• Title/Summary/Keyword: numerical aperture

Search Result 192, Processing Time 0.022 seconds

Nanocomposite Cover-layer for NFR Media (Nanocomposite 이용한 NFR Media 커버층 특성연구)

  • Kim, Jin-Hong;Lee, Jun-Seok;Seo, Jeong-Kyo
    • Transactions of the Society of Information Storage Systems
    • /
    • v.3 no.1
    • /
    • pp.17-22
    • /
    • 2007
  • [ $TiO_2$ ] nanoparticles are added into UV curable resin to increase the refractive index of the cover-layer which is laminated on the media for cover-layer incident NFR. High refractive index is required for the cover-layer operating for the solid immersion lens optics with high effective numerical aperture. The eyepattern could be achieved from the cover-layer coated 20 GB ROM disc in which the refractive index of the cover-layer was 1.75, but the gap servo was unstable due to the rough surface of the cover-layer. Even though the light loss due to the nanoparticles is not serious, the rough microstructure is developed by adding the nanoparticles in the organic binder material. To achieve smooth surface for the stable gap servo, some special techniques should be added, for example the solubility of the nanoparticles should be enhanced by the optimization of the surface of the nanoparticles.

  • PDF

Design And Optimization Of Actuator For Micro Optical Disk Drive Using Response Surface Methodology (반응표면법을 이용한 초소형 광디스크 드라이브 구동기의 최적화 및 디자인)

  • 우기석;이동주;박노철;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.755-761
    • /
    • 2003
  • Recently, the development of mobile devices demands information storage systems to use micro drive devices and cheap media. These should have several characteristics, for example, the subminiature of size, the robustness of shock, the minimum of cost and power consumption, and the removability of multiple applications. A conventional optical disk drive is more suitable for these specifications than the others. The optical storage system of the new generation to use a blue laser and a high numerical aperture (NA) is the perfect candidate for micro optical disk drives. In this paper, the micro actuator that can be applied to a micro optical disk drive is designed by response surface methodology to use a structural analysis and an electro-magnetic analysis. Based on above results, the coarse actuator and fine actuator are designed and improved from the point of view of the size and the power. Consequently, the designs of a micro actuator are proposed through these courses.

  • PDF

Design and Aberration Analysis of Four-Spherical Mirror System Corrected for 4 Aberrations (4개의 수차가 보정된 유한 물체점을 갖는 4-구면 반사경계의 설계 및 수차해석)

  • 김종태;공홍진;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.127-132
    • /
    • 1991
  • We have obtained the analytic solutions of the four spherical mirror system free from the Seidel third order aberratios which are spherical aberration, coma, astigmatism, and distortion, Vignetting. Petzval field curvature, and optical properties according to the design parameters are numerically investigated and optimized. The numerical aperture of this system is 0.2 and the half field angle is $1.5^{\circ}$.

  • PDF

Utilization of Light Microscopy and FFT for MFA Measurement from Unstained Sections of Red Pine (Pinus Densiflora)

  • Kwon, Ohkyung;Lee, Mi-Rim;Eom, Chang-Deuk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.399-405
    • /
    • 2013
  • This study demonstrates the utilization of light microscopy and Fast Fourier Transform-Peak Finding (FPF) method for microfibril angle (MFA) measurement from unstained sections of red pine (Pinus densiflora). To obtain an image with optimal contrast and resolution for MFA measurement, effects of numerical aperture (NA) of condenser lens and color filters were investigated. About 60% of NA of the maximum condenser NA produced an image with optimal contrast, but a color filter with short wavelength range (DAPI) created images with improved resolution. Manual angle measurement and the FPF method were applied to the image with optimal contrast for MFA measurement. The experimental results from the FPF method were considered to be more repeatable and less subjective than those from the manual angle measurement.

Theoretical analysis of optimum refractive index profile and maximum transmission length of a GIPOF (GIPOF의 최적 굴절률 분포와 최대 전송거리에 대한 연구)

  • Jeong Hun;Kim Seung Taek;Gang Seong Bok;Lee Gyeong Gyun;Gang Hui Seok;Jo Yeong Jun
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.14-15
    • /
    • 2003
  • Polymer optical fibers (POFs) are being considered as important high-speed communication media in the area of local area networks, datalinks and optical sensors. Large core diameter (500~1000 $\mu$m) and large numerical aperture (0.2~0.9) in a POF allow easy processing and connectorization, low cost high efficiency of beam coupling from LDs or LEDs, and complete immunity to EMI/EMR. There are many reports about 2.5 Gbps transmission the polymethylmethacrylate (PMMA) graded index (GI) POF over a distance of 100 m. (omitted)

  • PDF

Solid Immersion Lens Microscope for Spectroscopy of Nanostructure Materials

  • Yim, Sang-Youp;Kim, Joon-Heon;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.78-81
    • /
    • 2011
  • We demonstrate a high-spatial-resolution imaging and spectroscopy tool using a solid immersion lens (SIL), a hemispherical lens made of high refractive index glass (n ~2). Photoluminescence (PL) images of single CdSe nanocrystals confirm a numerical aperture enhancement factor of ~2, close to the refractive index of the SIL. In particular, a bare-eye observation of PL signals emitted by single nanocrystals with ${\sim}10\;{\mu}m^{-2}$ densities was possible over an ${\sim}30\;{\mu}m$ diameter region. In addition, the PL spectra of single CdSe nanocrystals were successfully measured at room temperature. Thus, this SIL microscope ensures a simple but powerful method for nanostructure spectroscopy.

