• Title/Summary/Keyword: objective mirror

Search Result 61, Processing Time 0.024 seconds

A Single Lens Micro-Angle Sensor

  • Saito, Yusuke;Gao, Wei;Kiyono, Satoshi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.14-19
    • /
    • 2007
  • Angle sensors based on the principle of autocollimation, which are usually called autocollimators, can accurately measure small tilt angles of a light-reflecting flat surface. This paper describes a prototype micro-angle sensor that is based on the laser autocollimation technique. The new angle sensor is compact and consists of a laser diode as the light source and a quadrant photodiode as a position-sensing device. Because of its concise design, the microangle sensor facilitates dynamic measurements of the angular error motions of a precision stage without influencing the original dynamic properties of the stage. This is because the sensor only requires a small extra target mirror to be mounted on the stage. The sensitivity of the angle detection is independent of the focal length of the objective lens; therefore, an objective lens with a relatively short focal length is employed to reduce the size of the device. The micro-angle sensor uses a single lens for the both the laser collimation and focusing, which distinguishes it from the conventional laser autocollimation method that has separate collimate and objective lenses. The new micro-angle sensor has dimensions of $15.1\times22.0\times14.0mm$ and its resolution is better than 0.1 arc-second The optical design and performance of this micro-angle sensor were verified by experimental results.

Development of the 4th Generation CD Optical Pick-up with Small Thickness (4세대 박형 CD 광학 픽업 개발)

  • 최영석;김성근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.3
    • /
    • pp.38-49
    • /
    • 1998
  • The 3rd generation optical pick-up used popularly in resent years is composed of many optical and electronic components such as laser diode, photo diode, beam splitter, objective lens, grating lens, concave lens, collimator lens etc. Therefore, the design of its optical system and its main base which the said optical and electronic components are set on, is complicated and needs high precision. Its assembly and adjustment in the production line is also difficult. This complication and the demand of high precision get its production cost to be high and its reliability to be low. In this paper, the 4th generation optical pick-up is designed and developed, with the hologram device which laser diode. photo diode, beam splitter. and grating lens are integrated in. This optical pick-up reduces the number of points of adjustment by 3, compared with the 3rd generation optical pick-up of which the number of points of adjustment is 6. This optical pickup also decreases by 4 the number of points of W bonding to have bad influence on environmental reliability, decreases by about 10 the number of parts, and establishes about 20% cost-down of material cost, compared with the 3rd generation optical pick-up.

  • PDF

The Study of Micro Fabrication using Picosecond Laser Ablation (피코초 레이저 어블레이션을 이용한 미세 가공 연구)

  • Noh, Ji-Whan;Sohn, Hyon-Kee;Suh, Jeong;Lee, Jae-Hoon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.2
    • /
    • pp.25-28
    • /
    • 2010
  • The micro fabrication on the mold material using picosecond laser ablation processing has been studied. We used the two kind of system with picosecond laser. First one is two mirror type scanner and telecentric f-theta lens. Second one is X-Y stage and objective lens. By using these system, the $100{\mu}m$ size chess patterning and $2{\mu}m$ size patterning was fabricated. Especially $2{\mu}m$ size patterning on the mold material can be used as the decorative rainbow color logo for industrial field. In this paper, it is proved the picosecond laser is effective tool for the laser ablation processing.

Measurements of Dynamic Response of Micro-Mirror using Position Sensitive Detector (PSD를 이용한 MMAD의 동작특성 측정에 관한 연구)

  • Kim, Jong-Kook;Kim, Ho-Seong;Shin, Hyung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2527-2529
    • /
    • 1998
  • Measurement equipment, which consists of He-Ne laser, objective lens, CCD camera and position sensitive detector, was developed for the dynamic response of micromirror. This equipment can measure the tilting direction and angle, the rise time and frequency response of micromirror to the input signal. It was found that the rise time of the micromirror was less than 10${\mu}m$ and the resonant frequency was about 25kHz.

  • PDF

The Flame Characteristics of Annular Combustor for Gas Turbine according to Combustor Length Ratio (가스터빈용 환형연소기의 연소실 길이비에 따른 화염특성)

  • Kim, Jaeyeong;Lee, Dongwon;Lee, Keeman
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.127-130
    • /
    • 2015
  • The objective of this study is to investigate the real flame shape and characteristic of annular combustor. To identify the effects of combustor length ratio and equivalence ratio on the flame shape in annular combustion configuration, the employed parameters are combustor length ratio 0.6-1.0, equivalence ratio 0.7-1.1. The flame shape is visualized using DSLR camera and precision optic mirror. The flame intensity is analyzed by $OH^{*}$ chemiluminescence images with ICCD camera. CO and NOx emission performance is also examined using an exhaust gas analyzer. From the visualized images, it is confirmed that the different tendency appeared in combustor length ratio 0.6-0.7 and 0.8-1.0. The results of $OH^{*}$ chemiluminescence show that the flame intensity is the most uniform for equivalence ratio 0.9. The smaller equivalence ratio is, the less emission of CO and NOx will be in this investigation range.

