• 제목/요약/키워드: microscopes

검색결과 295건 처리시간 0.021초

한국산 차나무과의 화분분류학적 연구 (A Palynotaxonomic Study on the Korean Theaceae)

  • 이상태
    • Journal of Plant Biology
    • /
    • 제30권3호
    • /
    • pp.215-223
    • /
    • 1987
  • Pollen grains of six geners and six species from Korean Theaceae were observed with light and scanning electron microscopes. Pollen morphology divided the investigated species into the tricolporoidate Theoideae and the tricolporate Ternstroemiodideae. On the basis of surface sculpturing pattern, further palynological relationships and classificatin were understood. Some of the nomenclatural problems were discussed along with the palynological results.

  • PDF

초고진공 저온 주사터널 현미경 장치의 최신 경향 (Current Trend of Ultrahigh Vacuum Low Temperature Scanning Tunneling Microscopy)

  • 함웅돈;염한웅
    • 진공이야기
    • /
    • 제3권4호
    • /
    • pp.14-18
    • /
    • 2016
  • 본 원고에서는 2010년대 중반 현재 초고진공 환경에서 작동 가능한 저온 주사터널 현미경의 세계적 흐름을 정리 및 소개를 한다. 벡터형 초전도 자석을 장착한, 저진동 초고진공용 희석식 냉동기의 개발에 힘입어 수십 밀리 켈빈 이하의 온도 대 및 10 테슬라의 고자기장하의 실험 조건을 가지는 밀리 켈빈 주사터널 현미경이 세계 선도 그룹에서 속속 구축이 완료되고 있다. 또한 2000년대 중반 이후 본격적으로 시작된 1 켈빈 이하 고자기장 냉동기를 이용한 저온 주사 터널 현미경의 응용 범위 역시 넓어지고 있다. 튜닝 포크를 이용한 저온 원자 힘 현미경 및 저온 광자 주사터널 현미경을 이용한 연구도 활발히 진행되고 있다. 이러한 논의를 바탕으로 2020년대에 본격 출현할 초고진공 저온 주사터널 현미경의 흐름을 예측해 보겠다.

Observation and Distribution of Ectomycorrhizal Fungi in Pinus Roots

  • Chung, Hung-Chae;Kim, Dong-Hun;Cho, Nam-Seok;Lee, Sang-Sun
    • Mycobiology
    • /
    • 제31권1호
    • /
    • pp.1-8
    • /
    • 2003
  • Detailed structures of ectomycorrhizae formed in Pinus roots were observed with various microscopes: light, fluorescence, and scanning electron microscopes. The mantles and Hartig nets commonly found in the structure of ectomycorrhiza were newly observed according to developmental stage by various staining. The mycelia were observed to be composed of coiled types on the surface of epidermal root during early stage and fused to form mantles of smooth fungal layers, loosing mycelia with some viscous liquid secreted. The ectomycorrhizal hyphae in anatomical roots penetrated the cortical layer and formed obviously mantle and Hartig net. The round spots of ectomycorrhizal mycelia were observed morphological distribution from the cortical layer to vascular bundle of stele in the ectomycorrhizal roots of Pinus species and especially scattered at the area of meristem at the root tip as longitudinal sections. Those mycelia penetrated seemed to move into other roots by means of vascular bundle of ectomycorrhizal roots and newly form ectomycorrhizal roots of dichotomous branches.

광 픽업 방식 형광스캐너를 이용한 미소유체 특성 분석 (Characterization of Microfluidic Channels using DVD Pick-up Fluorescent Scanner)

  • 임빛;김재현;이승엽;박정열
    • 대한기계학회논문집A
    • /
    • 제32권12호
    • /
    • pp.1102-1106
    • /
    • 2008
  • Microfluidics deals with the behavior, precise control and manipulation of fluids at a micro scale. It has become increasingly prevalent in various applications such as biomedical applications (diagnostics, therapeutics, and cell/tissue engineering), inkjet head, and fuel cells etc. The issue of inspection and characterization of microfluidics has emerged as a major consideration in design, fabrication, and detection of microfluidic devices. In this paper, we characterize a diffusion based mixing in Y-microchannel using a fluorescent optical scanner based on a DVD pick-up module, which is widely used in optical storages. Using fluorescent dye, we measure the fluorescent intensity that represents the mixing patterns in Y-microchannel. We also compare these experimental results with computational fluid dynamics (CFD) simulation ones. It is shown that the proposed optical scanner can be used as an alternative measurement system with high performance and cost-effectiveness, compared to conventional optical tools such as epifluorescent microscopes using high resolution CCD camera and confocal microscopes with photomultiplier (PMT) detectors.

Three dimensional dynamic response of functionally graded nanoplates under a moving load

  • Hosseini-Hashemi, Shahrokh;Khaniki, Hossein Bakhshi
    • Structural Engineering and Mechanics
    • /
    • 제66권2호
    • /
    • pp.249-262
    • /
    • 2018
  • In this paper, reaction of functionally graded (FG) thick nanoplates resting on a viscoelastic foundation to a moving nanoparticle/load is investigated. Nanoplate is assumed to be thick by using second order shear deformation theory and small-scale effects are taken into account in the framework of Eringen's nonlocal theory. Material properties are varied through the thickness using FG models by having power-law, sigmoid and exponential functions for material changes. FG nanoplate is assumed to be on a viscoelastic medium which is modeled using Kelvin-Voight viscoelastic model. Galerkin, state space and fourth-order Runge-Kutta methods are employed to solve the governing equations. A comprehensive parametric study is presetned to show the influence of different parameters on mechanical behavior of the system. It is shown that material variation in conjunction with nonlocal term have a significant effect on the dynamic deformation of nanoplate which could be used in comprehending and designing more efficient nanostructures. Moreover, it is shown that having a viscoelastic medium could play an important role in decreasing these dynamic deformations. With respect to the fresh studies on moving atoms, molecules, cells, nanocars, nanotrims and point loads on different nanosctructures using scanning tunneling microscopes (STM) and atomic force microscopes (AFM), this study could be a step forward in understanding, predicting and controlling such kind of behaviors by showing the influence of the moving path, velocity etc. on dynamic reaction of the plate.

