• Title/Summary/Keyword: method of lines

Search Result 3,180, Processing Time 0.026 seconds

An Effective Installation Method of Lightning Protective Devices for Information and Communication Facilities (정보통신설비에 대한 뇌서지 보호소자의 효과적인 설치기법)

  • Lee, B.H.;Kang, S.M.;Eom, J.H.;Lee, D.M.;Lee, S.B.;Jeong, D.C.;Ahn, C.H.;Jeon, D.K.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1754-1756
    • /
    • 2002
  • This paper deals with an effective installation method of lightning protective devices for information and communication facilities. Due to the potential difference between grounding of the AC power lines and communication lines, the equipments connected to the communication lines are easily damaged by lightning surges. So we have examined the behaviors of surge protective devices against lightning surges from the AC power lines and signal lines, and the coordination effects of SPD installation method were investigated. As a result, it was confirmed that the bypass arrester method and common grounding method were very effected.

  • PDF

Determination of plates with inflection lines for hull plate forming (곡가공을 위한 변곡 곡면의 판정)

  • Kim, Chan Suk;Shin, Jong Gye
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.5
    • /
    • pp.365-371
    • /
    • 2015
  • Hull plate consists of various types of curved plates and there also exists corresponding processing methods. Typically, curved plates can be divided into convex type and saddle type. Large amount of research has been conducted mainly focusing on application of processing method of convex type, saddle type and hybrid type, but research on determination and processing method application of the most difficult S-shaped curved plate that has inflection lines has not been carried out yet. In this paper, as the fundamental research of appropriate processing method application, a calculation method is proposed to calculate inflection lines on curved plates. In order to calculate inflection lines, normal curvature and information of fabricated curved plates should be utilized. We compare the workability of the fabrication for hull plate using inflection line.

A Method for Generation of Contour lines and 3D Modeling using Depth Sensor (깊이 센서를 이용한 등고선 레이어 생성 및 모델링 방법)

  • Jung, Hunjo;Lee, Dongeun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.1
    • /
    • pp.27-33
    • /
    • 2016
  • In this study we propose a method for 3D landform reconstruction and object modeling method by generating contour lines on the map using a depth sensor which abstracts characteristics of geological layers from the depth map. Unlike the common visual camera, the depth-sensor is not affected by the intensity of illumination, and therefore a more robust contour and object can be extracted. The algorithm suggested in this paper first abstracts the characteristics of each geological layer from the depth map image and rearranges it into the proper order, then creates contour lines using the Bezier curve. Using the created contour lines, 3D images are reconstructed through rendering by mapping RGB images of the visual camera. Experimental results show that the proposed method using depth sensor can reconstruct contour map and 3D modeling in real-time. The generation of the contours with depth data is more efficient and economical in terms of the quality and accuracy.

Quantitative Analysis of Two Genetically Modified Maize Lines by Real-Time PCR

  • Lee Seong-Hun;Kang Sang-Ho;Park Yong-Hwan;Min Dong-Myung;Kim Young-Mi
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.2
    • /
    • pp.205-211
    • /
    • 2006
  • A quantitative analytical method to detect new lines of genetically modified (GM) maize, NK603 and TC1507, has been developed by using a real-time polymerase chain reaction (PCR). To detect these GM lines, two specific primer pairs and probes were designed. A plasmid as a reference molecule was constructed from an endogenous DNA sequence of maize, a universal sequence of a cauliflower mosaic virus (CaMV) 35S promoter used in most GMOs, and each DNA sequence specific to the NK603 and TC1507 lines. For the validation of this method, the test samples of 0, 0.1, 0.5, 1.0, 3.0, 5.0, and 10.0% each of the NK603 and TC1507 GM maize were quantitated. At the 3.0% level, the biases (mean vs. true value) for the NK603 and TC1507 lines were 3.3% and 15.7%, respectively, and their relative standard deviations were 7.2% and 5.5%, respectively. These results indicate that the PCR method developed in this study can be used to quantitatively detect the NK603 and TC1507 lines of GM maize.

A Reassessment for Dynamic Line Rating of Aged Overhead Transmission Lines in Kepco's Network (한국전력 노후 가공송전선의 동적송전용량에 대한 재평가)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.123-129
    • /
    • 2010
  • During the past 2 decades, many electric power companies have been searching various solutions in order to supply power with economical and more efficiency in the present transmission utilities. Most interesting method to increase the line capacity of overhead transmission lines without constructing any new line might be to adapt Dynamic Line Rating(DLR). Specified rating is normally determined by any current level, not by conductor temperature. Although specified rating is essential to design transmission line, dip may be the most important factor in limiting transmission capacity. Transmission lines built by the oldest dip criterion among the 3 different design criteria for conductor dip are nearly over one-half of all Kepco's transmission lines. This paper describes an up-rating method for those transmission lines in order to apply DLR technique. Based on limit dip conductor temperature and current of the transmission lines, limitation performance and effectiveness in applying DLR with weather model are analyzed. As a result of analysis, it can be shown that an improved method could be effectively used for increasing the line rating of old transmission line which was built by the design criterion with low dip margin.

