• Title/Summary/Keyword: mechanical output

Search Result 1,635, Processing Time 0.034 seconds

Integrated Cavity Output Spectroscopy Using an External Cavity Diode Laser for the Density Absorption Measurement of Trace Gases (미량 기체의 밀도 측정을 위한 외부 공진기 반도체 레이저 광학공동 적분 투과 분광법)

  • Ryoo Hoon Chul;Yoo Yong Shin;Lee Jae Yong;Hahn Jae Won
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.24-30
    • /
    • 2006
  • Integrated cavity output spectroscopy(ICOS) is a simple, non-intrusive absorption measurement technique that can detect and quantify trace-level gas species. The spectral absorbance of a gas is quantified from the integrated optical output of the modulated high-finesse cavity containing the sample which is irradiated by a wavelength-swept laser source. We constructed an experimental setup by using a tunable single mode external cavity diode laser operating at the wavelength near 765 nm and a Fabry-Perot cavity with length modulation achieved by a piezoelectric transducer where one of the cavity mirrors sat on. In the experiment performed on minute oxygen gas at the wave-length near 764.5nm, we demonstrated the minimum detectable absorption of $8.45\times10^{-8}cm^{-1}$.

A Fault Isolation Filter Design Using Left Eigenstructure Assignment Scheme

  • Choi, Jae-Weon;Lee, Shi-Bok;Lee, Dae-Young;Park, Un-Sik;Suh, Young-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.583-589
    • /
    • 2000
  • This paper presents a novel fault isolation filter design method using left eigenstructure assignment scheme proposed by the first author et al. The proposed method shows good performance of fault isolation with an exact eigenstructure assignment and guarantees that the corrupted ${\gamma}$ faults can be isolated simultaneously when the number of available output measurements are equal to or larger than (${\gamma}+1$). A numerical example for the fault isolation filter is also included.

  • PDF

Improved Power Output by a Piezoelectric Cantilever after Addition of a Cylindrical Bar (원통 봉을 적용한 압전 캔틸레버의 성능 향상)

  • Lee, Youngjin;Kim, Seiki;Kim, Young-Deuk
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.5
    • /
    • pp.516-521
    • /
    • 2014
  • This paper describes the development of a new piezoelectric unimorph cantilever structure intended to improve electrical output power, compared to a conventional cantilever. The proposed structure employs a cylindrical bar attached to one side of a steel plate, which is a significant factor in forced vibration mode. The feasibility of the proposed methodology was assessed experimentally and theoretically. The influence of three different types of bar material (i.e., stainless steel, silicon rubber, and urethane), and bar position, on the output voltage were examined and compared with those without the bar. The optimal position and material for the bar were identified through experimental and theoretical analyses. It appears that the electrical output power of the proposed cantilever is about 40% higher than that of a conventional unimorph cantilever.

Characteristics on the Output Coupled Type CVT Combined Differential Gear Unit (차동기어장치를 적용한 출력축 연결방식 무단변속기의 특성해석에 관한 연구)

  • Choi, Sang-Hoon;Kim, Yeon-Su
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.3
    • /
    • pp.205-215
    • /
    • 2001
  • Continuously variable transmission(CVT) mechanisms considered here combine the functions of a 2K-H I type differential gear unit and a V-belt continuously variable unit(CVU). One shaft of the V-belt CVU is connected directly to the differential gear unit and remaining shaft of it is linked to the output shaft. These mechanisms have many advantage which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral. In this paper six different mechanisms of output coupled type CVT are proposed. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed, and theoretical analysis are proven by various experiments.

  • PDF

Sliding Mode Control of Rotational Inverted Pendulums Using Output Feedback Compensator (출력 피드백을 이용한 회전형 역진자의 슬라이딩 모드 제어)

  • Ha, Jong-Heon;Choi, Joeng-Ju;Kim, Jong-Shik
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.469-474
    • /
    • 2000
  • A sliding mode control method using the parameterization of both the hyperplane and the compensator for output feedback and reduced observer is presented for rotational inverted pendulums. This control strategy overcomes the problem of unattainable velocity state which is resulted from severe noise of analogue sense and constructs numerical algorithms designs of dynamic output feedback sliding mode hyperplane and controller. The result of the experiment shows the superior performance compared with the LQ controller and the robustness with respect to both tapping disturbances and certain initial conditions.

