• Title/Summary/Keyword: odor

Search Result 1,894, Processing Time 0.025 seconds

Experimental Study on Hydrogen Sulfide Abatement in Sewage Odor Using Microbial Deodorants on the Market (시판용 미생물탈취제를 이용한 하수 악취 내 황화수소 저감에 관한 실험적 연구)

  • Park, Sang Jin;Kwon, Soo Youl
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.2
    • /
    • pp.170-183
    • /
    • 2020
  • Objectives: This study was conducted to estimate a technology to reduce hydrogen sulfide (H2S) in sewage odor using microbial deodorant. Methods: After injecting five commercially available microbial deodorants into fresh sewage, the concentration of hydrogen sulfide over time was measured using the headspace method. H2S concentration in odor samples was measured using gas chromatograph/FPD. Calculated odor concentration and calculated odor intensity by H2S concentration remaining after treatment with microbial deodorant were evaluated theoretically. Results: The rate of H2S abatement by microbial deodorant differed depending on the experimental conditions and the type of deodorant, but it was found to range from 63 to 82%. Especially, two deodorants showed high H2S reduction rates of over 80% on average. However, based on the best deodorant, the theoretically calculated odor concentration by H2S after microbial deodorant treatment was 4,400 OUk, and the theoretical odor intensity was also rated at 4 degrees or higher. Conclusions: In conclusion, microbial deodorant is considered to have a relatively high effect on reducing H2S in sewage odor. However, even after treatment with microbial deodorant, calculated odor concentration and calculated odor intensity were relatively high. This is thought to be caused by other odorous substances besides H2S.

Evaluation of Odor Dispersion from Livestock Building through Field Experiment (현장실험을 통한 축산시설로부터 배출되는 축산악취의 확산 평가)

  • Yeo, Uk-Hyeon;Lee, In-Bok;Ha, Tae-Hwan;Decano, Cristina;Kim, Rack-Woo;Lee, Sang-Yeon;Kim, Jun-Gyu;Choi, Young-Bae;Park, You-Me
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.6
    • /
    • pp.21-30
    • /
    • 2019
  • Livestock odor is comprised of mixed type of odorous compounds. Among these, ammonia ($NH_3$) and hydrogen sulfide ($H_2S$) are the two known major odor causing substances. Because high odor concentration reduces productivity of livestock and causes damage to the surrounding communities, quantitative analysis is needed to manage the odor inside and outside the livestock facilities. It is also necessary to evaluate odor dispersion according to the distance between the receptors taking into account the influence of odor source and weather condition. Therefore, in this study, we tried to evaluate the internal environment and odor dispersion from experimental pig house considering weather conditions. An experimental farm was specifically selected to eliminate the interference of odors generated by adjacent farms. $NH_3$ and complex odor were quantitatively analyzed using a gas detector and air dilution sensory method. The concentration of $NH_3$ and complex odor in pig house showed a distinct concentration difference according to the cleaning and ventilation conditions. $NH_3$ concentration and complex odor was lower than emission standard in the pig house and at the site boundary. The average $NH_3$ concentration (P1~P3) and the $NH_3$ concentration at the site boundary (S1) were strongly correlated with R=0.77. While the correlation for complex odor inside and at the site boundary had R=0.52. The correlation coefficient between $NH_3$ and the complex odor was 0.80.

Assessment of Odor Characterization and Odor Unit from Livestock Facilities by animals (축산시설의 축종별 악취물질 농도 특성과 악취도 평가)

  • Jang, Young-Kee;Jung, Bong-Jin;Kim, Jeong;Song, Ki-Bong;Kim, Ho-Jung;Yoo, Yong-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.1
    • /
    • pp.29-38
    • /
    • 2010
  • At recent the number of livestock is increased and the size of farm has changed to large facilities in Korea. So the livestock facilities have become one of major sources of odor emission. The purpose of this study is to analyze the concentration and assessment of odor unit from livestock facilities for cow, dairy, swine and poultry. The eleven odor pollutants such as $H_2S$, ($CH_3$)SH, $(CH_3)_2S$, $(CH_3)_2S_2$, $CH_3N$, $NH_3$, $(CH_3)_2N$, $(CH_3)_3N$, butyric acid, valeric acid and isovaleric acid, measured for assessment of the odor concentrations from livestock facility. As the results, it is found that the major matters of odor from livestock facilities were $NH_3$ and $H_2S$. The highest concentration of $NH_3$ is measured as 15 ppm at henhouse and $H_2S$ is measured as 858 ppb at penpig facilities. In the comparison of the average odor unit from livestocks, it is found that the highest odor unit was from swine and the lowest odor unit was from cow facility. So odor unit from swine facilities was 12 to 30 times higher than the odor unit from cow facilities.

