• 제목/요약/키워드: nano operation

검색결과 213건 처리시간 0.03초

GaAs 기반 1300 nm 파장대역 InAs 양자점 레이저 다이오드의 발진 특성 (Lasing Characteristics of GaAs-Based 1300 nm Wavelength Region InAs Quantum Dot Laser Diode)

  • 김광웅;조남기;송진동;이정일;박정호;이유종;최원준
    • 한국진공학회지
    • /
    • 제18권4호
    • /
    • pp.266-271
    • /
    • 2009
  • Migration Enhanced Molecular Beam Epitaxy를 통해 성장한 GaAs 기반 1300 nm 파장대역 InAs 양자점 레이저 다이오드의 발진 특성을 연구하였다. 펄스 및 상온 연속 동작에서 전류 주입 및 동작 온도 변화에 따른 L-I 특성과 발진 스펙트럼 측정을 통해 바닥준위(1302 nm)에서 여기준위(1206 nm)로의 발진 파장의 전환을 관찰하였으며 이는 양자점 바닥준위 이득의 포화로 이해된다. 상온 펄스 동작시 문턱전류 밀도는 92 A/$cm^2$, 발진 파장은 1311 nm이며, 상온 연속 동작시 문턱전류 밀도는 247 A/$cm^2$, 발진 파장은 1320 nm이다.

연속 ECR-CVD 조업하에 RF-magnetron-sputter의 싸이클조업을 통해 PET위에 올려진 구리박막의 특성 (Characteristic of Copper Films on PET Substrate Deposited by Cyclic Operation of RF-magnetron-sputtering Coupled with Continuous Operation of ECR-CVD)

  • 명종윤;전법주;변동진;이중기
    • 한국재료학회지
    • /
    • 제15권7호
    • /
    • pp.465-472
    • /
    • 2005
  • Preparation of copper film on PET substrate was carried out by cyclic operation of RF-magnetron­sputtering under continuous operation of ECR-CVD. The purpose of this study is aimed to an increase in deposition rate with keeping excellent adhesion between copper film and PET. In order to optimize the sputtering time under continuous ECR-CVD, cyclic operation concept is employed. By changing parameters of cyclic operation such as split of e and cycle time of A, the characteristics and thickness of the deposited copper film are controlled. As $\theta$ value increase, film thickness could confirm to increase and its surface resistivity value decreases. The highest adhesive strength appears at $\theta=0.33$ and cycle time of 30 min. The uniformity of copper film shows $5\%$ in our experimental range.

Characterizations of Interface-state Density between Top Silicon and Buried Oxide on Nano-SOI Substrate by using Pseudo-MOSFETs

  • Cho, Won-Ju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권2호
    • /
    • pp.83-88
    • /
    • 2005
  • The interface-states between the top silicon layer and buried oxide layer of nano-SOI substrate were developed. Also, the effects of thermal treatment processes on the interface-state distributions were investigated for the first time by using pseudo-MOSFETs. We found that the interface-state distributions were strongly influenced by the thermal treatment processes. The interface-states were generated by the rapid thermal annealing (RTA) process. Increasing the RTA temperature over $800^{\circ}C$, the interface-state density considerably increased. Especially, a peak of interface-states distribution that contributes a hump phenomenon of subthreshold curve in the inversion mode operation of pseudo-MOSFETs was observed at the conduction band side of the energy gap, hut it was not observed in the accumulation mode operation. On the other hand, the increased interface-state density by the RTA process was effectively reduced by the relatively low temperature annealing process in a conventional thermal annealing (CTA) process.

중금속 검출용 고감도 나노표지센서 구현을 위한 볼타메트리 시스템 설계 연구 (A Study on Voltammetry System Design for Realizing High Sensitivity Nano-Labeled Sensor of Detecting Heavy Metals)

  • 김주명;이창규
    • 한국분말재료학회지
    • /
    • 제19권4호
    • /
    • pp.297-303
    • /
    • 2012
  • In this study, voltammetry system for realizing high sensitivity nano-labeled sensor of detecting heavy metals was designed, and optimal system operating conditions were determined. High precision digital to analog converter (DAC) circuit was designed to control applied unit voltage at working electrode and analog to digital converter (ADC) circuit was designed to measure the current range of $0.1{\sim}1000{\mu}A$ at counter electrode. Main control unit (MCU) circuit for controlling voltammetry system with 150 MHz clock speed, main memory circuit for the mathematical operation processing of the measured current value and independent power circuit for analog/digital circuit parts to reduce various noise were designed. From result of voltammetry system operation, oxidation current peaks which are proportional to the concentrations of Zn, Cd and Pb ions were found at each oxidation potential with high precision.