고배율 광학현미경의 초정밀 능동 자동초점방법 (Active auto-focusing of high-magnification optical microscopes)

  • 이호재;이상윤;김승우
    • 한국광학회지
    • /
    • 제7권2호
    • /
    • pp.101-111
    • /
    • 1996
  • 최근들어 반도체 산업의 자동검사장비에 고배율 광학현미경이 많이 사용되고 있다. 이러한 고배율 광학현미경에 있어서 선결과제가 물체를 광학현미경에 사용된 대물렌즈의 초점심도 내에 위치시키는 초점맞춤작업이다. 본 논문에서는 광삼각법을 기본구성으로하고 수광부에 2개의 2분할소자를 사용함으로써 물체의 표면상태에 둔감하면서 물체의 초점오차량에는 매우 민감한 초점오차신호를 만들어줄 수 있는 새로운 자동초점방법을 소개하였다. 얻어진 실험결과에 의하면 이 방법의 신호분해능은 5nm이며, 반복능은 0.5.mu.m이다.

  • PDF

임상에서의 현미경: 작동, 유지보수 및 레이저 안전 (Clinical Microscopy: Performance, Maintenance and Laser Safety)

  • 이태복
    • 대한임상검사과학회지
    • /
    • 제51권2호
    • /
    • pp.125-133
    • /
    • 2019
  • 임상병리 검사분야에 있어서 환자로부터 유래된 조직이나 세포의 형태학적 변화, 세포 생리, 세포 내 분자의 추적 및 신호전달 체계 등의 임상검사 및 관련 연구를 위한 빼놓을 수 없는 주요한 진단과 연구장비로서 현미경이 가지는 의미는 크다고 할 수 있다. 현미경에 대한 포괄적인 지식과 이해를 바탕으로 현미경의 올바른 사용, 관리와 유지보수는 신뢰도 높은 이미지 획득과 그에 따른 정확한 데이터 분석을 통한 질병의 진단을 위해서 반드시 요구되는 부분이라고 할 수 있다. 광학현미경의 표준 운영 절차(standard operating procedure, SOP)는 현미경의 작동 절차와 함께 검사실 규모에 따른 현장 사용자의 체계적인 현미경 장해 해결 방안과 기계적 원리에 대한 핵심 정보가 함께 수록되어야 한다. 현미경 유지관리 업무에는 대물, 접안렌즈와 현미경 내부 광학필터의 청소, 광원의 교체와 교정, XY재물대 유지보수, 공초점 레이저 주사 현미경(confocal laser scanning microscope)에서의 점확산함수(point spread function, PSF) 측정, 형광현미경에서의 검사 품질관리(quality control, QC)와 체계적인 현미경 장해 해결방안 등이 포함되어야 한다. 본 종설에서는 국제적 기준에 따른 레이저의 위험도에 따라 일부 현미경에 장착된 레이저 광원에 대한 안전지침과 보호장구에 대한 내용을 함께 소개하였다. 현미경을 통해 획득된 이미지는 촬영된 시점의 검체에 대한 모든 정보를 제공한다고 할 수 있으며, 적절한 유지보수 프로그램과 그에 따라 적합하게 관리된 현미경만이 이미지 데이터를 통한 정보의 획득, 올바른 해석과 정확한 진단에 반드시 필요한 선제 조건들이라고 하겠다.

반사 모드 방식의 근접장 주사 광학 현미경을 이용한 표면 탄성파 필터의 영상 측정 (Optical Measurement of SAW Filter Using Reflection Mode NSOM)

  • 박경덕;정상철;김대찬;지원수;오범환;박세근;이일항;이승걸
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 동계학술발표회 논문집
    • /
    • pp.459-460
    • /
    • 2009
  • In this study, surface structure and near-field distribution of a surface acoustic wave filter were measured with both reflection mode and collection mode near-field scanning optical microscopes, and there results were compared with each other.

  • PDF

고배율 현미경의 자동초점장치 (An Auto-focusing system for a Iligh Resoulution Microscope)

  • 이호재;이상윤;공인복;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.255-260
    • /
    • 1993
  • This study proposed a new autofocusing method for a high resolution microscope with a depth of focus of a submicron range. The experimental setup was characterized by nulling method for bi-cell prhotodiode which had two active areas on sensor surface. The optical systems used in this method had was very simple and was easily matched to microscopes which had used widely. It was shown that the resolution was very high (about 20 nm) by experimental results. This method can be used in the semiconduct industry because it can find defects on the silcon wafer.

  • PDF

${\alpha}$-FeOOH 입자의 산화침전반응에 대한 침전제의 영향 (The Effect of Precipitants on the Oxidative Precipitation of ${\alpha}$-FeOOH Particles)

  • 천재기;이석희;구수진
    • 한국인쇄학회지
    • /
    • 제20권2호
    • /
    • pp.95-106
    • /
    • 2002
  • The effect of various precipitants on the sizes and the shapes was investigated using a scanning electron microscopes when the ${\alpha}$-FeOOH particles was possible in a selection of an appropriate precipitants after due considerations of the shape and the growth of particles.

  • PDF