Investigation of odor Release from Combined Sewer (합류식 하수도의 악취발생 실태 연구)

  • Gil, Kyung-Ik;Shin, Geon-Cheol;Im, Ji-Yeol
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.185-191
    • /
    • 2010
  • This study investigates the odor from combined sewer in urban areas and major odor-causing facilities. Monitorings are conducted in specific areas that have representative characteristics. In combined sewer in urban areas, the real-time monitorings on sulfur, complex odor and specified odor are conducted. And in major odor-causing facilities, the real-time monitorings on complex odor, specified odor are conducted. Odor from combined sewer in urban area is affected by the changes on floating population and the effluent of the septic tank. Also major odor-causing facilities are largely affected by the effluent of the septic tank. The major odor-causing substances are found to be hydrogen sulfide($H_2S$) and methyl mercaptan. To reduce the odor from combined sewer, improvement of effluent from the septic tank and reduction of sulfur compounds have to be done.

Odor Classification and Source Analysis using Pseudo Inverse (Pseudo Inverse를 이용한 악취분류와 악취원 분석)

  • Yu, Suk-Hyun;Park, Sang-Jin;Koo, Youn-Seo;Kwon, Hee-Yong
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.8
    • /
    • pp.1171-1182
    • /
    • 2010
  • In this paper, odor classification and source analysis methods are proposed to trace odor sources in th air at the specific place and period. It is necessary to generate representative patterns in order to classify the various odors efficiently. We, therefore, create 67 kinds of odor representative patterns measured from the main sources. considering the air mixed with various odors, several mixed representative patterns for odor sources are generated with the combination of two or three different odors. In addition, the weight of odor sources for an odor from a civil complaint region are computed using pseudo inverse method. As a result, we can trace and identify the odor sources to lead to a specific odor and the contribution of each source. The results of this study will be useful for settling the civil complaint related with odors.

Estimation of Odor Emissions from Industrial Sources and Their Impact on Residential Areas using the AERMOD Dispersion Model (AERMOD 모델을 이용한 산단 지역 악취 배출량 및 주거지역 영향 범위 평가)

  • Jeong, Sang-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.87-96
    • /
    • 2011
  • In this study, the AERMOD dispersion model was used for predicting odor concentrations and back-calculating industrial area source odor emission rate. The studied area was Sihwa industrial complex in Korea. Odor samples were collected during two days over a year period in 2009. The comparison between the predicted and observed concentrations indicates that the AERMOD model could fairly well predict average downwind odor concentrations. The results show odor emission rates of Sihwa industrial complex area source were ranged from 0.204 to 2.320 $OUms^{-1}$ (average 0.476 $OUms^{-1}$). The results also show wind speed and direction are important parameters to the odor dispersion.

CALPUFF and AERMOD Dispersion Models for Estimating Odor Emissions from Industrial Complex Area Sources

  • Jeong, Sang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This study assesses the dispersion and emission rates of odor form industrial area source. CALPUFF and AERMOD Gaussian models were used for predicting downwind odor concentration and calculating odor emission rates. The studied region was Seobu industrial complex in Korea. Odor samples were collected five days over a year period in 2006. In-site meteorological data (wind direction and wind speed) were used to predict concentration. The BOOT statistical examination software was used to analyze the data. Comparison between the predicted and field sampled downwind concentration using BOOT analysis indicates that the CALPUFF model prediction is a little better than AERMOD prediction for average downwind odor concentrations. Predicted concentrations of AERMOD model have a little larger scatter than that of CALPUFF model. The results also show odor emission rates of Seobu industrial complex area were an order of 10 smaller than that of beef cattle feed lots.