Development of an Extraction Method of Cortical Surfaces from MR Images for Improvement in Efficiency and Accuracy (효율성과 정확도 향상을 위한 MR 영상에서의 뇌 외곽선 추출 기법 개발)

  • An, Kwang-Ok;Jung, Hyun-Kyo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.4
    • /
    • pp.549-555
    • /
    • 2007
  • In order to study cortical properties in human, it is necessary to obtain an accurate and explicit representation of the cortical surface in individual subjects. Among many approaches, surface-based method that reconstructs a 3-D model from contour lines on cross-section images is widely used. In general, however, medical brain imaging has some problems such as the complexity of the images, non-linear gain artifacts and so on. Due these limitations, therefore, extracting anatomical structures from imaging data is very a complicated and time-consuming task. In this paper, we present an improved method for extracting contour lines of cortical surface from magnetic resonance images that simplifies procedures of a conventional method. The conventional method obtains contour lines through thinning and chain code process. On the other hand, the proposed method can extract contour lines from comparison between boundary data and labeling image without supplementary processes. The usefulness of the proposed method has been verified using brain image.

A Comparative Study on Distortion Correction Algorithms for Digital Cadastral Maps (전산화 지적도의 왜곡 최소화 알고리즘 비교연구)

  • 김병국;정동훈;김해명
    • Spatial Information Research
    • /
    • v.11 no.4
    • /
    • pp.421-437
    • /
    • 2003
  • In order to calculate the position of parcel boundary points, the area of the Parcel, and the length of the parcel boundary lines using a digitalized cadastral map or maps, the distortion of the map has to be corrected. The correction methods, such as the method of 2D affine transformation using 4 comer points of the edge lines, the method of tessellation into 9 subregions, the method of using the original surveying sheets, and the method of straightening the 4 edge lines, have been developed. In this Paper, the four methods were programed and applied to some sample cadastral maps and the correction accuracies were obtained and analysed. No method could prefectly correct the distortions because the distortions were irregular throughout the maps. However, it is found that tile method of straightening the 4 edge lines is the one which can minimize the distortions when the method is applied after applying the 2D projective transformation on the maps using the 4 comer points of the edges.

  • PDF

Meshless equilibrium on line method (MELM) for linear elasticity

  • Sadeghirad, A.;Mohammadi, S.;Kani, I. Mahmoudzadeh
    • Structural Engineering and Mechanics
    • /
    • v.35 no.4
    • /
    • pp.511-533
    • /
    • 2010
  • As a truly meshfree method, meshless equilibrium on line method (MELM), for 2D elasticity problems is presented. In MELM, the problem domain is represented by a set of distributed nodes, and equilibrium is satisfied on lines for any node within this domain. In contrary to conventional meshfree methods, test domains are lines in this method, and all integrals can be easily evaluated over straight lines along x and y directions. Proposed weak formulation has the same concept as the equilibrium on line method which was previously used by the authors for enforcement of the Neumann boundary conditions in the strong-form meshless methods. In this paper, the idea of the equilibrium on line method is developed to use as the weak forms of the governing equations at inner nodes of the problem domain. The moving least squares (MLS) approximation is used to interpolate solution variables in this paper. Numerical studies have shown that this method is simple to implement, while leading to accurate results.

Crosstalk Analysis of Bent Coupled Lines on a PCB (PCB상에 놓여 있는 굽은 결합 선로의 누화 해석)

  • Han, Jae-Kwon;Park, Dong-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.191-198
    • /
    • 2007
  • The electromagnetic coupling between transmission lines in PCB design can degrade the performance of equipment operations. The coupling phenomenon is caused by electromagnetic fields generated by the currents on the transmission lines and the risers. In this paper, an improved method of crosstalk analysis for bent coupled lines on a PCB is proposed and investigated. In the previous cascading method combined with circuit-concept approach, bent coupled lines are devided into sections and each section is represented by ABCD matrix and then they are cascaded. In the proposed method, the crosstalk of bent coupled lines is calculated by the modified circuit-concept approach, where the coupled region is not restricted to the region projected by a generator line on a receptor line but is the total length of receptor line in calculating the forcing terms. Finally, the accuracy of the proposed approach is verified by comparing the calculated results with the measured ones for several bent coupled-line examples.

Theoretical and Experimental Analysis of Extremely Low Frequency Magnetic Field in the Vicinity of the Transformer Station of Overhead Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali;Bizid, Youssef
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1655-1662
    • /
    • 2018
  • This paper studies the magnetic fields between the power lines which are finite length and other ones which are infinitely long around the first tower in the proximity of the power transformers. They will be used as a source of disturbance applied to the power line. The method applied in this study was gradual; develop the theoretical formulation of the magnetic fields of these lines which are finite length and other ones which are infinitely long, examine the effects of different couplings between the different neighboring lines and the distribution transformers on behavior of magnetic fields. The method also focused on the experimental results analyzing the magnetic fields which will be used as a source applied to the auditory implants EMC. The theoretical and experimental results were compared and discussed for three power lines (90kV, 150kV and 225kV) near the power station, and it proved the effect of these substations on the simulated and measured results of the magnetic field. The maximum intensities of magnetic fields measured at the height of 1m from the ground for the circuit of three lines close to each substation were significantly lower than the ICNIRP reference levels for occupational and non occupational exposures.