• Title/Summary/Keyword: non-contact detection

Search Result 176, Processing Time 0.032 seconds

Development of the Inductive Proximity Sensor Module for Detection of Non-contact Vibration (비접촉 진동 검출을 위한 유도성 근접센서모듈 개발)

  • Nam, Si-Byung;Yun, Gun-Jin;Lim, Su-Il
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.5
    • /
    • pp.61-71
    • /
    • 2011
  • To measure the fatigue of metallic objects at high speed vibration while non-contact precision displacement measurement on how to have a lot of research conducted. Noncontact high-speed vibration detection sensor of the eddy current sensors and laser sensors are used, but it is very expensive. Recently, High-speed vibrations detection using an inexpensive inductive sensor to have been studied, but is still a beginner. In this paper, a new design of an inexpensive inductive proximity sensor has been suggested in order to measure high frequency dynamic displacements of metallic specimens in a noncontact manner. Detection of the existing inductive sensors, detection, integral, and amplified through a process to detect the displacement noise due to weak nature of analog circuits and integral factor in the process of displacement detection is slow. The proposed method could be less affected by noise, the analog receive and high-speed signal processing is a new way, because AD converter (Analog to Digital converter) without using the vibration frequency signals directly into digital signals are converted. In order to evaluate the sensing performance, The proposed sensor module using non-contact vibration signals were detected while shaker vibration frequencies from 30Hz to 1,100 Hz at intervals of vibrating metallic specimens. Experimental results, Vibration frequency detection range of the metallic specimins within close proximity to contactless 5mm could be measured from DC to 1,100Hz and vibration amplitude of the resolution was $20{\mu}m$. Therefore, the proposed non-contact inductive sensor module for precision vibration detection sensor is estimated to have sufficient performance.

Development of an Optimum Void Detection Chart using Heat Transfer Simulation (열전달 시뮬레이션을 통한 최적공극탐지 차트개발)

  • Choi, Hyun-Ho;Park, Jin-Hyung;Ji, Goang-Seup
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.241-244
    • /
    • 2006
  • It is essential to develop a large capacity, non-contact nondestructive inspection system having high reliability to investigate repaired and strengthened structures. Nowadays, an infrared camera is widely used in non-contact nondestructive inspection system. Because an infrared camera is sensitive to the surrounding environment, it is necessary to improve a sensitivity of thermal image information and a relationship between defects and thermal image information. In this papaer, presented is an optimum void detection chart for the optimum conditions to detect infrared rays from inside and outside defects like voids and cracks in concrete structures using extensive computer simulation. Sensitivity studies are performed with respect to variables influencing the temperature distribution such as heating temperature, heating time, and geometries of defect, etc. It may be stated that it could be successfully utilized for the non-contact nondestructive inspection system to detect defects in concrete structures.

  • PDF

Guided-Wave Tomographic Imaging of Plate Defects by Laser-Based Ultrasonic Techniques

  • Park, Junpil;Lim, Juyoung;Cho, Younho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.6
    • /
    • pp.435-440
    • /
    • 2014
  • Contact-guided-wave tests are impractical for investigating specimens with limited accessibility and rough surfaces or complex geometric features. A non-contact setup with a laser-ultrasonic transmitter and receiver is quite attractive for guided-wave inspection. In the present work, we developed a non-contact guided-wave tomography technique using the laser-ultrasonic technique in a plate. A method for Lamb-wave generation and detection in an aluminum plate with a pulsed laser-ultrasonic transmitter and Michelson-interferometer receiver was developed. The defect shape and area in the images obtained using laser scanning, showed good agreement with the actual defect. The proposed approach can be used as a non-contact online inspection and monitoring technique.

