• Title/Summary/Keyword: microleakage

Search Result 261, Processing Time 0.033 seconds

A COMPARATIVE STUDY ON THE MICROLEAKAGE OF THE AMALGAM AND GALLIUM ALLOY (아말감과 갈륨알로이의 미세 변연 누출에 관한 비교 연구)

  • Kim, Jung-Wook
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.323-334
    • /
    • 1998
  • The purpose of this study was to compare the microleakage of the amalgam and the gallium alloy when several lining materials were applied. The ANA 2000, high copper lathecut type amalgam(AM group) and Gallium Alloy GF II (GF group) were used. The fifty extracted sound molars were randomly assigned to AM group and GF group, and the buccal and lingual class V cavities with a size $3{\times}2{\times}2mm$ were prepared. The prepared cavities were randomly assigned to group 1 : no liner used control, group 2 : Copalite, group 3 : Panavia 21, group 4 : All-bond 2, and group 5 : Superbond C&B. After liner placement and amalgam filling, the specimens were stored in $37^{\circ}C$ normal saline for 24 hours and then thermocycled from $5^{\circ}C$ to $55^{\circ}C$ thousand times. The specimens were stored in the 1% methylene blue solution for 24 hours and sectioned and examined by stereomicroscope. The results obtained from this study can be summarized as follows : 1. In the GF group, microleakage values of group 2, 3, 4, 5 were significantly lower than that of group 1 (p<0.05). 2. In the AM group, microleakage values of group 3 and 4 were significantly lower than that of group 1 (p<0.05), but microleakage values of group 2 and 5 did not differ from that of group 1 (p>0.05). 3. The GF group was similar(group, 1 3, 4) or superior(group 2, 5) to the AM group in the aspect of the microleakage.

  • PDF

Marginal microleakage of cervical composite resin restorations bonded using etch-and-rinse and self-etch adhesives: two dimensional vs. three dimensional methods

  • Khoroushi, Maryam;Ehteshami, Ailin
    • Restorative Dentistry and Endodontics
    • /
    • v.41 no.2
    • /
    • pp.83-90
    • /
    • 2016
  • Objectives: This study was evaluated the marginal microleakage of two different adhesive systems before and after aging with two different dye penetration techniques. Materials and Methods: Class V cavities were prepared on the buccal and lingual surfaces of 48 human molars. Clearfil SE Bond and Single Bond (self-etching and etchand-rinse systems, respectively) were applied, each to half of the prepared cavities, which were restored with composite resin. Half of the specimens in each group underwent 10,000 cycles of thermocycling. Microleakage was evaluated using two dimensional (2D) and three dimensional (3D) dye penetration techniques separately for each half of each specimen. Data were analyzed with SPSS 11.5 (SPSS Inc.), using the Kruskal-Wallis and Mann-Whitney U tests (${\alpha}=0.05$). Results: The difference between the 2D and 3D microleakage evaluation techniques was significant at the occlusal margins of Single bond groups (p = 0.002). The differences between 2D and 3D microleakage evaluation techniques were significant at both the occlusal and cervical margins of Clearfil SE Bond groups (p = 0.017 and p = 0.002, respectively). The difference between the 2D and 3D techniques was significant at the occlusal margins of non-aged groups (p = 0.003). The difference between these two techniques was significant at the occlusal margins of the aged groups (p = 0.001). The Mann-Whitney test showed significant differences between the two techniques only at the occlusal margins in all specimens. Conclusions: Under the limitations of the present study, it can be concluded that the 3D technique has the capacity to detect occlusal microleakage more precisely than the 2D technique.