High Power Continuous-Wave and Graphene Q-switched Operation of Er:YAG Ceramic Lasers at ~1.6 ㎛

  • Wang, Yong;Chen, Hao;Shen, Deyuan;Zhang, Jian;Tang, Dingyuan
    • Journal of the Optical Society of Korea
    • /
    • 제17권1호
    • /
    • pp.5-9
    • /
    • 2013
  • We report on high-power continuous-wave operations of an Er:YAG ceramic laser in-band pumped by a cladding-pumped Er,Yb fiber laser at 1532 nm. With an output coupler of 10% transmission, the ceramic laser yielded 16.7 W of continuous-wave output at 1645 nm for 28.8 W of incident pump power, corresponding to a slope efficiency of 61.0% with respect to the incident pump power. The lasing wavelength switched to 1617 nm when output couplers of > 20% transmission were used. Up to 16.2 W of 1617 nm output was generated for 33.0 W of incident pump power, corresponding to a slope efficiency of 51.8%. Graphene Q-switched operation of Er:YAG cermic laser at 1645 nm was also demonstrated with stable pulses of 30-74 kHz repetition rates and 1.5-6.4 ${\mu}s$ pulse widths.

토끼 두개골 결손부에서 전기 방사된 나노실크-수산화인회석 복합체를 이용한 골재생 효과에 대한 연구 (Electrospun Silk Nano-Fiber Combined with Nano-Hydoxyapatite Graft for the Rabbit Calvarial Model)

  • 계준영;김성곤;김민근;권광준;박영욱;김좌영;이민정;박영환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권4호
    • /
    • pp.293-298
    • /
    • 2010
  • Purpose: The objective of the present study was to determine the capability of electrospun silk fibroin as a biomaterial template for bone formation when mixed with nano-hydoxyapatite in vivo. Materials and Methods: Ten New Zealand white rabbits were used for this study and bilateral round shaped defects were formed in the parietal bone (diameter: 8.0 mm). The electrospun silk fibroin was coated by nano-hydroxyapatite and grafted into the right parietal bone (experimental group). The left side (control group) did not receive a graft. The animals were sacrificed at 6 weeks and 12 weeks, humanly. The microcomputerized tomogram (${\mu}CT$) was taken for each specimen. Subsequently, they were undergone decalcification and stained for the histological analysis. Results: The average value of all measured variables was higher in the experimental group than in the control at 6 weeks after the operation. BMC in the experimental group at 6 weeks after operation was $48.94{\pm}19.25$ and that in the control was $26.17{\pm}16.40$ (P = 0.027). BMD in the experimental group at 6 weeks after operation was $324.59{\pm}165.24$ and that in the control was $173.03{\pm}120.30$ (P = 0.044). TMC in the experimental group at 6 weeks after operation was $19.50{\pm}6.00$ and that in the control was $10.52{\pm}6.20$ (P = 0.011). TMD in the experimental group at 6 weeks after operation was $508.88{\pm}297.57$ and that in the control was $273.54{\pm}175.91$ (P = 0.06). Gross image of both groups showed higher calcification area at 12 weeks than them in 6 weeks. The average value of ${\mu}CT$ analysis was higher at 12 weeks than that in 6 weeks in both groups. BMC in the experimental group at 12 weeks after operation was $51.21{\pm}8.81$ and that in the control was $33.47{\pm}11.13$ (P = 0.010). BMD in the experimental group at 12 weeks after operation was $323.39{\pm}21.54$ and that in the control was $197.75{\pm}76.23$ (P = 0.012). TMC in the experimental group at 12 weeks after operation was $21.44{\pm}5.30$ and that in the control was $13.31{\pm}4.17$ (P = 0.008). TMD in the experimental group at 12 weeks after operation was $524.47{\pm}19.37$ and that in the control was $299.60{\pm}136.20$ (P = 0.016). Conclusion: The rabbit calvarial defect could be successfully repaired by electrospun silk nano-fiber combined with nano-hydroxyapatite.

