• Title/Summary/Keyword: motion simulator

Search Result 384, Processing Time 0.03 seconds

A Study on the Measurement Method of Spatial Position Compensation for Virtual Reality and Real Space Synchronization (가상현실과 실공간 동기화를 위한 공간 위치보정 측정 방법론에 대한 연구)

  • Park, Kee-Jin;Lee, Byoung-Hwak;Kim, Nam-Hyuk;Yoon, Sung-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.136-143
    • /
    • 2018
  • Recently, with the rapid development of virtual reality technology, there have been more and more applications of virtual reality technology in various fields. In order to realize a virtual reality, a method of implementing a visualization environment through an HMD (Head Mounted Display) is widely used. However, in the current visualization environment through the HMD, the user feels dizziness when worn, It has the disadvantage of imposing restrictions on. In this study, it is aimed to realize virtual reality visualization environment through multi-screen environment which improves the experience effect of virtual environment by using existing screen instead of visualization through HMD, and compensates for shortcomings of HMD method. In order to realize a multi-screen environment as a highly visualized environment, a technique for matching the spatial position of the multi-screen with the spatial position of the virtual environment is required. To do this, we need an efficient method to precisely measure the position of the space, and we propose a spatial position compensation methodology that can efficiently and precisely measure the position of the real space and reflect it in the virtual environment.

Annoyance and sportiness perception of the acceleration sound by the driver and passengers (가속 사운드에 대한 운전자와 탑승객의 성가심과 스포티함 지각)

  • Kim, Seonghyeon;Altinsoy, M. Ercan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.6
    • /
    • pp.566-570
    • /
    • 2021
  • This study presents a perceptual difference in acceleration sounds of a sporty sedan between the driver and passenger. We found a significant difference in annoyance and sportiness perception according to the acceleration sound level through subjective evaluations. The multimodal reproduction system, which can reproduce the driving image, motion, vibration, and sound, was applied for the test. A subjective experiment was conducted to evaluate the perceived intensity of annoyance and sportiness by varying the acceleration sound level in five steps of 3 dB. The experimental results showed that the driver perceives the acceleration sound less annoying than the passenger at a relatively low sound level. Meanwhile, the driver has perceived the acceleration sound more sporty than the passenger at a relatively high sound level. Moreover, it was found that passengers were 35 % less sensitive to an annoyance than drivers, whereas the driver was 74 % more susceptible to sportiness than passengers according to the sound level change. This finding is expected to be applied as a sound design strategy that differentiates the acceleration sound level in active sound design.

Error Rate and Flight Characteristics of Rotary-Wing Aircraft Pilots Under Low Visibility Conditions (저시정 조건에서 회전익 항공기 조종사 에러 발생율 및 비행특성)

  • Se-Hoon Yim;Young Jin Cho
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.1
    • /
    • pp.60-67
    • /
    • 2024
  • The majority of civil aviation accidents are caused by human factors, and especially for rotary-wing aircraft, accidents often occur in situations where pilots unexpectedly or unintentionally enter into instrument meteorological conditions (IIMC). This research analyzed the error rates of rotary-wing aircraft pilots under low visibility conditions from various angles to gain insights into flight characteristics and to explore measures to reduce accidents in IIMC situations. The occurrence rate of errors by pilots under low visibility conditions was examined using a flight simulator equipped with motion, with 65 pilots participating in the experiment. Flight data obtained through the experiment were used to aggregate and analyze the number of errors under various conditions, such as reductions in flight visibility, the presence or absence of spatial disorientation, and the pilot's qualifications. The analysis revealed peculiarities in flight characteristics under various conditions, and significant differences were found in the rate of error occurrence according to the pilot's qualification level, possession of instrument flight rules (IFR) qualifications, and during different phases of flight. The results of this research are expected to contribute significantly to the prevention of aircraft accidents in IIMC situations by improving pilot education and training programs.