MARGINAL MICROLEAKAGE OF SELF-ETCHING PRIMER ADHESIVES AND A SELF-ETCHING ADHESIVE (자가 산부식 프라이머와 자가 산부식 접착제의 변연 미세누출)

  • Cho, Young-Gon;Cho, Kong-Chul
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.493-501
    • /
    • 2002
  • This study evaluated the microleakage performance of four self-etcing primer adhesives(Clearfil SE Bond, Clearfil Liner Bond 2, UniFil Bond, and FL Bond) and one self-etching adhesive(Prompt L-Pop). Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of 50 extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of five adhesives and composite resins: Prompt L-Pop/Filtek Z 250(Group 1), Clearfil SE Bond/Clearfil AP-X(Group 2), Clearfil Liner Bond 2/Clearfil AP-X(Group 3), UniFil Bond/UniFil F(Group 4), and FL Bond/Filtek Z 250(Group 5). Following one day storage in room temperature water, the restored teeth were thermocycled for 500 cycles between 5$^{\circ}C$ and 55$^{\circ}C$. Marginal microleakage was assessed by dye penetration using 2% methylene blue dye. After 24 hours, the teeth were sectioned longitudinally and evaluated for microleakage under steromicroscope The data were statistically analysed by Kruskal-Wallis Test, Mann-Whitney and Wilcoxon signed ranked tests. The results of this study were as follows ; 1. The microleakges at both enamel and dentinal mal$.$gins were the lowest in group 4. increasing among groups in the following order: group 2, follwed by group 5, follwed by group 1, and the highest in group 3. 2. At the enamel margins, the microleakage of group 3 was significantly higher than those of groups 2. 4 and 5(p<0.05), and also the microleakage of group 1 was statistically higher than those of groups 2 and 5(p<0.05). 3. At the dentinal margins, microleakage of group 3 was signincantly higher than microleakages of groups 1, 2, 4 and 5(p<0.05). 4. Compared with microleakages between the enamel and dentinal margins of each group, groups 1, 4 and 5 at enamel margin and group 2 and group 3 at dentinal margin were higher microleakage. But there was no significant difference between enamel and dentinal microleakages of each group(p>0.05).

Comparison of microleakage after load cycling for nanofilled composite resin fillings with or without flowable resin lining (Nanofilled 복합레진으로 와동 충전 시 flowable 레진 사용 유무에 따른 피로시험 후의 미세 변연 누출 비교)

  • Han, Sun-Deok;Kim, Won;Choi, Ji-Young;Oh, Nam-Sik;Lee, Myung-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.342-347
    • /
    • 2009
  • Statement of problem: when using resin for class II restoration, micoleakage by instrumentation can be regarded as the primary negative characteristic. A review of the available literature suggests that using flowable resin as liner to decreased microleakage. Purpose: The aim of this study was to determine the influence of the nanofilled flowable resin lining on marginal microleakage after load cycling in class II composite restoration fillings using nanofiller resin. Material and methods: 24 extracted premolars were prepared with class II cavity. F group was restored the nanofilled resin with the nanofilled flowable resin as liner. NF group was restored the nanofilled resin only. After restoration, an experiment was performed on 2 groups using a 300N load at 104, 105 and 106 cycles. Prior to and before each load cycling, it was gauged length on total marginal microleakage, axial marginal microleakage and buccal, gingival, lingual marginal microleakage. Data were analyzed with the Mann-Whitney test & Kruskal-Wallis test. Results: There were statistically significant differences between 2 groups and between individual groups. (P <.05) The result showed less microleakage in teeth restored by the nanofilled resin, which was lined by the nanofilled flowable resin. Conclusion: There was significant reduction in microleakage when the nanofilled flowable resin lining was placed underneath the nanofilled resin in class II composite restoration fillings.

MARGINAL MICROLEAKAGE OF SINGLE STEP ADHESIVES (단일 단계 접착제의 변연 미세누출)

