• Title/Summary/Keyword: noise measuring method

Search Result 483, Processing Time 0.03 seconds

A Study on the Co-LMS Algorithm Characteristics of Real-time Applicants for Road Environment Calming (도로환경 정온화의 실시간 적용을 위한 Co-LMS 알고리즘의 특성 고찰)

  • Moon, Hak-Ryong;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.157-162
    • /
    • 2014
  • The active noise control(ANC) method for noise problems solution generally uses filtered-X LMS algorithms. However, Filtered-X LMS algorithms were mainly used but these had a limitation that had to measure a transfer function of secondary noise path. However, newly proposed correlation-LMS algorithms have slightly much calculation and are minutely behind performance, these have a advantage not in measuring transfer function onerously so that we can easily adapt these in real time. Thus Co-LMS algorithm was developed to improve the real-time implementation performance under the variable input noise such as road noise environment. In this paper, the performance of the Co-LMS is presented in comparison with that of the Filtered-X LMS algorithm. Simulation results show that active noise control using Co-LMS have slightly much calculation and are minutely behind performance, these have a advantage not in measuring transfer function onerously so that we can easily adapt these in real time.

Battery Internal Resistance Measurement System Robust to Charger Harmonic Noise (충전기 고조파 잡음에 강인한 배터리 내부저항 측정 시스템)

  • Lee, Hyung-Kyu;Kim, Gi-Taek
    • Journal of IKEEE
    • /
    • v.24 no.4
    • /
    • pp.1129-1135
    • /
    • 2020
  • The effects of battery aging limit the rechargeable capacity, State of Health(SoH). It is very important to estimate the SoH in the battery monitoring system(BMS) and many algorithms of measuring the internal resistance of the battery were proposed. A method is used by applying a current source of a specific frequency to the battery and measuring the voltage response. When charging harmonic noise is generated in the voltage response, it results in poor resistance measurement accuracy. In this paper, a robust battery internal resistance measurement algorithm is proposed to eliminate the effect of charging noise by integrating the current source and voltage response signals for a certain period. It showed excellent accuracy and stable measurement results. Applying to the BMS for uninterruptible power supply, the usefulness of the proposed method is verified.

An study on the Noise rating of water supply and drain installations in apartment bathroom (급배수 설비소음 평가방법 선정을 위한 실험적 연구)

  • Lee, Tai-Kang;Ko, Kwang-Pil;Choi, Eun-Seok;Kim, Hang;Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.57-64
    • /
    • 2007
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. The measurement procedure of water installations noise in apartment bathroom were established, so it is necessary to provide the evaluating method and criteria to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. After measuring the noise emission from the installations in many apartment bathroom, The noise were evaluated dB(A), N, NC index, To induce the appropriate method, the coefficient of the correlation among the evaluated numbers were analyzed. As a result, the dB(A) method is most easy to evaluating and very high correlated with N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

A Study on the Power Level Measurement and Evaluating Vocabulary of H.D. TV Sets -Focused on LCD·PDP Tv Sets- (고화질 TV Set의 음향 파워 레벨 측정 및 평가 어휘 선정에 관한 실험적 연구 - LCD·PDP TV Set를 중심으로 -)

  • Lee, Tai-Gang;Park, Hyeon-Ku;Lee, Ju-Yeob;Lee, Jai-Cheon;Shin, Jong-Keun;Kim, Hye-Jin;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1092-1099
    • /
    • 2005
  • This experimental study deals with the characteristics of LCD or PDP TV set noise, which are differ form those of CRT TV set. These characteristics are most important for establishing the effective method to reduce noise level, searching for the appropriate exposure level and evaluation method of LCD or PDP TV set noise. This study adopt two measurement method to specify the power level of LCD or PDP TV set noise in anechoic room(ISO 3741) and reverberation room(ISO 3745) . Comparing with each results of the two method, the reverberation room method is more simple in measuring and calculating the power level. And the subjective response test are carried out to select the pair of appropriate adjectives to present the characteristics of LCD or PDP TV set noise. The pair of 17 adjectives are selected from the 168 adjectives which are used in presenting the sound and noise form literature.

A study on the method for calculation the floor impact sound (바닥충격음 예측법에 관한 연구)

  • 이성호;정갑철
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.184-190
    • /
    • 2003
  • In this study, several methods for measuring floor impact sound were introduced. Among them, the simple methods (impedance method and diffuse index method) which can be easily applied to site works were investigated. Moreover, the comparison between the calculation results using diffuse index method and the experimental results measured in real apartment structures was conducted. Consequently, the modified diffuse index method, which can be practically used for predicting the performance of to the floor impact sound of apartment structures and can meet the allowable tolerance of Grade I (${\pm}$5㏈), was proposed.