Development of Conformal Radiotherapy with Respiratory Gate Device (호흡주기에 따른 방사선입체조형치료법의 개발)

  • Chu Sung Sil;Cho Kwang Hwan;Lee Chang Geol;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.20 no.1
    • /
    • pp.41-52
    • /
    • 2002
  • Purpose : 3D conformal radiotherapy, the optimum dose delivered to the tumor and provided the risk of normal tissue unless marginal miss, was restricted by organ motion. For tumors in the thorax and abdomen, the planning target volume (PTV) is decided including the margin for movement of tumor volumes during treatment due to patients breathing. We designed the respiratory gating radiotherapy device (RGRD) for using during CT simulation, dose planning and beam delivery at identical breathing period conditions. Using RGRD, reducing the treatment margin for organ (thorax or abdomen) motion due to breathing and improve dose distribution for 3D conformal radiotherapy. Materials and Methods : The internal organ motion data for lung cancer patients were obtained by examining the diaphragm in the supine position to find the position dependency. We made a respiratory gating radiotherapy device (RGRD) that is composed of a strip band, drug sensor, micro switch, and a connected on-off switch in a LINAC control box. During same breathing period by RGRD, spiral CT scan, virtual simulation, and 3D dose planing for lung cancer patients were peformed, without an extended PTV margin for free breathing, and then the dose was delivered at the same positions. We calculated effective volumes and normal tissue complication probabilities (NTCP) using dose volume histograms for normal lung, and analyzed changes in doses associated with selected NTCP levels and tumor control probabilities (TCP) at these new dose levels. The effects of 3D conformal radiotherapy by RGRD were evaluated with DVH (Dose Volume Histogram), TCP, NTCP and dose statistics. Results : The average movement of a diaphragm was 1.5 cm in the supine position when patients breathed freely. Depending on the location of the tumor, the magnitude of the PTV margin needs to be extended from 1 cm to 3 cm, which can greatly increase normal tissue irradiation, and hence, results in increase of the normal tissue complications probabiliy. Simple and precise RGRD is very easy to setup on patients and is sensitive to length variation (+2 mm), it also delivers on-off information to patients and the LINAC machine. We evaluated the treatment plans of patients who had received conformal partial organ lung irradiation for the treatment of thorax malignancies. Using RGRD, the PTV margin by free breathing can be reduced about 2 cm for moving organs by breathing. TCP values are almost the same values $(4\~5\%\;increased)$ for lung cancer regardless of increasing the PTV margin to 2.0 cm but NTCP values are rapidly increased $(50\~70\%\;increased)$ for upon extending PTV margins by 2.0 cm. Conclusion : Internal organ motion due to breathing can be reduced effectively using our simple RGRD. This method can be used in clinical treatments to reduce organ motion induced margin, thereby reducing normal tissue irradiation. Using treatment planning software, the dose to normal tissues was analyzed by comparing dose statistics with and without RGRD. Potential benefits of radiotherapy derived from reduction or elimination of planning target volume (PTV) margins associated with patient breathing through the evaluation of the lung cancer patients treated with 3D conformal radiotherapy.

The effects of driving performance during driving with sending text message and searching navigation : a study among 50s taxi drivers (운전 중 문자 메시지 전송과 네비게이션 검색이 운전 수행 능력에 미치는 영향 : 50대 택시 운전자를 대상으로)

  • Kim, Han-Soo;Choi, Jin-Seung;Kang, Dong-Won;Oh, Ho-Sang;Seo, Jung-Woo;Yeon, Hong-Won;Choi, Mi-Hyun;Min, Byung-Chan;Chung, Soon-Cheol;Tack, Gye-Rae
    • Science of Emotion and Sensibility
    • /
    • v.14 no.4
    • /
    • pp.571-580
    • /
    • 2011
  • The purpose of this study was to evaluate the effects of secondary task such as sending text message (STM) and searching navigation (SN) using the variable indicating control of vehicle ((Medial-Lateral Coefficient of Variation, MLCV), (Anterior-Posterior Coefficient of Variation, APCV)) and motion signal (Jerk-Cost function, JC). Participants included 50s taxi drivers; 14 males and 14 females. Participants were instructed to keep a certain distance (30m) from the car ahead with constant speed (80km/hr or 100km/hr). Experiement consisted of driving alone for 1minute and driving with secondary task for 1minute. Both MLCV and APCV were significantly increased during Driving + Sending Text Message(STM) and Driving + Searching Navigation(SN) than Driving only. Also, JC was increased during Driving + STM and Driving + SN than Driving only. In this study, we found that even in the experts group who are taxi driver and have 25 years driving experience, the smoothness of motion is decreased and the control of vehicle is disturbed when they were performing secondary tasks like sending text message or searching navigation.

