, Won Sik;Lee, Chang-Woo
    • Journal of Welding and Joining
    • /
    • v.31 no.3
    • /
    • pp.84-88
    • /
    • 2013
  • These days embedded technology may be the most significant development in the electronics industry. The study focused on the development of active device embedding using flexible printed circuit in view of process and materials. The authors fabricated 30um thickness Si chip without any crack, chipping defects with a dicing before grinding process. In order to embed chips into flexible PCB, the chip pads on a chip are connected to bonding pad on flexible PCB using an ACF film. After packaging, all sample were tested by the O/S test and carried out the reliability test. All samples passed environmental reliability test. In the future, this technology will be applied to the wearable electronics and flexible display in the variety of electronics product.

A Study on Electromagnetic Interference of Electric Vehicles with Variations of Charging Device Inlet Location (전기자동차 충전구 위치에 따른 전자파 방사특성에 관한 연구)

  • Gwon, Sunmin;Woo, Hyungu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.694-701
    • /
    • 2016
  • According to revolutionary developments in automobile technologies, eco-friendly advanced vehicles (hybrid vehicle, hydrogen fuel-cell vehicle, electric vehicle, etc.) are rapidly increasing. The electromagnetic compatibility is getting more important for development of a vehicle because those advanced vehicles are driven by electric energy and equipped with more electric systems. In general, electromagnetic compatibility tests consist of an electromagnetic interference(EMI) test and an electromagnetic susceptibility(EMS) test. EMI test of the electric vehicles are needed not only in driving mode but also in charging mode because they must be recharged by much electric energy for driving. Depending on vehicle manufacturers, the charging device type and the location of charging device inlet in electric vehicles are various. In this paper, in order to investigate EMI of electric vehicles in charging mode in consideration of the direction of measuring antenna and the location of charging device inlet, a series of electromagnetic emission tests are conducted using three electric vehicles (neighborhood electric vehicle, electric vehicle and electric vehicle-bus). The test results show that electromagnetic emission measurements in charging mode are dependent on the direction of measuring antenna and the location of charging device inlet.

Fabrication and Experiment of Ultrasonic Sensor Integrated Motion Recognition Device for Vehicle Manipulation (초음파 센서를 이용한 모션 인식 차량 통합 제어 장치의 제작 및 실험)

  • Na, Yeongmin;Park, Jongkyu;Lee, Hyunseok;Kang, Taehun
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • Worldwide, studies on intelligent vehicles for the convenience of drivers have been actively conducted as the number of cars has increased. However, vehicle convenience enabled by buttons lowers the concentration on driving and hence poses as a huge threat to the safety of the driver. The use of one of the convenient features, impaired driving auxiliary equipment, is limited because of its complex usage, and this device also hinders the front view of the driver. This paper proposes a vehicle-control device for controlling the convenient features as well as changes in speed and direction using gestures and motions of the driver. This device consists of an ultrasonic sensor for recognizing movement, an arduino for accepting signal control functions and servo and DC motors apply to various vehicle parts. Firstly, the vehicle-control device was designed using a 3D CAD program known as Solid-works based on the size of the steering wheel. Then, through simulations, a suitable length for minimizing the absorbent between ultrasonic sensors was confirmed using a program known as COMSOL Multiphysics. Finally, simulation results were verified through experiments, and the optimal size of the device was identified through the number of errors.

Impedance Calculation of an Underground Transmission Cable System Installed with a Sheath Current Reduction Device

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Wang, Xin Heng;Song, Yong Hua
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.236-242
    • /
    • 2004
  • Previous research results indicated that the designed current reduction device could effectively reduce the sheath circulating current and that its RDP protection device could shield it against both fault and lightning strokes. In this paper, cable impedance is analyzed using wavelet analysis and distance relay algorithm following the installation of these devices so that the operation of distance relay can be estimated. The test results confirm that in these devices, the fault inception angle and SVL bonding types have no impact on the change of cable impedance. In other words, the conventional distance relay can be used without a new relay setting. Thus we can finally assert that the designed current reduction device and its protection device are effective and can be safely installed on the cable transmission system without disturbance.

Simplified Parametric Study on M125 Booster Mechanism and its Application for Determining the Characteristic Constant of Arming Distance (M125 부스터 메카니즘의 해석 및 응용)

  • Rim, One kwon;Kim, Sung shik;Bang, Jae won
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.409-414
    • /
    • 2015
  • M125 booster is one of the reliable S&A device(safety and arming device) to determine the arming distance of fuze for gun ammunitions from 90 mm to 8 inch in diameter. And it is also well known that the arming distance of M125 booster is determined by the multiplication value of the gun tube property(traveled distance per turn of projectile) and the S&A device property(number of turns to arm), not by the projectile muzzle velocity. We have tried and succeeded in executing a proper analysis on M125 booster to figure out its characteristic constant of arming distance by considering only the gun tube properties and the S&A device properties. More detailed arming distance will be analyzed in the future by considering dynamic characteristics on all elements in the S&A device with vector analysis.