  • PDF

The Development of a Tongue Diagnosis System and the Evaluation of Reproducibility (설진 시스템 개발 및 재현성 평가)

  • Jeon, Young-Ju;Kim, Keun-Ho;Do, Jun-Hyeong;Ryu, Hyun-Hee;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.97-102
    • /
    • 2008
  • The tongue diagnosis is a diagnostic method in the oriental medicine that uses shape, substance, coating, and movement of the tongue to determine the condition of health and disease characteristics in human. Since this information, however, could be affected by subjective sense and visual information, it is difficult to obtain the objective and reproducible results. This research aims at building a reproducible tongue diagnosis system using color chart that is attached close to the face contact region. The picture of color chart is taken simultaneously with a tongue and applied to color revision. The system, in addition, is focused on providing a clear tongue image through securing a sufficient photographing distance with a surface coating mirror. The lightning part which can suppress the reflection by sputum in maximum is implemented for the objectification and quantification of the tongue diagnosis system. The face contact region is designed for consideration of a testee's convenience. To evaluate the reproducibility of the system, the CVs (coefficient of variance, %) of $L{\ast}$, $a{\ast}$ and $b{\ast}$ of red, green and blue regions in color chart are calculated, respectively. The results of all CVs shows that the tongue diagnosis system is re liable and those consequences contribute to the objectification and quantification of the tongue diagnosis system.

  • PDF

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Phase-shifting diffraction grating interferometer for testing concave mirrors (오목 거울 측정용 위상천이 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.392-398
    • /
    • 2003
  • We present a novel concept of a phase-shifting diffraction-grating interferometer, which is intended for the optical testing of concave mirrors with high precision. The interferometer is configured with a single reflective diffraction grating, which performs multiple functions of beam splitting, beam recombination, and phase shifting. The reference and test wave fronts are generated by means of reflective diffraction at the focal plane of a microscope objective with large numerical aperture, which allows testing fast mirrors with low f-numbers. The fiber-optic confocal design is adopted for the microscope objective to focus a converging beam on the diffractive grating, which greatly reduces the alignment error between the focusing optics and the diffraction grating. Translating the grating provides phase shifting, which allows measurement of the figure errors of the test mirror to nanometer accuracy.

WIDEBAND SPECTRAL DISPERSER MADE OF ZnS FOR EXOPLANET CHARACTERIZATION USING SPACE-BORNE TELESCOPES

  • Enya, Keigo;Fujishiro, Naofumi
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.343-345
    • /
    • 2017
  • We present the development of a spectral dispersion device for wideband spectroscopy for which the primary scientific objective is the characterization of transiting exoplanets. The principle of the disperser is simple: a grating is fabricated on the surface of a prism. The direction of the spectral dispersion power of the prism is crossed with the grating. Thus, the prism separates the spectrum into individual orders while the grating produces a spectrum for each order. In this work, ZnS was selected as the material for the cross disperser, which was designed to cover the wavelength region, ${\lambda}=0.6-13{\mu}m$, with a spectral resolving power, $R{\geq}50$. A disperser was fabricated, and an evaluation of its surface was conducted. Two spectrometer designs, one adopting ZnS (${\lambda}=0.6-13{\mu}m$, $R{\geq}300$) and the other adopting CdZnTe (${\lambda}=1-23{\mu}m$, $R{\geq}250$), are presented. The spectrometers, each of which has no moving mechanical parts, consist simply of a disperser, a focusing mirror, and a detector.

Measurement of Micro Thermal Deformation of Optical Pick-up Base Using Holographic Interferometry (흘로그램 간섭계를 이용한 광픽업 베이스의 미소 열변형 측정)

  • 서영민;강신일
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.191-194
    • /
    • 2002
  • In optical pick-up, optical components such as objective lens, collimator, mirror, laser diode and photo diode are mounted on the pick-up base. These components must keep their original position during operation for proper transmittance of information from laser diode to optical disk and back to photo diode. However, micro thermal deformation of pick-up base which is induced by thermal environment during operation can deteriorate the performance of optical pick-up. Therefore, it is important to measure and analyze the thermal deformation behavior of pick-up base under thermal environment. In the present study, a measurement system using holographic interferometry was designed to measure micro thermal deformation of pick up base. The measurement system was verified by using the deformation of cantilever with prescribed motion actuated by PZT with 1 nm resolution. Interferometric measurement was compared quantitatively with that induced by PZT actuator. Finally, micro thermal deformation of pick-up base under actual thermal environment was measured using the present holographic interferometry and the results were analysed.

  • PDF