  • PDF

Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL) (PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어)

  • Choi, S.W.;Shim, E.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

Study of a Durability Test for Single-input Multi-output Power Take-off Gearboxes (단일입력 다출력 PTO 기어박스의 내구성시험에 관한 연구)

  • Lee, Yong Bum;Yoo, Han Ju
    • Journal of Drive and Control
    • /
    • v.14 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • This study analyzed a life test method for a power take-off (PTO) gearbox. An engine transfers mechanical power (rotation and torque) to a hydraulic pump through a PTO Gearbox with one input shaft and three output shafts. PTO gear box durability under high loads over long time periods was tested using dynamometers. In order to reflect the rated operating conditions, power must be distributed to each output shaft, and experiments were conducted under various conditions to verify the characteristics of the distributed power. An accelerated life test was designed using speed and torque as acceleration factors. Also, efficiency tests were conducted under various load conditions. Also, a lubrication oil composition analysis was performed to analyze gearbox wear status.

Blind modal identification of output-only non-proportionally-damped structures by time-frequency complex independent component analysis

  • Nagarajaiah, Satish;Yang, Yongchao
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.81-97
    • /
    • 2015
  • Recently, a new output-only modal identification method based on time-frequency independent component analysis (ICA) has been developed by the authors and shown to be useful for even highly-damped structures. In many cases, it is of interest to identify the complex modes of structures with non-proportional damping. This study extends the time-frequency ICA based method to a complex ICA formulation for output-only modal identification of non-proportionally-damped structures. The connection is established between complex ICA model and the complex-valued modal expansion with sparse time-frequency representation, thereby blindly separating the measured structural responses into the complex mode matrix and complex-valued modal responses. Numerical simulation on a non-proportionally-damped system, laboratory experiment on a highly-damped three-story frame, and a real-world highly-damped base-isolated structure identification example demonstrate the capability of the time-frequency complex ICA method for identification of structures with complex modes in a straightforward and efficient manner.

Calibration of Strain Gauge for Thermal Expansion Coefficientof Fiber Reinforced Composites at Cryogenic Temperature (극저온 환경에서의 섬유강화 복합재료의 열팽창 계수 측정을 위한스트레인 게이지의 보정에 관한 연구)

  • Lee, Won-Oh;Lee, Sang-Bok;Yi, Jin-Woo;Um, Moon-Kwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.12 no.3
    • /
    • pp.1-6
    • /
    • 2010
  • Since the fiber reinforced polymeric (FRP) composites are considered in next generation of space transportation systems, reliable thermal expansion properties should be well provided for structural design of composite materials. To obtain accurate mechanical behaviors at a cryogenic temperature, precise strain measurement and calibration must be provided. In this work, apparent strains (or thermal output) of temperature self-compensated strain gages were deliberately investigated for epoxy, CTBN modified epoxy and carbon fabric composite system from room temperature to liquid nitrogen temperature. Also, fourth-order thermal output curves were presented for the further calibration. The results showed that the thermal output is heavily dependent on test materials and a large amount of apparent strains were observed for the polymer resins.

Computing of output of piezoelectric actuator under voltage excitation

  • Yongfeng Fang;Kong Fah Tee;Yong Yan
    • Smart Structures and Systems
    • /
    • v.33 no.5
    • /
    • pp.359-364
    • /
    • 2024
  • It is difficult to calculate the output force of a single-layer piezoelectric actuator under voltage excitation. In this paper, the piezoelectric actuator is organically combined with the mass-spring-damping system, and the deformation of the piezoelectric actuator under voltage excitation is transformed into the displacement of the mass-spring-damping system. Then, according to the differential equation of the system, the formulae of the mechanical output of the piezoelectric actuator under sinusoidal alternating current and DC step excitation are obtained by using the Laplace change and the inverse change, respectively. Finally, the proposed equations are verified by using ceramic piezoelectric actuators and PVDF actuators, respectively. The results are compared with the existing ones, which shows that the proposed method is feasible, easy, and practical.