  • PDF

Simplified method on measurement and evaluation of floor impact sound using impact ball (임팩트 볼에 의한 바닥충격음 측정 및 평가 간편법)

  • Kim, Yong-Hee;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.631-635
    • /
    • 2006
  • In this study, simplified methods on measurement and evaluation of heavy-wight impact sound was proposed due to provide easy quality control method to construction engineers. The simplified methods include using of rubber impact ball instead of bang machine, reduced number of measuring and impact positions which is prescribed as over 4 points, using of hand-held sound level meter as a frequency analyser and prediction equation for $L_{i.Fmax.AW}$, single number rating, using $L_{Amax}$, and $L_{Lmax}$ at each frequency band. The results showed that a method of boundary driving and boundary measuring is the most similar to the current rating method.

  • PDF

Quantitative Lateral Force Calibration of V-shaped AFM Cantilever (V 형상을 가지는 원자현미경 Cantilever의 정량적 마찰력 교정)

  • Lee, Huijun;Kim, Kwanghee;Kim, Hyuntae;Kang, Boram;Chung, Koo-Hyun
    • Tribology and Lubricants
    • /
    • v.28 no.5
    • /
    • pp.203-211
    • /
    • 2012
  • Atomic force microscopy (AFM) has been used as a tool, not only for imaging surfaces, but also for measuring surface forces and mechanical properties at the nano-scale. Force calibration is crucial for quantitatively measuring the forces that act between the AFM probe of a force sensing cantilever and a sample. In this work, the lateral force calibrations of a V-shaped cantilever were performed using the finite element method, multiple pivot loading, and thermal noise methods. As a result, it was shown that the multiple pivot loading method was appropriate for the lateral force calibration of a V-shaped cantilever. Further, through crosschecking of the abovementioned methods, it was concluded that the thermal noise method could be used for determining the lateral spring constants as long as the lateral deflection sensitivity was accurately determined. To obtain the lateral deflection sensitivity from the sticking portion of the friction loop, the contact stiffness should be taken into account.

Cleaning Method of Impulse Noise Using Mean Shift Segmentation (평균이동 분할을 이용한 임펄스 잡음제거)

  • Kwon, Young-Man;Lim, Myung-Jae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.9 no.6
    • /
    • pp.163-168
    • /
    • 2009
  • In this paper, We proposed the efficient method of cleaning impulse noise using mean shift segmentation. This method do its job for the pixel which is identified as impulse noise using mean shift segmentation instead of all pixel of image by the existing method. we found that the quality of image is improved by measuring the sum of square error in result image and impulse noise is cleaned efficiently by doing experiment.

  • PDF

Development of a continuous measuring system for derailment coefficient (탈선계수의 연속측정법 개발)

  • Ham Young-Sam
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.613-618
    • /
    • 2004
  • Is confirming safety of derailment when wish to develop new vehicles or upgrade running speed of vehicles. This means the measure of wheel load and lateral force that act between wheel and rail. So far, problem in continuous measuring method of derailment coefficient was sensitivity decline and noise growth. This research supplemented these problems by composition of new bridge circuit.

  • PDF

Noise Reduction Method for Particle Measurement System using Beta-ray Absorption Method (베타선 흡수법을 이용하는 미세먼지 측정시스템을 위한 잡음제거 방법)

  • Choi, Hun;Sohn, Sang-Wook;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1706-1712
    • /
    • 2012
  • The Beta-ray absorption method (BAM) gives a good solution for measuring the mass concentration of atmospheric particles(PM10 and PM2.5). To determine particular matters (PM) concentration, a ratio of the number of detected beta-ray intensity passing through the clean filter and the dust-sampled filter is used. These intensity data measured in air pollution monitoring such as PM10 and PM2.5 usually contained the additive noise(thermal noise, power supply noise and etc.). Therefore, the estimation performance of mass concentration can be deteriorated by these noises. In this paper, we present a new noise reduction method that is essentially required to develope an automatic continuous PM monitoring system using beta-ray absorption method. By combining the block data averaging technique and curve fitting, in the proposed method, the additive noise can be reduced in the measured data. To evaluate the performance of the proposed method, computer simulations were performed with computer generated signals as the input.