  • PDF

Effects of Secondary Task on Driving Performance -Control of Vehicle and Analysis of Motion signal- (동시과제가 운전 수행 능력에 미치는 영향 -차량 통제 및 동작신호 해석을 중심으로-)

  • Mun, Kyung-Ryoul;Choi, Jin-Seung;Kang, Dong-Won;Bang, Yun-Hwan;Kim, Han-Soo;Lee, Su-Jung;Yang, Jae-Woong;Kim, Ji-Hye;Choi, Mi-Hyun;Ji, Doo-Hwan;Min, Byung-Chan;Chung, Soon-Cheol;Taek, Gye-Rae
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.613-620
    • /
    • 2010
  • The purpose of this study was to quantitatively evaluate the effects of the secondary task while simulated driving using the variable indicating control of vehicle and smoothness of motion. Fifteen healthy adults having 1~2years driving experience were participated. 9 markers were attached on the subjects' upper(shoulder, elbow, Wrist) and lower(knee, ankle, toe) limbs and all subjects were instructed to keep the 30m distance with the front vehicle running at 80km/hr speed. Sending text message(STM) and searching navigation(SN) were selected as the secondary task. Experiment consisted of driving alone for 1 min and driving with secondary task for 1 min, and was defined driving and cognition blocks respectively. To indicate the effects of secondary task, coefficient of variation of distance between vehicles and lane keeping(APCV and MLCV) and jerk-cost function(JC) were analyzed. APCV was increased by 222.1% in SN block. MLCV was increased by 318.2% in STM and 308.4% in SN. JC were increased at the drivers' elbow, knee, ankle and toe, especially the total mean JC of lower limbs were increased by 218.2% in STM and 294.7% in SN. Conclusively, Performing secondary tasks while driving decreased the smoothness of motion with increased JC and disturbed the control of vehicle with increased APCV and MLCV.

  • PDF

Motor Control IP Design and Quality Evaluation from the Viewpoint of Reuse (ICCAS 2004)

  • Lee, Sang-Deok;Han, Sung-Ho;Kim, Min-Soo;Park, Young-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.981-985
    • /
    • 2004
  • In this paper we designed the motor control IP Core and evaluate its quality from the viewpoint of IP reuse. The most attractive merit of this methodology, so called IP-based hardware design, is hardware reuse. Although various vendors designed hardware with the same specification and got the same functional results, all that IPs is not the same quality in the reuse aspect. As tremendous calls for SoC have been increased, associated research about IP quality standard, VSIA(Virtual Socket Interface Alliance) and STARC(Semiconductor Technology Academic Research Center), has been doing best to make the IP quality evaluation system. And they made what conforms to objective IP design standard. We suggest the methodology to evaluate our own designed motor control IP quality with this standard. To attain our goal, we designed motor control IP that could control the motor velocity and position with feedback compensation algorithm. This controller has some IP blocks : digital filter, quadrature decoder, position counter, motion compensator, and PWM generator. Each block's functionality was verified by simulator ModelSim and then its quality was evaluated. To evaluate the core, We use Vnavigator for lint test and ModelSim for coverage check. During lint process, We adapted the OpenMORE's rule based on RMM (Reuse Methodology Manual) and it could tell us our IP's quality in a manner of the scored value form. If it is high, its quality is also high, and vice versa. During coverage check ModelSim-SE is used for verifying how our test circuits cover designs. This objective methods using well-defined commercial coverage metrics could perform a quantitative analysis of simulation completeness. In this manner, We evaluated the designed motor control IP's quality from the viewpoint of reuse. This methodology will save the time and cost in designing SoC that should integrate various IPs. In addition to this, It can be the guide for comparing the equally specified IP's quality. After all, we are continuously looking forward to enhancing our motor control IP in the aspect of not only functional perfection but also IP reuse to prepare for the SoC-Compliant motor control IP design.

  • PDF

Experimental Study on Fretting Wear of Inconel 690 Under High Temperatures and Pressures (고온 고압 환경에서 인코넬 690 재료의 프레팅 마모 특성에 관한 실험적 연구)

  • Lee, Coon-Yeol;Lee, Ju-Suck;Bae, Joon-Woo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.6
    • /
    • pp.637-644
    • /
    • 2012
  • In a nuclear power plant, fretting wear due to impact motion between U-tubes and support structures located in steam generators can cause serious problems. In order to guarantee the reliability of the steam generator, the damage due to fretting wear should be thoroughly investigated. The purpose of this study is to elucidate the fretting wear mechanism qualitatively and quantitatively. Hence, fretting wear simulation is performed for the environments to which the actual steam generators in nuclear power plants are exposed. Initial experimental results are obtained for various experimental parameters, and the effect of the work rate and temperature on fretting wear is evaluated. In water, the wear coefficients for $90^{\circ}C$, $200^{\circ}C$, and $340^{\circ}C$ are found to be $9.051{\times}10^{-16}\;Pa^{-1}$, $3.009{\times}10^{-15}\;Pa^{-1}$, and $2.235{\times}10^{-15}\;Pa^{-1}$, respectively. It is also found that the wear coefficient at room temperature is larger than that at low temperature in water because of the dynamic viscosity of water.

