• Title/Summary/Keyword: microbalance

Search Result 186, Processing Time 0.028 seconds

Quartz Crystal Microbalance Modified by a Novel Vapor Diffused Molecular Assembly Technique and Measurement of Chiral Mandelic Acid (기상확산 자기조립화법에 QCM수식과 Madelic Acid 키랄물질 측정)

  • Kim, JongMin;Kim, SeungJin;Woo, SunYoung;Jang, SukHee;Kim, Woo-Sik;Chang, SangMok
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.574-582
    • /
    • 2010
  • In this study, the possibility of a quartz crystal micro-balance(QCM) modification of crystallization of L-Penicillamine and D-Penicillamine with a Vapor Diffused Molecular Assembly Technique and its application to the R-(-)-Mandelic acid and S-(+)- Mandelic acid measurement was investigated. The 3-dimensional structures of L-Penicillamine and D-Penicillamine on the surface of QCM were verified to be different from each other through QCM and AFM analyses. The D-Penicillamine modified QCM had specific recognition to the R-(-)-Mandelic acid, but L-Penicillamine modified QCM had no specificity to the R-(-)-Mandelic acid and S-(+)- Mandelic acid. From these results, it was known that the QCM could be modified with various selective meterials via VDMA, and the chiral isomer such as a Mandelic acid isomer could be detected by using a modified QCM.

The Electrochemical Characteristics of Mercapto Compounds on the Copper Electroplating (전기구리도금에 미치는 Mercapto화합물의 전기화학적 특성)

  • Son Sang Ki;Lee Yoo Yong;Cho Byung Won;Lee Jae Bong;Lee Tae Hee
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.4
    • /
    • pp.160-165
    • /
    • 2001
  • The eletrochemical charateristics of mercapto compound additives on the copper electroplating for semi conductor metalization were investigated. Mercapto compounds including sulfur atom is known that they activate deposition rate in eletroplating. Four different types of mercapto compounds were chosen with different concentration and both the characteristics of plating and throwing power were investigated by electrochemical experiments such as Hull cell test, Haring-Blum cell, cathodic polarization, EQCM(Electrochemical Quartz Crystal Microbalance). 3-Mercapto-1-propanesulfonic acid among 4 different mercapto compounds was regarded as the most proper activator with the results of the mass change of Cu metal deposited on eletrode by cathodic polarization and EQCM. The overpotential was more shifted to 100 mV in the concentration of 20 ppm than the solution with only $Cl^-$ in cathodic scan.

Development of Olfactory Biosensor Using Olfactory Receptor Proteins Expressed in E. coli

  • Seong, Jong-Hwan;Go, Hwi-Jin;Park, Tae-Hyeon
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.639-642
    • /
    • 2003
  • Olfactory receptor protein ODR10 was expressed in E.coli as fusion protein with GST and His6 Tag. Crude membrane extract of the expressed protein was coated on the surface of quartz crystal microbalance, and the interaction of the ODR10 with several odorants was examined. Although the expression level was very low, quartz crystal microbalance showed that the expressed protein interacted most strongly with diacetyl (butanedione), which is known to bind to the ODR10 protein selectively. The interaction between ODR10 and diacetyl was $5{\sim}10$ times stronger than the interaction between ODR10 and other odorants. Thus, E. coli cells expressing the olfactory receptor protein could be used as an olfactory biosensor. Also, such system could be used to test which olfactory receptor reacts specifically with which odorant molecules, since there has been no cheap and convenient way to test the interaction of olfactory receptors and odorant molecules yet.

  • PDF

Ultrasound-Aided Monolayer Assembly of Spherical Silica Nanobeads (초음파 방법을 이용한 실리카 나노비드의 단층 정렬에 관한 연구)

  • Yoon, Sang-Hee;Yoon, Seo Young;Lee, Jin Seok
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.6
    • /
    • pp.298-305
    • /
    • 2013
  • Uniform silica nanobeads were synthesized by St$\ddot{o}$ber method and assembled in the form of monolayer on glass substrate using sonication method. Before the assembly of silica nanobeads, glass substrates were treated with molecular linkers, such as CP-TMS and PEI, and nanobeads were dispersed in toluene. In attachment test, SO (sonication without stacking) method and SS (sonnication with stacking) method was used and sonication time was controled. After the experiment, microbalance was use to measure deviation between before and after the attachment experiment then calculate percent of coverage. Minutely observe with SEM (Scanning Electron Microscopy) then select the most close-packed and monolayer assembled cover glass and calculate DOC (Degree of Coverage). In SO method, DOC increased very sharply and reach over 140 percent point, also got lots of multi-layer region. On the other hand, in SS method DOC increased slower than SO method but more close-packed and monolayer assembled.