  • Cho, Young-Gon;Jeong, Jin-Ho;Ki, Young-Jae;Choi, Hee-Young;Jin, Cheul-Hee;Yoo, Sang-Hoon;Kim, Jong-Uk;Park, Byung-Cheul
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.2
    • /
    • pp.162-169
    • /
    • 2004
  • This study evaluated the marginal microleakage of five single step adhesives. Class V cavity preparations with occlusal margins in enamel and gingival margins in dentin were prepared on both buccal and lingual surfaces of extracted human molar teeth. Prepared teeth were randomly divided into five groups and restored using one of the single step adhesives and composite resins:Prompt L-Pop/Filtek Z-250 (Group 1), AQ Bond/Metafil CX (Group 2), One-Up Bond F/Palfique Toughwell (Group 3). Futurabond/Admira (Group 4), Xeno III/Spectrum TPH (Group 5). The restored teeth were thermocycled. Microleakage was assessed by dye penetration using 2% methylene blue dye solution. The teeth were bisected buccolingually and evaluated for microleakage under steromicroscope. The data were statistically analysed by Kruskal-Wallis test and Mann-Whitney tests. The results of this study were as follows:1. Microleakage of enamel margins in group 3 was statistically higher than that in groups 1, 2, 4, 5 (p < 0.05). 2. Microleakage of dentin margins in group 1 was statistically higher than that in groups 2, 5, and that in group 3 was statistically higher than that in groups 2, 4, 5 (p < 0.05). 3. Dentin marginal microleakage was higher than enamel marginal microleakage in all experimental groups. In conclusion, Prompt L-Pop showed the least leakage at enamel margin, and AQ Bond showed at dentin margin in this study. Marginal miroleakage in dentin was higher than that in enamel.

EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS (삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향)

  • Kim, Yong-Hee;Park, Jae-Gu;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.4
    • /
    • pp.327-334
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of burs on microleakage of Class V resin restorations when a self-etching primer adhesive was used. Forty Class V cavities were prepared with four different cutting burs on extracted third molars, and divided into one of four equal groups (n = 10); Group 1-plain cut carbide bur (no. 245), Group 2-cross cut carbide bur (no. 557), Group 3-fine diamond bur (TF-21F), Group 4-standard diamond bur (EX-41). The occlusal and gingival margin of cavities was located in enamel and dentin, respectively. Cavities were treated with Clearfil SE Bond and restored with Clearfil AP-X. Specimens were thermocycled, immersed in a 2% methylene blue solution for 24 hours, and bisected longitudinally. They were observed leakages at enamel and dentinal margins. Data were analyzed using Mann-Whitney and Wilcoxon signed ranked test. The results of this study were as follows; 1. At enamel margin, microleakage of group 4 was statistically higher than those of group 1, 2 and 3 (p < 0.01). 2. At dentinal margin, microleakage of group 4 was statistically higher than group 3 (p < 0.01), but group 1 and 2 were not statistically different with group 3 and 4. 3. Enamel microleakage was statistically higher than dentinal microleakage in group 1, 2 and 3 (p < 0.05), but statistical difference between the microleakage of enamel and dentinal margin was not in Group 4. In conclusion, the use of coarse diamond bur showed high microleakage at both enamel and dentinal margin when Clearfil SE Bond was used in class V cavity.

COMPARATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS TEMPORARY SEALING MATERIALS (근관와동 가봉재 종류에 따른 변연누출의 비교 분석)

  • Yun, Chang;Hong, Suck-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.151-157
    • /
    • 1991
  • The roles of temporary sealing materials used in endodontics are impotant Especially, its marginal sealing properties affect endodontic success and failure in endodontic treatment The purpose of this in vitro study was to compare and evaluate the marginal sealing properties of various temporary restorative materials used in endodontic access cavity by using electrochemical method. Standard endodontic access cavities were prepared in extracted human molar teeth and filled with Caviton, IRM, zinc oxide - eugenol cement. Each specimen was immersed in 1 % solution of KCl, and applied a potential of 9 V external power supply. Marginal microleakage and water sorption were measured for marginal sealing effect evaluation in comparison with each group. A comparative study of the obtained results have led to the following conclusions. 1. The Caviton group showed lower marginal microleakage value than the zinc oxide - eugenol cement and IRM group the 6 th day after. The IRM group showed lwoer marginal microleakage value than the zinc oxide - eugenol cement group from the 6 th day to the 12 th day. But there was no significant difference between zinc oxide - eugenol cement and IRM group after the 13 th day. 2. As time went by, marginal microleakage value was increased in Caviton, IRM and zine oxide - eugenol cement.