Comparison of Newton's and Euler's Algorithm in a Compound Pendulum (복합진자 모형의 뉴튼.오일러 알고리즘 비교)

  • Hah, Chong-Ku
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The Primary type of swinging motion in human movement is that which is characteristic of a pendulum. The two types of pendulums are identified as simple and compound. A simple pendulum consist of a small body suspended by a relatively long cord. Its total mass is contained within the bob. The cord is not considered to have mass. A compound pendulum, on the other hand, is any pendulum such as the human body swinging by hands from a horizontal bar. Therefore a compound pendulum depicts important motions that are harmonic, periodic, and oscillatory. In this paper one discusses and compares two algorithms of Newton's method(F = m a) and Euler's method (M = $I{\times}{\alpha}$) in compound pendulum. Through exercise model such as human body with weight(m = 50 kg), body length(L = 1.5m), and center of gravity ($L_c$ = 0.4119L) from proximal end swinging by hands from a horizontal bar, one finds kinematic variables(angle displacement / velocity / acceleration), and simulates kinematic variables by changing body lengths and body mass. BSP by Clauser et al.(1969) & Chandler et al.(1975) is used to find moment of inertia of the compound pendulum. The radius of gyration about center of gravity (CoG) is $k_c\;=\;K_c{\times}L$ (단, k= radius of gyration, K= radius of gyration /segment length), and then moment of inertia about center of gravity(CoG) becomes $I_c\;=\;m\;k_c^2$. Finally, moment of inertia about Z-axis by parallel theorem becomes $I_o\;=\;I_c\;+\;m\;k^2$. The two-order ordinary differential equations of models are solved by ND function of numeric analysis method in Mathematica5.1. The results are as follows; First, The complexity of Newton's method is much more complex than that of Euler's method Second, one could be find kinematic variables according to changing body lengths(L = 1.3 / 1.7 m) and periods are increased by body length increment(L = 1.3 / 1.5 / 1.7 m). Third, one could be find that periods are not changing by means of changing mass(m = 50 / 55 / 60 kg). Conclusively, one is intended to meditate the possibility of applying a compound pendulum to sports(balling, golf, gymnastics and so on) necessary swinging motions. Further improvements to the study could be to apply Euler's method to real motions and one would be able to develop the simulator.

The Effect of MLC Leaf Motion Constraints on Plan Quality and Delivery Accuracy in VMAT (체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가)

  • Kim, Yon-Lae;Chung, Jin-Beom;Lee, Jeong-woo;Shin, Young-Joo;Kang, Dong-Jin;Jung, Jae-Yong
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.217-222
    • /
    • 2019
  • The purpose of this study is to evaluate the dose distribution by gantry rotation and MLC moving speed on treatment planning system(TPS) and linear accelerator. The dose analyzer phantom(Delta 4) was scanned by CT simulator for treatment planning. The planning target volumes(PTVs) of prostate and pancreas was prescribed 6,500 cGy, 5,000 cGy on VMAT(Volumetric Modulated Arc Therapy) by TPS while MLC speed changed. The analyzer phantom was irradiated linear accelerator using by planned parameters. Dose distribution of PTVs were evaluated by the homogeneity index, conformity index, dose volume histogram of organ at risk(rectum, bladder, spinal cord, kidney). And irradiated dose analysis were evaluated dose distribution and conformity by gamma index. The PTV dose of pancreas was 4,993 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(5,000 cGy). The dose of spinal cord, left kidney, and right kidney were accessed the lowest during 0.1 cm/deg, 1.5 cm/deg, 0.3 cm/deg. The PTV dose of prostate was 6,466 cGy during 0.1 cm/deg leaf and gantry that was the most closest prescribed dose(6,500 cGy). The dose of bladder and rectum were accessed the lowest during 0.3 cm/deg, 2.0 cm/deg. For gamma index, pancreas and prostate were analyzed the lowest error 100% at 0.8, 1.0 cm/deg and 99.6% at 0.3, 0.5 cm/deg. We should used the optimal leaf speed according to the gantry rotation if the treatment cases are performed VMAT.