Development of Brace-type Wearable Robot for Lumbar Stabilization (요부 안정화를 위한 복대형 입는 로봇 개발)

  • Joowan Kim;Jaehoon Sim;Keewon Kim;Sungun Chung;Jaeheung Park
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.2
    • /
    • pp.189-196
    • /
    • 2023
  • An abdominal brace is a recommended treatment for patients with lumbar spinal disorders. However, due to the nature of the static brace, it uniformly compresses the lumbar region, which can weaken the lumbar muscles or create a psychological dependence that worsens the condition of the spine when worn for an extended period of time. Due to these issues, doctors limit the wearing time when prescribing it to patients. In this paper, we propose a device that can dynamically provide abdominal pressure and support according to the lumbar motion. The proposed device is a wearable robot in the form of a brace, with actuators and a driving unit mounted on the brace. To enhance wearability and reduce the weight of the device, worm gears actuator and a multi-pulley mechanism were adopted. Based on the spinal motion of the wearer measured by the Inertia measurement unit sensors, the drives wire by driving pulley, which provide tension to the multi-pulley mechanism on both sides, dynamically tightening or loosening the device. Finally, the device can dynamically provide abdominal pressure and support. We describe the hardware and system configuration of the device and demonstrate its potential through basic control experiments.

Investigating the effect of changing parameters in the IEC device in comparative study

  • H. Ghammas;M.N. Nasrabadi
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.292-300
    • /
    • 2024
  • Kinetic simulations have been performed on an Inertial Electrostatic Confinement Fusion (IECF) device. These simulations were performed using the particle-in-cell (PIC) method to analyze the behavior of ions in an IEC device and the effects of some parameters on the Confinement Time (CT). CT is an essential factor that significantly contributes to the IEC's performance as a nuclear fusion device. Using the PIC method, the geometry of a two-grided device with variable grid radius, the number of cathode grid rings, variable pressure and different dielectric thickness for the feed stalk was simulated. In this research, with the development of previous works, the interaction of particles was simulated and compared with previous results. The simulation results are in good agreement with the previous results. In these simulations, it was found that with the increase of the dielectric thickness of the feed stalk, the electric field was weakened and as a result, the confinement time was reduced. On the other hand, with the increase of the cathode radius, the confinement time increased. Using the results, an IEC device can be designed with higher efficiency and more optimal CT for ions.

Implementation of UPnP Device based on Embedded Linux using ARM9 Platform (ARM9 Platform을 이용한 Embedded Linux 기반의 UPnP Device의 구현)

  • Lee, Hui-Jeong;Jeong, Jin-Gyu;Jin, Seon-Il;Hong, Seok-Gyo
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.754-757
    • /
    • 2003
  • The implementation of home network systems In ubiquitous computing environments requires middleware that provides a method to control and operate home appliance devices. The Universal Plug and Play (UPnP), which is based on the IPv4 protocol and running on a PC, consists of UPnP devices that provide relevant services and control points that control the devices. However, It is inappropriate to Implement UPnP devices on a PC, since the implementation on a PC requires much space and electrical power. In this paper, a small embedded home network device equipped with UPnP middleware is implemented on an embedded GNU/Linux system running on an ARM9 platform, in order to deal with such problems.

  • PDF

The Design and Implementation of Frequency Domain Sampling Surface Acoustic Wave Sensor Platform (Frequency Domain Sampling 방식의 Surface Acoustic Wave Sensor Platform 설계 및 구현)

  • Joh, Yool-Hee;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.220-223
    • /
    • 2012
  • Generally, SAW device, which uses Time Domain Sampling, requires high speed AD converter because SAW device (TDS) needs high sampling speed as much as its high data speed. However, the high price of AD converter discourages makers from using it. On the other hand, SAW device, which uses Frequency Domain Sampling, does not required high speed AD converter because SAW device (FDS) does not need high sampling speed. It is very efficient in price comparison to its performance because high processing speed of SAW device (FDS) can be implemented using low price Embedded Systems. The purpose of the thesis is to solve the issues above by designing and realizing SAW device (FDS) using SAW sensor for TDS.

  • PDF