Rapid Detection of Salmonella spp. by Antibody-Immobilized Piezoelectric Crystal Biosensor (고정화법을 달리하여 제조한 압전류적 항체 센서에 의한 Salmonella spp.의 신속 검출)

  • 박인선;김우연;김남수
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.206-212
    • /
    • 1998
  • An improved antibody-coated sensor system based on quartz crystal microbalance was developed for the detection of Salmonella spp. An antibody against Salmonella common structural antigen was immobilized onto one gold electrode of the piezoelectric quartz crystal surface by various immobilization procedures. The best results in sensitivity and stability were obtained with the thin layers of protein A and 3,3'-dithiopropionimidate.2HCI(DTBP), a homobifunctional thiol-cleavable crosslinker. After the addition of a S. typhimurium suspension into a reaction cell with 0.1 M sodium phosphate buffer, pH 7.2, the resonant frequency owing to S. typhimurium adsorption decreased conspicuously. The antibody-immobilized crystals prepared by the gold-protein A complex formation and DTBP thiolation showed the frequency shifts of 80 and 283 Hz, respectively. The time required for maximum frequency shift was about 30~60 min. The antibody-coated crystal could be reused for 6~8 consecutive assays.

  • PDF

Effects of Promoter on the Formation of Gas Hydrate from Blast Furnace Gas (철강공정 배기가스로부터 가스 하이드레이트 형성에 미치는 촉진제의 영향)

  • Kwak, Gye-Hoon;Sa, Jeong-Hoon;Kim, Si-Hwan;Lee, Bo Ram;Lee, Kun-Hong
    • Korean Chemical Engineering Research
    • /
    • v.53 no.1
    • /
    • pp.103-110
    • /
    • 2015
  • In this work, the performance of various promoters was investigated used in $CO_2$ separation from the gases emitted from steel-making process using gas hydrate technology. The studied promoters are tetrahydrofuran (THF), propylene oxide and 1,4-dioxane, which are all expected to form a structure II hydrate, and the target gases include $CO_2/N_2$ mixed gases ($CO_2/N_2$ = 20/80 and 40/60) and Blast Furnace Gas (BFG). The phase equilibrium points were measured when each promoter was added with various concentrations. For fast acquisition of abundant data, the "continuous" Quartz crystal microbalance (QCM) method was employed. In addition, the crystal structure of each gas hydrate was analyzed by Powder X-ray diffraction (PXRD).

A New Concept for Efficient Sensitivity Amplification of a QCM Based Immunosensor for TNF-α by Using Modified Magnetic Particles under Applied Magnetic Field

  • Bahk, Yeon-Kyoung;Kim, Hyung-Hoon;Park, Deog-Su;Chang, Seung-Cheol;Go, Jeung-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.12
    • /
    • pp.4215-4220
    • /
    • 2011
  • This study introduces a new concept for a simple, efficient and cheap sensitivity amplification of a Quartz Crystal Microbalance (QCM) based immunosensor system for the detection of tumor necrosis factor-alpha (TNF-${\alpha}$, TNF) by using an in-built magnetic system. The frequency shift due to the applied magnetic field was successfully observed on magnetic particles labeled detection antibodies, anti-human TNF-${\alpha}$, which were bound to the immunologically captured TNF-${\alpha}$ on the gold coated quartz crystals. In the present system, the magnitude of frequency shift depends on both the strength of magnetic field and the amount of target antigen applied. Significant signal amplification was observed when the additional built-in residual stress generated by the modified magnetic particles under the magnetic field applied. Used in conjunction with a sandwich type non-competitive immunoassay format, the lower detection limit was calculated to be 25 $ngmL^{-1}$ and showed good linearity up to TNF-${\alpha}$ concentrations as high as 2.0 ${\mu}gmL^{-1}$. The sensitivity, most importantly, was improved up to 4.3 times compared with the same QCM system which was used only an antigen-antibody binding without additional magnetic amplification.

