• Title/Summary/Keyword: numerical calculations

Search Result 1,106, Processing Time 0.027 seconds

Numerical Analyses of Performance and Combustion in KSR-III Liquid Propellant Rocket Engine with Combustion Stabilization Device (연소 안정성 기구를 장착한 KSR-III 액체로켓 엔진의 성능 및 연소 해석)

  • Moon, Yoon-Wan
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.41-50
    • /
    • 2003
  • Numerical analysis was carried out to investigate performance and combustion characteristics of KSR-III liquid rocket engine with several types of baffle. To evaluate the change of performance and combustion characteristics with several types of baffle, the first numerical calculations were performed about baffle tab, radial blade baffle, and hub-and-spoke baffle. Then radial blade and hub-and-spoke baffle were determined to design two types of the KSR-III engine with baffles. Also to investigate the effect of injector arrangements and baffle positions, two types of radial blade baffle were calculated then numerical calculations were carried out with changing axial length of radial blade I, II and hub-and-spoke baffle. While axial length of baffle effected to performance very small, injector arrangement effected to performance largely through calculations of radial blade I, II. From the viewpoint of combustion instability, hub-and-spoke baffle controlled combustion instability effectively and there was the performance of hub-and-spoke baffle between radial blade I and II.

  • PDF

Heat Transfer Study to Replace a Tube Bundle of Moisture Separator Reheater at Nuclear Power Plant (원전 습분분리재열기 튜브 번들 교체를 위한 열전달 고찰)

  • Choi, You-Sung;Choi, Kwang-Hee;Lee, Sang-Guk
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.65-71
    • /
    • 2010
  • The plugging rate of reheater tubes of Wolsung unit 1 nuclear power plant has been increased by corrosion and erosion since 1990. As the dimensions of the new first stage reheater bundle tubes which were supplied by Hanjung company to replace were different from old one, numerical calculations are carried out for flow and heat transfer in the reheater bundle tubes of the N.P.P. Numerical calculations consists of thermal performance, drain line pressure drop, flow change by pressure drop of line, stress analysis of finned tubes and analysis of flow induced vibration. Computational analysis using heat transfer research institute program is adopted to verify the results of the numerical calculations. It contains the evalution of performance in the system with view to location of the new reheater bundle and it shows the differences between the numerical calculation results and heat transfer research institute program output.

  • PDF

The Effect of The Drift Velocity on The Ship Motion (표류(漂流)를 고려한 선체운동(船體運動))

  • J.H.,Hwang;Y.J.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.18 no.3
    • /
    • pp.29-38
    • /
    • 1981
  • In general the drift result in ship heeling, thus it seems to be necessary to analyze the ship motion by considering both the drifting and heeling phenomena. In this paper, a drift velocity and a heeling angle are given as prior conditions, and then within the linear potential theory the hydrodynamic coefficients and wave exciting forces and moments are derived for a ship advancing and drifting with constant speeds. And numerical calculations are preformed for a cylindrical body of shiplike cross section at zerp forward velocity. The 2-D hydrodynamic forces and moments of a heeled cylinder are calculated by using the Frank Close-Fit method. These numerical results for the oscillating cylinder without drift velocity have shown better agreements with experimental data than the numerical results of Kobayashi[2]. The motion responses for a drifting cylinder are calculated ignoring the drift velocity effect in the free surface condition. The accuracy of these calculations can not be verified, because the experimental data are not available. Through these numerical calculations to so concluded that drift velocity effects on the body motion are signiffcant.

  • PDF

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.193-201
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.

Leakage Flow Influence on SHF pump model performances

  • Dupont, Patrick;Bayeul-Laine, Annie-Claude;Dazin, Antoine;Bois, Gerard;Roussette, Olivier;Si, Qiaorui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.4
    • /
    • pp.274-282
    • /
    • 2015
  • This paper deals with the influence of leakage flow existing in SHF pump model on the analysis of internal flow behaviour inside the vane diffuser of the pump model performance using both experiments and calculations. PIV measurements have been performed at different hub to shroud planes inside one diffuser channel passage for a given speed of rotation and various flow rates. For each operating condition, the PIV measurements have been trigged with different angular impeller positions. The performances and the static pressure rise of the diffuser were also measured using a three-hole probe. The numerical simulations were carried out with Star CCM+ 9.06 code (RANS frozen and unsteady calculations). Some results were already presented at the XXth IAHR Symposium for three flowrates for RANS frozen and URANS calculations. In the present paper, comparisons between URANS calculations with and without leakages and experimental results are presented and discussed for these flow rates. The performances of the diffuser obtained by numerical calculations are compared to those obtained by the three-holes probe measurements. The comparisons show the influence of fluid leakages on global performances and a real improvement concerning the efficiency of the diffuser, the pump and the velocity distributions. These results show that leakage is an important parameter that has to be taken into account in order to make improved comparisons between numerical approaches and experiments in such a specific model set up.

