• Title/Summary/Keyword: needles

Search Result 687, Processing Time 0.024 seconds

Development of Very High Intensity Precharger of Electrostatic Precipitator for Diesel Particulates (디-젤배진용 강력전치하전장치의 개발)

  • Mun, Jae-Deok;Son, Hyeon;Seo, Bo-Hyeok;Kim, Gwang-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1984.07a
    • /
    • pp.226-229
    • /
    • 1984
  • A novel high intensity charging device has been developed for the control of the submicron particles, such as the diesel soot particulates, which are very hard to charge highly by any means of the conventional charging device. Having new corona electrodes of a multineedle disk with the corona field-control electrodes in the outer-cylinder electrode, extremely intense and stable coronas on there sharp points expanding both radially and axially are established in the corona charging region between the multi-corona -needles and an outer-cylinder electrode. As a result, the maximum corona field intensity and current density of the charging device of the standard one on soot load in laboratory tests have been 8.5KV/cm(E=$2V_m$/D(1nD/d)) and $6.5{\mu}A/cm^2$ which enhance greatly the charging of soot particles about several 100 times higher than those obtained in conventional cylinder precipitators.

  • PDF

A Study on the Characteristics of Micro Deep Hole Machining in Micro Drilling Machine (마이크로 드릴링 M/C에 의한 미세구멍가공특성에 관한 연구)

  • 민승기;이동주;이응숙;강재훈;김동우
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.275-280
    • /
    • 2001
  • Recently, the trends of industrial products grow more miniaturization, variety and mass production. Micro drilling which take high precision in cutting work is requested more micro hole and high speed working. Especially, Micro deep hole drilling is becoming more important in a wide spectrum of precision production industries, ranging from the production of automotive fuel injection nozzle, watch and camera parts, medical needles, and thick multi-layered Printed Circuit Boards(PCB) that are demanded for very high density electric circuitry. This paper shows the tool monitoring results of micro drill with tool dynamometer. And additionally, microscope with built-in monitor inspection show the relationship between burr in workpiece and chip form of micro drill machining.

  • PDF

Control of Laser Parameter for Precision Line Processing (미세 선가공을 위한 레이저 변수 제어)

  • Kim, Y.S.;Choi, E.S.;Shin, Y.J.
    • Laser Solutions
    • /
    • v.10 no.1
    • /
    • pp.11-17
    • /
    • 2007
  • We presented the proper laser processing conditions for the capillary line marking, which could be applied for the fabrication of injection needles. With changing the parameters such as lamp current, duty cycle and beam amplification factor of beam expander, we evaluated the processing performance considering amount of dross, processing efficiency and processed linewidth in the sample. We could carry out the proper line marking at the condition of 70% lamp current, duty cycle of 7-10% and 6-times amplification of beam diameter. To perform efficient line processing, the utilization of duty cycle of 12% at 80% lamp current was also preferred.

  • PDF

Dynamic Behavior of Heterogeneous Impinging Droplets onto High Temperature Plate (고온평판에 충돌하는 비균일혼합액적의 동적거동 특성)

  • Lee, Choong Hyun;Kim, Kyung Chun
    • Journal of the Korean Society of Visualization
    • /
    • v.13 no.3
    • /
    • pp.20-23
    • /
    • 2015
  • In this experiment, a heterogeneous droplet consisted of de-ionized water and olive oil was made through two 31G injection needles. The injection flow rate was $50{\mu}{\ell}/min$ and the droplet size was 2 mm. The droplet was impinged onto a sapphire plate which was heated up to $300^{\circ}C$ by a heater. Two high speed cameras were used for visualization, and the frame rate was 20,000 fps. A 150W metal halite lamp was used for illumination. The dropping height was fixed to 20 mm and the corresponding Weber number was 10.6 based on water. Due to different boiling points of two liquids, partial boiling features of heterogeneous droplet was observed. At the Leidenfrost condition, micro explosion phenomenon has occurred.

하치조신경 전달마취 중 파절된 주사바늘

  • Jang, Jung-Hui;Song, Min-Seok;Kim, Hyeon-Min;Kim, Nam-Hun;Eom, Min-Yong;Koo, Hyun-Mo;Yi, Jun-Kyu;Yang, Byeong-Eon
    • The Journal of the Korean dental association
    • /
    • v.44 no.2 s.441
    • /
    • pp.139-144
    • /
    • 2006
  • Local anesthesia is routine procedure in dental practices and has several complication. One of them, needle fracture is not uncommon in past, but rare in recent. The number of cases reported in the literature of broken needle in local anesthetic procedure has shown a marked decrease since the use of disposable spiral-constructed dental needle began. This complication results from lack of patient cooperation, inaccurate anesthetic technique, sudden movement of patient, error in the manufacturing procedure, use of short needle, and bending before use. Most common site is pterygomandibular space during inf. alveolar nerve block. In two patients, we removed broken needles under general anesthesia without complication. So we report cases with review of literatures.