Fabrication of an Alternating Multilayer Film of Poly(ethylene-alt-maleic anhydride) and Poly(4-vinyl pyridine) by Layer-by-Layer Self-Assembly Method (Layer-by-Layer 자기조립법에 의한 Poly(ethyiene-alt-maleic anhydride)i Poly(4-vinyl pyrtdine) 다층막 제조)

  • Lee Joon Youl;Hong Sook-Young
    • Polymer(Korea)
    • /
    • v.29 no.4
    • /
    • pp.392-398
    • /
    • 2005
  • Self-assembled multilayer thin films of poly(ethylene-alt-maleic anhydride) (PEMAh) and poly(4-vinyl pyridine) (P4VP) were fabricated by layer-by-layer (LbL) sequential adsorption. Fourier transform infrared (FT-IR) spectroscopic analysis of the self-assembled PEMAh/P4VP multilayer films confirms that the driving forces for the multilayer buildup are the intermolecular hydrogen bonding and electrostatic interactions. The linear increase of absorption peak of P4VP at 256 nm with increasing number of PEMAh/P4VP bilayers indicates that the multilayer buildup is an uniform assembling process. We also investigate the effects of polyelectrolyte concenhation variation of the dipping solution and pH variation of the PEMAh solution on the multilayer film formation. Thickness. adsorbed polyelectrolyte mass and surface roughness of the multilayer films were measured by UV-visible spectroscopy, quartz crystal microbalance (QCM), and atomic force microscopy (AFM), respectively.

Imprinted Graphene-Starch Nanocomposite Matrix-Anchored EQCM Platform for Highly Selective Sensing of Epinephrine

  • Srivastava, Juhi;Kushwaha, Archana;Singh, Meenakshi
    • Nano
    • /
    • v.13 no.11
    • /
    • pp.1850131.1-1850131.19
    • /
    • 2018
  • In this paper, an electrochemical sensor for epinephrine (EP), a neurotransmitter was developed by anchoring molecularly imprinted polymeric matrix (MIP) on the surface of gold-coated quartz crystal electrode of electrochemical quartz crystal microbalance (EQCM) using starch nanoparticles (Starch NP) - reduced graphene oxide (RGO) nanocomposite as polymeric format for the first time. Use of EP in therapeutic treatment requires proper dose and route of administration. Proper follow-up of neurological disorders and timely diagnosis of them has been found to depend on EP level. The MIP sensor was developed by electrodeposition of starch NP-RGO composite on EQCM electrode in presence of template EP. As the imprinted sites are located on the surface, high specific surface area enables good accessibility and high binding affinity to template molecule. Differential pulse voltammetry (DPV) and piezoelectrogravimmetry were used for monitoring binding/release, rebinding of template to imprinted cavities. MIP-coated EQCM electrode were characterized by contact angle measurements, AFM images, piezoelectric responses including viscoelasticity of imprinted films, and other voltammetric measurements including direct (DPV) and indirect (using a redox probe) measurements. Selectivity was assessed by imprinting factor (IF) as high as 3.26 (DPV) and 3.88 (EQCM). Sensor was rigorously checked for selectivity in presence of other structurally close analogues, real matrix (blood plasma), reproducibility, repeatability, etc. Under optimized conditions, the EQCM-MIP sensor showed linear dynamic ranges ($1-10{\mu}M$). The limit of detection 40 ppb (DPV) and 290 ppb (EQCM) was achieved without any cross reactivity and matrix effect indicating high sensitivity and selectivity for EP. Hence, an eco-friendly MIP-sensor with high sensitivity and good selectivity was fabricated which could be applied in "real" matrices in a facile manner.

In-situ Deposition Rate Measurement System to Improve the Accuracy of the Film Formation Process (성막 공정 정밀도 향상을 위한 실시간 성막 속도 측정 시스템)

  • Somi Park;Seung-Yo Baek;Hyun-Bin Kim;Jonghee Lee;Jae-Hyun Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.4
    • /
    • pp.383-387
    • /
    • 2023
  • The quartz crystal microbalance (QCM), commonly used in high vacuum deposition, becomes difficult to use when a thick film is deposited on the quartz, affecting the crystal's inherent vibration. In this study, a non-destructive optical measurement method was developed to measure the film's deposition rate during the in-situ film deposition process. By measuring the scattered laser intensity caused by the dimer in the parylene gas passing through the gas flow path, it was successfully confirmed that the ratio of the dimer in the parylene gas increases as the pyrolysis temperature decreases. Additionally, it was noted that the film's thickness and haze increase as the pyrolysis temperature decreases by confirming the characteristics of the visible parylene films. Through the research results, we aim to utilize the stable in-situ film deposition rate measurement system to control the precise film deposition rate of parylene films.