TCMS에 의한 전동차 추진/제동 제어기술의 현차시험 결과 고찰 (A Study for Running Test Result of Train Powering/Braking Control by TCMS)

  • 박성호;한정수;신광균;박계서
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.652-658
    • /
    • 2000
  • TCMS(Train Control & Management System) control monitor and test the main on-board equipments including propulsion/brake unit by the serial transmission line. TCMS reduces interface circuits and number of train lines by the software logic and utilizing serial communication method. This paper describes the method of powering and braking control by TCMS software logic, and the software logic is verified by running test at Seoul Subway Line# 6. By running test result, we can see TCMS successfully control Powering/Braking of train

  • PDF

배전자동화용 개폐기 시험용 소프트웨어 개발 (Distribution Automation Switch Testing Software Development)

  • 옥기정;김재성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 2001
  • We have developed the testing software for KEPCO operators to maintain the small-scale distribution automation system effectively. The testing software is used to monitor the present status, to measure the analog value(voltage, amperage) and to control the switch and FRTU(Feeder Remote Terminal Unit) in order to find out a disabled part of the system. And at the stage of inspection of the switch and FRTU, it can screen the inferior one.

  • PDF

TCMS에 의한 전동차 추진/제동 제어기법 (A Study of Train Powering/Braking Control by TCMS)

  • 한정수;박성호;김국진;박계서
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.291-298
    • /
    • 1999
  • TCMS(Train Control & Management System) is the management system of train information which intensively control, monitor and test the main on-board equipments including propulsion/brake unit by the serial transmission line. TCMS reduces interface circuits and number of train lines by the software logic and utilizing serial communication method. This paper describes the method of powering and braking control by TCMS software logic, in comparison with the powering/braking control by conventional relay logic/hardwire circuits, and the software logic was verified by simulation test with TCMS simulator.

  • PDF

자동게이트통관시스템용 DSRC 단말기의 성능 개선 (Performance Improvement of DSRC unit for Automatic Gate Clearance System)

  • 박상완;정봉식
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.187-190
    • /
    • 2002
  • In this paper, we deal with performance improvement of OBE for automatic gate clearance system by using DSRC network of 5.8GHz ISM band. A data format is improved to represent Rx and Tx information which is need to perform clearance at the gate of container terminal. An error message caused by data discordance is added to Previous data format. A graphic LCD monitor is used to control a character font and use Korean.

  • PDF

Design on SDS2 On-line Poison Concentration Monitoring in CANDU

  • Kim, Seog-Nam;Jung, Ho-Chang;Kim, Sung;Kim, Ji-Hyeon;Han, Sang-Joon
    • Nuclear Engineering and Technology
    • /
    • 제28권5호
    • /
    • pp.500-505
    • /
    • 1996
  • At the reference plant(Wolsong unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsong unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low.

  • PDF

연료전지 셀 전압 모니터링 방법에 관한 연구 (Fuel Cell Stack Cell Monitoring Method)

  • 김동락;김현;이치노세토시히코
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1031_1032
    • /
    • 2009
  • The voltages of unit cells of a fuel cell stack are one of the most significant factors to detect failure conditions and thereof safely control and operate the fuel cell system. In this paper, we describe two methods to monitor the voltages of the unit cells of a stack in consideration of data accuracy, circuit extensibility to various numbers of cells, and cost. The reported methods are approached by (i) the power isolation of cell voltage monitoring part from the communications part and (ii) the utilization of a commercially available cell monitoring integrated circuit IC of a Li-ion battery.

  • PDF

울진 1, 2호기의 중성자 잡음신호 분석 (Neutron Noise Analysis in Ulchin Nuclear Unit 1 & 2)

  • 김태룡;박진호;고병무;배용채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.582-589
    • /
    • 1998
  • This paper presents the analysis results of ex-core and in-core neutron noise, acceleration signals and pressure fluctuation measured at Ulchin Nuclear Unit 1 & 2 to identify and monitor the reactor internals vibration including fuel motion. A phase separation algorithm developed by authors was applied to the neutron noises to clearly identify the reactor internals vibratory motion. The beam mode frequency of the core support barrel was identified to be 8Hz and the shell mode to be 20Hz. The first frequency of the fuel assembly was also found to be 3Hz, while first two acoustic frequencies of the primary coolant system were 6 and 17.5Hz. By monitoring and analyzing these frequencies periodically, it is possible to diagnose the operating condition of reactor internals and to provide an early detection of faults for the predictive maintenance.

  • PDF

Biological Response Modifiers Influence Structure Function Relationship of Hematopoietic Stem and Stromal Cells in a Mouse Model of Leukemia

  • Basu, Kaustuv;Mukherjee, Joydeep;Law, Sujata;Chaudhuri, Samaresh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권6호
    • /
    • pp.2935-2941
    • /
    • 2012
  • Biological response modifiers (BRMs) can alter interactions between the immune system and cancer cells to boost, direct, or restore the body's ability to fight disease. Mice with ethylnitrosourea- (ENU) induced leukemia were here used to monitor the therapeutic efficacy of lipopolysaccaride (LPS), Bacillus Calmette Guerin (BCG) and sheep erythrocytes (SRBC). Flow cytometry based CD34+ positivity analysis, clonogenicity, proliferation and ultrastructure studies using scanning electron microscopy (SEM) of stem cells in ENU induced animals with and without BRMs treatment were performed. BRMs improved the stem-stromal relationship structurally and functionally and might have potential for use as an adjunct in human stem cell therapy.

가스절연개폐장치용 감시시스템 적용에 관한 연구 (A study on the Application of a Monitoring System for Gas Insulaterd Switchgear)

  • 김정배;김민수;송원표;김덕수;전찬석;길경석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권1호
    • /
    • pp.22-30
    • /
    • 2002
  • ln this paper, it was reported the developed results of the monitoring unit for 72.5kY GIS which it is one part of the monitoring system for the substation that Korea Railway Company is promoting. In order to monitor the operational status of GIS, four parameters were chosen: the number of times of the circuit breaker switching, tightness of the gas-sealed units (circuit breaker / disconnecting switch / earthing switch), the number of times of the lightning arrestor operating and the leakage current of the lighting arrester. We constructed the monitoring system that can be judged the operating condition of the GIS from the signal of the suitable sensor for the purpose. Therefore, it is possible to on line monitoring for the condition of the GlS without efforts of the Periodic inspection.

최대수요전력 관리 장치의 부하 예측에 관한 연구 (A Study on the Load Forecasting Methods of Peak Electricity Demand Controller)

  • 공인엽
    • 대한임베디드공학회논문지
    • /
    • 제9권3호
    • /
    • pp.137-143
    • /
    • 2014
  • Demand Controller is a load control device that monitor the current power consumption and calculate the forecast power to not exceed the power set by consumer. Accurate demand forecasting is important because of controlling the load use the way that sound a warning and then blocking the load when if forecasted demand exceed the power set by consumer. When if consumer with fluctuating power consumption use the existing forecasting method, management of demand control has the disadvantage of not stable. In this paper, load forecasting of the unit of seconds using the Exponential Smoothing Methods, ARIMA model, Kalman Filter is proposed. Also simulation of load forecasting of the unit of the seconds methods and existing forecasting methods is performed and analyzed the accuracy. As a result of simulation, the accuracy of load forecasting methods in seconds is higher.