  • PDF

Dielectric Characteristics of $SF_6$ Gas in Inhomogeneous Field (불평등 전계중에서 $SF_6$가스의 절연특성)

  • Lee, Chang-Jun;Lee, Bok-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1870-1872
    • /
    • 1996
  • This paper presents dielectric characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The propose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane and two needles-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was 22 mm and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

NOx Removal Using DC Corona Discharge Under Magetic Field (자계하의 DC 코로나 방전에 의한 NOx 제거)

  • Kim, G.H.;Kim, Jong-Dal;Lee, D.C.;Koh, H.S.;Park, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.462-464
    • /
    • 1995
  • In this paper, experiments were carried out to study the decrease of NOx in simulated flue gases (initial concentration of NO 1000, 750, 400 ppm, : $N_2$ balance gas). Characteristics of NOx reduction are measured and analysed in corona discharge of multi needles to plane electrode structure and magnetic field. The best characteristics of NO reduction is measured when electric and magnetic field were supplied to reactor, at same time. Consumption power applied electric and magnetic field were higher than that of discharge applied only electric field.

  • PDF

A Study on the Characteristics of DC Flashover with Floating Metallic Objects in Unipolar Ion Field (불평등 전계중에 금속구 및 금속침의 부유 물체가 존재하는 경우의 Flashover특성)

  • Seok, B.Y.;Huh, G.D.;Kim, K.S.;Cho, J.S.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.469-471
    • /
    • 1995
  • This paper describes the effect of floating metallic object on do flashover characteristics in all gap producing unipolar ion flow field. Needle-to-plane electrodes of 120mm in gap length were used as the main gap electrode and the tested metallic objects were spheres with the radius of 2,10 and 15mm or needles from 5 to 40mm long. The characteristics of flashover voltage vs. location of the floating object are different completely with the shape of the floating metal and polarity of the applied voltage.

  • PDF

STUDY ON THE BEHAVIOR OF NEEDLES AND SPRINGS FALLING FREELY IN A VISCOUS FLUID (점성 유체중에 자유낙하 하는 니들과 스프링의 거동에 관한 연구)

  • Gowtham, B.;Suh, Y.K.
    • Journal of computational fluids engineering
    • /
    • v.19 no.2
    • /
    • pp.30-39
    • /
    • 2014
  • We report in this paper the analysis of the motion of a needle and a spring in a viscous fluid under the influence of gravitational force. Lateral shift as well as vertical motion of a needle falling in a viscous fluid has been observed from a simple experiment. We also observed the combined rotation and translation of a falling spring. The trajectory and velocity of the falling needle and the spring were obtained by using an image processing technique. We also conducted numerical simulation for both problems. For the falling-needle problem, we employed a theory; but it turns out that significant correction is required for the solutions to match the numerical and experimental data. For the falling spring problem various theoretical formula were tested for their justification, but none of the existing theories can successfully predict the numerical and experimental results.

The Effect of Auricular Acupuncture Therapy on Blood Pressure (이침시술이 혈압에 미치는 영향)

  • 이진구;이영구;윤희식
    • The Journal of Korean Medicine
    • /
    • v.24 no.2
    • /
    • pp.12-18
    • /
    • 2003
  • Objectives : Hypertension is very prevalent disease, and causes serious cardiovascular complications. Nowadays optimal hypertension treatment is emphasized to reduce the incidence of cardiovascular complications. Auricular acupuncture therapy is economical, safe and effective. Its clinical application is various, and it can be used to control blood pressure. So The effect of auricular acupuncture therapy was investigated. Daily variation of blood pressure during needle-embedded period and variation of blood pressure by blood pressure classification were observed. Methods : The auricular acupuncture points we used were Gangapjeom (降壓點), Sinmun (神門), Gyogam (交感), Sim(心), and Icheom (耳尖). Auricular acupuncture needles were embedded for three days. Blood pressure was checked four times per day and the mean obtained. Results : The following results were obtained : 1. During needle-embedded period, systolic and diastolic blood pressure decreased. Blood pressure decreased most significantly 2 days after treatment. 2. The change of blood pressure in the higher blood pressure group was more remarkable than that of the lower blood pressure group. Conclusions : Through this research, auricular acupuncture therapy is considered as an effective and safe method to lower blood pressure.

  • PDF