• Title/Summary/Keyword: normal insulation material

Search Result 37, Processing Time 0.026 seconds

Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen (액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성)

  • Lee, Sang-Hwa;Shin, Woo-Ju;Khan, Umer Amir;Oh, Seok-Ho;Sung, Jae-Kyu;Lee, Bang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

Experimental Study on Fire Resistant Capacity and Thermal Conduction of Construction Material Using the Circulation Resources (폐콘크리트 순환자원을 이용한 건설재료의 화재내력 및 단열성에 관한 실험적 연구)

  • Choi, Jea-Nam;Hong, Se-Hwa;Son, Ki-Sang
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.3
    • /
    • pp.121-128
    • /
    • 2010
  • This is to show some basic data for introducing both circulated aggregate and recycled powder producing waste concrete. Standard-mixing design for 24MPa has been basically used and added and replaced normal aggregate with recycled powder made of waste concrete. In addition, polycarboxylate high-range water reducing agent has been used because recycled powder is missing adhesive strength and it is not compare with cement's adhesive strength. Compressive strength with powder mixture of 2%, 4%, 6%, 8%, and 10% has been decreased down to 80% of normal concrete material strength without recycled powder mixture. $200^{\circ}C$, $400^{\circ}C$ and $600^{\circ}C$ heated concrete were compressively tested in order to find out concrete strength resistant to high temperature. heat capacity was also tested, based on the expectancy of its low conductivity. In addition, thermal conduction test was tested in order to find out concrete insulation. According to this test, when concrete was tested by fire resistance, it using the circulation aggregate was same resulted by concrete using the natural aggregate. also, recycle powder was not effecting insulation performance. but it is fit to standard on concrete insulation of building law.

The Properties of Concrete with Lightweight Aggregate Impregnated by Phase Change Material (상변화물질 함침 경량골재를 사용한 콘크리트의 특성)

  • Kim, Se-Hwan;Jeon, Hyun-Kyu;Hwang, In-Dong;Seo, Chee-Ho;Kim, Sang-Heon
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.331-338
    • /
    • 2013
  • Under the paradigm of sustainable green growth at the national level, various researches and applications for energy saving in the construction field has been attempted. As a part of energy saving efforts, lightweight concrete was investigated for thermal insulation concrete with phase change material (PCM) which has high heat storage capacity. As a part of energy saving efforts, thermal insulation concrete was investigated and evaluated with lightweight aggregate impregnated by PCM which has high heat storage capacity. As a result, it is found that concrete with lightweight aggregate impregnated by PCM is effective to prevent its quality deterioration by reducing water absorption rate of lightweight aggregate. In addition, it has shown that concretes using lightweight aggregate and impregnated lightweight aggregate improve heat insulation property 33% and 40~43% compared with using normal aggregate, respectively. It is that the lightweight aggregate concrete with impregnated lightweight aggregate has 12~14% lower thermal conductivity than unimpregnated.

Classification of stator coil degradation of traction motor by PD signal distribution analysis (PD 분포 분석에 의한 견인전동기 고정자 코일의 열화도 분류에 관한 연구)

  • Park, Seong-Hee;Lim, Jong-Ho;Jang, Dong-Uk;Park, Hyun-June;Kang, Seong-Hwa;Lim, Kee-Joe
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1183-1186
    • /
    • 2004
  • Degradation and insulation failure of traction motor depend on the continuous stress imposed on it. And knowing on insulation condition is important thing for safety operation of EMU(electric multiple unit). In this paper, PD(partial discharge) characteristics for degradation analysis of stator coil is studied. For PD data acquisition, two models are made; one is normal condition coil, the other is aged condition coil. And PD data for discrimination were acquired from PD detector. And these data making use of a computer-aided discharge analyser, statistical and other discharge parameters is calculated to discrimination between different discharge sources. And also these parameter is applied to classify PD sources by neural networks. Neural Networks has good recognition rate for degradation of stator coil.

  • PDF

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Study on Resistance Increasement Tendency and Recovery Characteristics of YBCO Thin-film Wire Using Insulation Layer (절연 층이 고려된 YBCO 박막형 선재의 저항 증가 경향 및 회복 특성에 관한 연구)

  • Du, Ho-Ik;Kim, Yong-Jin;Lee, Dong-Hyeok;Han, Byoung-Sung;Song, Sang-Seob;Lee, Jeong-Su;Han, Sang-Chul;Lee, Jung-Phil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.190-190
    • /
    • 2010
  • The resistance and recovery properties of the YBCO thin-film wire according to the existence and thickness of an insulting layer, and the kinds of stabilization layers, were analyzed at 90 K, 180 K and 250 K. In this study, YBCO thin-film wires with different stabilizing layers and with insulating layers were examined in terms of their various characteristics, such as quenching occurrence, spread, and distribution, based on their resistance increase trends and their recovery from quenching, and the results were qualitatively explained. The results of this study on the characteristics of YBCO thin-film wires' superconducting and normal-conducting phase changes are expected to be useful in designing superconducting power machines and in improving their performance.

  • PDF

A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type (하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구)

  • Choi, Chung-Seog
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

A Study on Growthing Process of Electrical Tree According to Crosslinked Temperature Variation in XLPE (가교폴리에틸렌 수지의 가교온도변화에 따른 전기트리의 진전과정에 관한 연구)

  • 김상기;김덕근;임장섭;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.173-176
    • /
    • 1999
  • Crosslinked Decree is an important 7actor to determine dielectric property of crosslinked polyethylene(XLPE) used for the insulation material in Power cables. Recently, though it is necessary to investigate electrical properties according to crosslinked degree as a Part of the whose characterization of cable. it is not examined closely. In this study. crosslinked degree of samples were measured according to temperature and holding time of crosslinking. electrical tree characteristics of these characteristics of these samples were analyzed by crosslinked degree and applied temperature that was chanced from normal temperature to operating temperature of power cables. As a result. when the crosslinked degree was low, dielectric properties were decreased and influence of temperature was increased. but the crosslinked degrees were high, initiation voltages of treeing were increased and dielectric properties were improved. It is proved that the optimum crosslinked degree was one of most important factor for aging time and residual lifetime of Power cable.

  • PDF

Partial Discharge Quality Measurement improvement of XLPE Cable of 154kV by new method of FSA (박 센서 배열에 따른 154kV XLPE 케이블의 부분방전 검출 특성 연구)

  • Shin, Dong-Hoon;Yang, Jong-Seok;Lwin, Kyaw-Soe;Lim, Jong-Cheon;Hwang, Doo-Hyun;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.158-159
    • /
    • 2006
  • The system measuring the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We included two parts in this discussion; The proposed method of Foil Sensor Array and the normally used method m the practice. Firstly, it will be shown the improved sensitivity of our proposed FSA sensor compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors such as $2{\times}2$, $2{\times}4$, $3{\times}3$ etc. using in our experiments, was shown. From the obtained results, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

  • PDF

A Study on FSA Application and Standardization for Partial Discharge Measurement of 154 kV XLPE Cable (154 kV XLPE 전력케이블의 부분방전 측정을 위한 FSA의 적용 및 표준화 연구)

  • Shin, Dong-Hoon;Lwin, Kyawsoe;Yang, Jong-Seok;Hwang, Doo-Hyun;Lim, Jong-Chun;Park, Noh-Joon;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.462-466
    • /
    • 2007
  • The measuring system of the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We will discussed this research which has included two parts. The proposed method of Foil Sensor Array(FSA) and the normally used method in the practice. Firstly, it will be shown the improved sensitivity of a FSA sensor, which is our aim, compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors was shown. According to our experiments, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.