  • PDF

QUANTITATIVE ANALYSIS OF MARGINAL MICROLEAKAGE IN VARIOUS RETROGRADE FILLING MATERIALS AND PREPARATION TYPES (역행충전시 수복재와 와동 형태에 따른 변연누출의 정량적 분석)

  • Han, Chung-Kyeung;Yang, Hong-So
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.97-105
    • /
    • 1990
  • When conventional root canal treatment is failed or contraindicated, retrograde root canal filling following apicoectomy is a valuable procedure, aimed at hermetically sealing the root canal against leakage of irritants from the canal into the periapical tissue. In this in vitro investigation, to analyze apical microleakage electrochemically in teeth with different retrograde filling materials and preparation types, single - rooted tooth was cut 2mm from the apex and each Class I and Slot preparation was prepared. Experimental groups : Group 1. Amalgam filling with cavity varnish in Class I preparation Group 2. Scotchbond 2+Silux filling in Class I preparation Group 3. Gutta percha filling with ZOE cement in Class I preparation Group 4. Amalgam filling with cavity varnish in Slot preparation Group 5. Scotchbond 2+Silux filling in Slot preparation Each specimens was immersed in 1% solution of KCl, and applied a potential of 9V external power supply. Measurements of the current flow were obtained at 1, 2, 3, 7, 9, 12, 14, 18, 21, 25 and 28 day after immerson. Marginal microleakage were compared and evaluated. The results were as follows ; 1. The group filled with composite resin with dentin bonding agent shows lower apical microleakage value than the group filled with amalgam following varnish application (P<0.01). 2. In the group filled with gutta percha, apical microleakage value was the hightest 3. There was no significant difference between Class I cavity and Slot type cavity regardless of the used materials.

  • PDF

MICROLEAKAGE OF COMPOSITE RESINS POLYMERIZED WITH ARGON LASER AND VISIBLE LIGHT (가시광선과 아르곤 레이저로 복합레진 중합시 미세누출에 관한 비교 연구)

  • Jang, Ki-Taeg;Chung, Tae-Ryun;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.4
    • /
    • pp.899-905
    • /
    • 1996
  • For the purpose of evaluation of microleakage of class V resin restoration, 64 extracted bovine teeth were filled with two kinds of light curing composite resins(Z-100, Clearfil) and polymerized with 40 seconds of visible light and with 10 seconds of argon laser. After 1000 thermocycling($5^{\circ}C/55^{\circ}C$), specimens were placed in 1 % methylen blue dye solution for 72 hours in $37^{\circ}C$ water bath. The specimens were sectioned at center of filling body and the degree of dye penetration was observed with a stereomicroscope. The following results were obtained, 1. Differences of the microleakage of resin restorations polymerized with 10 seconds of argon laser and 40 seconds of visible light were statistically insignificant. 2. There was more microleakage in Z-100 than clearfil and there was a statistical significancy (p<0.05).

  • PDF

AN AUTORADIOGRAPHIC STUDY OF THE MICROLEAKAGE AROUND A PIT AND FIGURE SEALANT (치면열구 전쇄재의 미세누출에 관한 자가방사법적 연구)

  • Sohn, Jang-Sook;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.10 no.1
    • /
    • pp.77-83
    • /
    • 1983
  • The purpose of this study was to observe the microleakage of a pit and fissure sealant at the tooth-restoration interface. One hundred and sixty-seven extracted permanent and deciduous teeth were used and some simple mechanical pretreatment were done before etching. The degree of microleakage was assessed by $Ca^{45}$ after 24 hours, and 2 months. The results were as follows: 1. Among total 167 teeth, 53 teeth (32%) were demonstrated the microleakage. 2. After 2 months the leakage was increased from 22 percent to 35 percent in permanent teeth, and from 32 percent to 43 percent in primary teeth. 3. The group treated by fluoride paste was demonstrated the largest leakage, 50 percent in primary teeth and 33 percent in permanent teeth. There are more leakage in primary teeth (38%) than permanent teeth (28%).

  • PDF