Utilization of Masking Techniques to Ameliorate Agricultural Odorants

  • Yoon, Young-Mo;Schilling, Mark W.;Bazemore, Russell
    • Food Science and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.689-693
    • /
    • 2005
  • Different masking materials were evaluated for their ability to ameliorate odor of model poultry manure solution by assessing their effects on sensory pleasantness and odor intensity. Results indicated extracts from Eastern red cedar leaves, Loblolly pine needles', and commercial masking agents such as pine extract and odor neutralizer were effective (p<0.05) for masking odor of model poultry manure solution by increasing (p<0.05) pleasantness (82 and 86% increases in pleasantness using red cedar and pine needle extracts, respectively) and decreasing (p<0.05) odor intensity (odor intensity reduction by 66 and 76% using red cedar pine needle extract). The most odor-active compound in Loblolly pine needle extract was ${\alpha}$-terpineol (1,573.8 ug/g) which is responsible for aroma of pine trees (piney) and effective for ameliorating agricultural odors.

Masking Effect of Chlorine on Algae-related Taste and Odor in Drinking Water Supplies (염소의 상수원 내 조류 이취미 Masking 효과)

  • Kim, Young-il;Lee, Yu-Jeong;Shin, Heung-Sup;Bae, Byung-Uk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.2
    • /
    • pp.227-232
    • /
    • 2008
  • The masking effect of chlorine on algae-related taste and odor(T&O) compounds has long been an important issue for water suppliers. In this study, masking experiments with chlorine were performed on two kinds of treated water and one of raw water. After adding chlorine(0 to 0.8 mg/L) to water samples, odor intensity was evaluated by a newly developed sensory method(2-out-of-5 odor test) for three days along with the measurement of residual chlorine concentration. Even though the relationship between the residual chlorine concentration and odor reported by the sensory analysts was not always coincident, it was proved that residual chlorine more than a certain concentration could completely mask both added geosmin and naturally occurring T&O compounds. For the sand-filtered water spiked with 10 ng/L of geosmin, 0.12-0.18 mg/L of residual chlorine was necessary to achieve complete masking. In the case of GAC-filtered water, 10 ng/L of spiked geosmin was completely masked by 0.15-0.1 mg/L of residual chlorine. Combined ozone and GAC was not enough to treat raw water spiked with 300 ng/L of geosmin. In this experiment, sensory analysts were able to detect earthy or musty odors from the treated water. From a masking experiment with raw water taken from the Daechung Reservoir, it was found that fishy odor was more difficult to mask with chlorine than earthy odor. As the chlorine residual declined, the analysts began to notice the original odor and the fishy odor was noticed earlier than the earthy odor.

A Study on the Odor Compounds Emitted using Odor Contribution Analysis - Focus on the Ochang Scientific Industrial Complex Area - (악취기여도평가를 이용한 악취원인물질 연구 - 오창과학산업단지를 중심으로 -)

  • Jung, Ji-Sun;Kim, Duk-Chul;Lee, Han-Chul;Yeon, Seoung-Won;Yeon, Ik-Jun
    • Journal of Environmental Science International
    • /
    • v.25 no.9
    • /
    • pp.1329-1339
    • /
    • 2016
  • The purpose of this study was to obtain the basic data needed to identify the impact of the odor, emitted from the Ochang Scientific Industrial Complex area on the surrounding residential areas by measuring and confirming odor compounds. The analysis showed that complex odors were diluted from around 4 to 1. The offensive odor measurement results showed that among the sites, site 1 was highest in sulfur compounds, site 2 was highest in toluene, site 3 was highest in trimethylamine, and site 4 was highest in buthylaldehyde. It cannot be decided to be odor-causing compounds for higher odor concentration because each odor substance has a different odor threshold value. According to the odor contribution analysis for each site, site 1, site 2, and site 4 contained high buthylaldehyde concentrations, and site 3 had a high level of trimethylamine. It could be determined that highly evaluated substances were main causes to result in substance for each site.