Numerical Study of Film Cooling Characteristics in Turbine Blade Cavity (터빈 블레이드 캐버티 내 막냉각 특성에 관한 수치해석적 연구)

  • Kim, Kyung-Seok;Cho, Hyung-Hee;Kang, Shin-Hyoung
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.648-651
    • /
    • 2008
  • Numerical calculations are performed to simulate the film cooling effect of turbine blade tip with squealer rim. Because of high temperature of inside rim, squealer rim is damaged easily. Therefore many various cooling systems were used. The calculations are based on 100,000 Reynolds number in linear cascade model. A blade has 2% tip clearance and 8.4% rim height. The axial chord length and turning angle is 237mm, 126$^{\circ}$. Numerical calculations are performed without and with film cooling. In a film cooling in the cavity, hot spots of cavity were cooled effectively. However hot spots of suction side rim still remains. The CFD results show that the circulation flow in cavity of squealer tip affects the temperature rise of squealer rim. To maintain the blade integrity and avoid the excessive hot spot of blade, rearrangement of cooling hole is needed.

  • PDF

Numerical Analysis of Swirling Turbulent Flow in a Pipe (원관내 난류 선회류의 수치해석)

  • Lee, D.W.;Kim, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.3
    • /
    • pp.396-405
    • /
    • 1995
  • Numerical calculations are carried out for the swirling turbulent flow in a pipe. Calculations are made for the flow with swirl parameter of 2.25 and the Reynolds number of 24,300. The turbulence closure models used in these calculations are two different types of Reynolds stress model, and the results are compared with those of $k-{\varepsilon}$ model and the experimental data. The finite volume method is used for the discretization, and the power-law scheme is employed as a numerical scheme. The SIMPLE algorithm is used for velocity-pressure correction. The computational results show that GL model gives the results better than those of SSG model in the predictions of velocity and stress components.

  • PDF

Graphical Study on the Entropy of Order Statistics

  • Park, Sang-Un
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.2
    • /
    • pp.307-313
    • /
    • 1998
  • The entropy measure is considered to denote the uncertainty of order statistics filters and choose the length of consecutive order statistic filters. However, it needs much calculations to get the amount of the entropy of all possible sets of consecutive order statistics, and the results of those calculations return many numerical values. Thus we provide an efficient graphical presentation of those numerical values, which make it easy to understand the distribution of the entropy among order statistics.

  • PDF

Viscous Flow Analysis of the Waterjet Duct (물분사 추진기 관내 점성유동해석)

  • 왕정용;전호환;박일룡;차상명
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.10a
    • /
    • pp.68-72
    • /
    • 2000
  • In the present paper, the numerical calculations for the viscous duct flow of water jet propulsion systems ship are carried out. The governing equation, incompressible Navier-Stokes equation, is discretized and analysed by a Method with the stcandard turbulence modeling. For the calculations the duct flow which h e intake flows disturbed by the ship, the results dcuhted by the potenti used Numerical results show fairly good agreement with the experimental data

  • PDF

Collapse of Magnetised, Singular Isothermal Toroids

  • ALLEN ANTHONY;SHU FRANK;LI ZHI- YUN
    • Journal of The Korean Astronomical Society
    • /
    • v.34 no.4
    • /
    • pp.325-327
    • /
    • 2001
  • This poster summarizes numerical collapse calculations of non-rotating and rotating singular, isothermal toroids that employed the zeus2d (Norman and Stone 1992) magnetohydrodynamics package. In the non-rotating collapse calculations, it is seen that infall proceeds at a constant rate and magnetically supported, high density pseudo-disks form in the equatorial plane. With rotating clouds, however, toroidal magnetic fields grow as infall proceeds, teaming with angular momentum to slow the inflow to the center and generate outflow.