Non-contact Detection of Ultrasonic Waves Using Fiber Optic Sagnac Interferometer (광섬유 Sagnac 간섭계를 이용한 초음파의 비접촉식 감지)

  • Lee, Jeong-Ju;Jang, Tae-Seong;Lee, Seung-Seok;Kim, Yeong-Gil;Gwon, Il-Beom;Lee, Wang-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.9
    • /
    • pp.1400-1409
    • /
    • 2001
  • This paper describes a fiber optic sensor suitable for non-contact detection of ultrasonic waves. This sensor is based on a fiber optic Sagnac interferometer. Quadrature phase bias between two interfering laser beams in Sagnac loop is introduced by a polarization controller. A stable quadrature phase bias can be confirmed by observing the interferometer output versus phase bias. This method eliminates a digital signal processing for detection of ultrasonic waves using Sagnac interferometer. Interference intensity is affected by the frequency of ultrasonic waves and the time delay of Sagnac loop. Collimator is attached to the end of the probing fiber to focus the light beam onto the specimen surface and to collect the reflected light back into the fiber probe. Ultrasonic waves produced by conventional ultrasonic transducers are detected. This fiber optic sensor based on Sagnac interferometer is very effective for detection of small displacement with high frequency such as ultrasonic waves used in conventional non-destructive testing.

Investigation of Standard Error Range of Non-Contact Thermometer by Environment (외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정)

  • Kim, Jeongeun;Park, Sangwoong;Choi, Heakyung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

TSV Fault Detection Technique using Eye Pattern Measurements Based on a Non-Contact Probing Method (Eye 패턴을 사용한 비접촉 형태의 TSV 고장 검출 기법)

  • Kim, Youngkyu;Han, Sang-Min;Ahn, Jin-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.592-597
    • /
    • 2015
  • 3D-IC is a novel semiconductor packaging technique stacking dies to improve the performance as well as the overall size. TSV is ideal for 3D-IC because it is convenient for stacking and excellent in electrical characteristics. However, due to high-density and micro-size of TSVs, they should be tested with a non-invasive manner. Thus, we introduce a TSV test method on test prober without a direct contact in this paper. A capacitive coupling effect between a probe tip and TSV is used to discriminate small TSV faults like voids and pin-holes. Through EM simulation, we can verify the size of eye-patterns with various frequencies is good for TSV test tools and non-contact test will be promising.

Study on Non-contact Detection of Surface Cracks of the Metals Using an Open-Ended Coaxial Line Sensor at X-band (마이크로파 X-밴드에서의 종단 개방 동축선 센서를 이용한 금속표면균열의 비접촉 검출 연구)

  • Yang, Seung-Hwan;Kim, Dong-Seok;Kim, Ki-Bok;Kim, Jong-Heon;Kang, Jin-Seob
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.192-197
    • /
    • 2012
  • In this paper, a non-contact microwave technique was presented to detect the surface crack of the metals. An open-ended coaxial cable line was used as a sensor at 11 GHz, and the reflection coefficients were measured by scanning along the metal surface including artificial surface cracks. A parameter, the K value which was defined as the difference between maximum and minimum reflection coefficients, was measured and used to estimate the crack depth. A linear relationship between the K value and crack depth was found. This study showed that non-contact detection of the surface cracks of metals is possible using the open-ended coaxial line sensor at X-band.

Development and Application of Non-Contact Rock Fall Detection System utilizing Photo Sensor and Camera (광센서와 카메라를 활용한 비접촉식 낙석감지 시스템 개발 및 적용)

  • Jung, Yong-Bok;Song, Won-Kyong;Kim, Bok-Chul;Kim, Myung-Jin
    • Tunnel and Underground Space
    • /
    • v.20 no.3
    • /
    • pp.207-216
    • /
    • 2010
  • Rockfall monitoring systems generally used in the country are mainly based on the detection of tension of protection wire or tilting of protection post due to rock fall. However, rock fall protection net must be installed prior to the monitoring system and continual maintenance work after each rock fall event is required for a normal operation of these detection systems. To solve these problems, we suggested and implemented a non-contact rock fall detection system using multiple photo sensors and additional camera. After a laboratory experiment and field application, we can conclude that this system is effective and reliable for detecting, collecting and analyzing the rock fall information. In addition, lighten and difference operations on two captured images were able to yield rough estimation of size and direction of rock fall.