Nonparaxial Imaging Theory for Differential Phase Contrast Imaging

  • Jeongmin Kim
    • Current Optics and Photonics
    • /
    • v.7 no.5
    • /
    • pp.537-544
    • /
    • 2023
  • Differential phase contrast (DPC) microscopy, a central quantitative phase imaging (QPI) technique in cell biology, facilitates label-free, real-time monitoring of intrinsic optical phase variations in biological samples. The existing DPC imaging theory, while important for QPI, is grounded in paraxial diffraction theory. However, this theory lacks accuracy when applied to high numerical aperture (NA) systems that are vital for high-resolution cellular studies. To tackle this limitation, we have, for the first time, formulated a nonparaxial DPC imaging equation with a transmission cross-coefficient (TCC) for high NA DPC microscopy. Our theoretical framework incorporates the apodization of the high NA objective lens, nonparaxial light propagation, and the angular distribution of source intensity or detector sensitivity. Thus, our TCC model deviates significantly from traditional paraxial TCCs, influenced by both NA and the angular variation of illumination or detection. Our nonparaxial imaging theory could enhance phase retrieval accuracy in QPI based on high NA DPC imaging.

Application of the Homogenization Analysis to Calculation of a Permeability Coefficient (투수계수 산정을 위한 균질화 해석법의 적응)

  • 채병곤
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.79-86
    • /
    • 2004
  • Hydraulic conductivity along rock fracture is mainly dependent on fracture geometries such as orientation, aperture, roughness and connectivity. Therefore, it needs to consider fracture geometries sufficiently on a fracture model for a numerical analysis to calculate permeability coefficient in a fracture. This study performed new type of numerical analysis using a homogenization analysis method to calculate permeability coefficient accurately along single fractures with several fracture models that were considered fracture geometries as much as possible. First of all, fracture roughness and aperture variation due to normal stress applied on a fracture were directly measured under a confocal laser scaning microscope (CLSM). The acquired geometric data were used as input data to construct fracture models for the homogenization analysis (HA). Using the constructed fracture models, the homogenization analysis method can compute permeability coefficient with consideration of material properties both in microscale and in macroscale. The HA is a new type of perturbation theory developed to characterize the behavior of a micro inhomogeneous material with a periodic microstructure. It calculates micro scale permeability coefficient at homogeneous microscale, and then, computes a homogenized permeability coefficient (C-permeability coefficient) at macro scale. Therefore, it is possible to analyze accurate characteristics of permeability reflected with local effect of facture geometry. Several computations of the HA were conducted to prove validity of the HA results compared with the empirical equations of permeability in the previous studies using the constructed 2-D fracture models. The model can be classified into a parallel plate model that has fracture roughness and identical aperture along a fracture. According to the computation results, the conventional C-permeability coefficients have values in the range of the same order or difference of one order from the permeability coefficients calculated by an empirical equation. It means that the HA result is valid to calculate permeability coefficient along a fracture. However, it should be noted that C-permeability coefficient is more accurate result than the preexisting equations of permeability calculation, because the HA considers permeability characteristics of locally inhomogeneous fracture geometries and material properties both in microscale and macroscale.

Influence of Design Parameters of Grout Injection in Rock Mass using Numerical Analysis (암반 그라우팅 주입 설계변수가 주입성능에 미치는 영향의 수치해석적 평가)

  • Lee, Jong Won;Kim, Hyung Mok;Yazdani, Mahmoud;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.27 no.5
    • /
    • pp.324-332
    • /
    • 2017
  • In this paper, a numerical analysis of one-dimensional viscous fluid flow in a rock joint using UDEC code is performed to evaluate the effect of design parameters on injection performance. We consider injection pressure, fluid compressibility, time dependence of yield strength and viscosity of injected grout fluid, and mechanical deformation of joint as the design parameters, and penetration length and flow rate of injection are investigated as the injection performance. Numerical estimations of penetration length and flow rate were compared to analytical solution and were well comparable with each other. We showed that cumulative injection volume can be over-estimated by 1.2 times than the case that the time-dependent viscosity evolution is not considered. We also carried out a coupled fluid flow and mechanical deformation analysis and demonstrated that injection-induced joint opening may result in the increment of cumulative volume by 4.4 times of that from the flow only analysis in which joint aperture is kept constant.

Interference Fringe Signal Filtering Method for Performance Enhancing of White Light Interfrometry (가간섭 영역 외의 배경 잡음성 간섭무늬 신호 필터링을 통한 백색광 주사간섭계의 성능 향상)

  • Yim, Hae-Dong;Lee, Min-Woo;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.272-275
    • /
    • 2009
  • In order to enhance the background noise filtering performance of the white light interferometry(WLI), we demonstrate the noise filtering performance of preprocessing of the measured fringe signals. The WLI was realized through a mirau interferometer which was equipped with a green LED. When measuring large-height and rough surface objects, the illumination optics are considered the numerical aperture(NA) and the depth of focus(DOF). In this case, the limited NA of the illumination optics has a considerable impact on the interference fringe. Therefore, we propose a preprocessing method that uses the intensity difference between the measured intensity and the moving average intensity. The performance is demonstrated by measuring an array of metal solder balls fabricated on printed circuit board(PCB). The proposed method reduces the noise pixels by 15 percent.