FIELD EXPERIENCE OF PORTABLE SMPS+C NANO PARTICLE SIZER

  • Gerhart, Ch.;Grimm, H.J.;Heim, M.
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.47-48
    • /
    • 2003
  • This new family of portable real time SEQUENTIAL MOBILITY PARTICLE COUNTER and SIZER (SMPS+C) is designed for mobility and easy field use. An integrated battery assures hours of operation, a data logger system storage of all optioned results and a user friendly powerful software easy operation. This technology not only simplifies the SMPS operation, but it permits new on site application monitoring up to a remote wireless telephone operation. (omitted)

  • PDF

화소 전극 간 거리가 Fringe In-plane field Switching mode의 전기 광학 특성에 미치는 영향 (Electro-Optic Characteristics according to Distance between Pixel Electrodes in Fringe In-plane field Switching mode)

  • 김민수;박지웅;정준호;하경수;임영진;이명훈;이승희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 추계학술대회 논문집 Vol.21
    • /
    • pp.337-338
    • /
    • 2008
  • We have studied electro-optic characteristics of a high performance liquid crystal display using Fringe In-plane field Switching (FIS) mode. The strong electric fields cause more liquid crystals to reorient almost in plane above and between the pixel electrodes. As a result, the operation voltage is lower and transmittance is higher than those of Fringe Field Switching (FFS) and In-Plane Switching (IPS) modes. Apparently, the transmittance depends on voltage applied at the configurations of FIS mode which are proposed. Therefore, we have studied certain length of between electrodes for maximum transmittance and light intensity.

  • PDF

PPS시스템 이용 바이오디젤 혼합율에 따른 극미세입자 배출특성 비교 (Comparison of Nano-particle Emission Characteristics in CI Engine with Various Biodiesel Blending Rates by using PPS System)

  • 권지원;김민식;정명철;이진욱
    • 한국분무공학회지
    • /
    • 제17권3호
    • /
    • pp.134-139
    • /
    • 2012
  • The main purpose of this study is to analyze and compare the nano-particle emission characteristics by 3-different biodiesel blending rates in a CI engine. Nano-particle number density emitted from various operating conditions of compression ignition engine can be investigated by using the PPS (Pegasor Particle Sensor) system. Namely, some particle charged through the corona discharge in real-time can be measured by PPS system. Under the steady state operation of the 2.0L CRDi diesel engine with different operating condition and biodiesel blending rates, the nano-particle number density was analyzed at the downstream position of DOC system. As this research result, more engine load speed and higher the concentration of biodiesel blending rate showed that the nano-particle number density decreases. Also we found that DOC system for clean diesel engine is effectively useful instrument to reduce diesel particulate matter as resource of nano-particle generation.

선부자를 적용한 하악골 골절환자의 치주조직에 기능성 치약이 미치는 영향 (THE EFFECT OF GINGIVAL GEL ON PERIODONTIUM IN MANDIBULAR FRACTURE PATIENTS APPLIED BY ARCH BAR)

  • 김선민;김경욱
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제35권2호
    • /
    • pp.125-130
    • /
    • 2009
  • For many years, intermaxillary fixation using arch bar has been operated in treatment of mandibular fracture patients. But it has many complications including injury of operators and assistants cause by wire, inflammation of periodontium. For that reasons alternatives are required; osteosynthesis technique using mini plate, intermaxillary fixation using IMF screws have been available. Treatment by arch bar fixation, however, is still valuable to treat craniomaxillary fracture patients. The purpose of this study is to know effect arch bar on periodontium and influence gingival gel on periodontium applied by arch bar. 40 mandibular fracture patients are monitored. 30 patients were applied by arch bar, 10 patients were not. And the former were classified by 3 categories; Nano vitamin and Mastic gel were applied to 10 patients respectively and any gingival gel was not used to 10 patients. Clinical attachment level, bleeding on probing and periodontal depth of each group were measured and compared before operation and on 2 weeks and 6 weeks after operation. Mann-Whitney U test was used to analyze result which leads to this conclusion. 1. Whether arch bar is applied or not, treatment of mandlbular fracture gave rise to gingivitis, but 6 weeks after operation, gingivitis is restored to the same level as the state before operation. 2. More severe gingivitis appeared when arch bar is applied to mandibular fracture than when it is not. 3. Both gingival gel used in this study can reduce gingivitis which can be caused by arch bar. 4. In this study, Mastic gel is more effective for prevent gingival inflammation cause by arch bar than nano vitamin. In regard to this result, gingivitis is considered to be available because it is reversible and does not induce periodontal disease. Gingival gel is regarded to be helpful for patients applied by arch bar to feel less discomfort.