• 제목/요약/키워드: mechanical device

검색결과 2,854건 처리시간 0.023초

고속 공기압 실린더 내장용 쿠션기구의 특성 비교 (Characteristic Comparison on Internal Cushion Devices at High-speed Pneumatic Cylinders)

  • 김도태;장중걸
    • 한국자동차공학회논문집
    • /
    • 제21권6호
    • /
    • pp.24-30
    • /
    • 2013
  • This paper studies the comparative analysis on two different internal cushion devices (the types of needle and relief valve) used to absorb the energy which is generated when the pneumatic cylinder moves with the load at meter-out speed control system. The effect at varying the piston velocity under same driving condition is mainly investigated. The simulation results on pressure in the cushion chamber and the dynamic behavior of the relief valve type cushion device are compared with the needle valve type. Design and performance are improved with the cushion configuration of better quality at high-speed pneumatic cylinder. Based on the relation between absorbed energy and impact energy at cushion process, cushion performance at pneumatic cylinder is evaluated.

공기스프링 방진대의 능동제어 (Active Control of Air-Spring Vibration Isolator)

  • 송진호;김규용;박영필
    • 대한기계학회논문집
    • /
    • 제18권7호
    • /
    • pp.1605-1617
    • /
    • 1994
  • Air-spring is widely used in vibration isolation to reduce the table vibration. When a disturbance is applied to a table, however, it starts virbrating with a low frequency, but has a large displacement due to the reacting force of air-spring. In this study, to solve the table vibration problem, an active vibration control device based on state feedback control using air-spring and proportional control valves was designed. This device can suppress the displacement of the isolation table within allowable range, even any kind of disturbances are applied to the table. Firstly, theoretical analysis of an air-spring isolator was done. Secondly, characteristics of the isolator was investigated via computer simulation and experiment. Finally, active control of air-spring isolator was tested using optimal(LQG) and fuzzy control algorithms was performed to show the effectiveness of the control schems.

유체기구를 이용한 유압계통의 충격치제어에 수탄되는 반응지연에 관한 연구 (A Study on the Associated Response Lag in Shock Control of Hydraulic System Using Fluid Device)

  • 이주성;이계복
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1488-1495
    • /
    • 2002
  • The response time represents how fast a system responds to a given disturbance at the system boundary. Flow restricting devices for controlling transients can result in a decrease in the peakm pressure, but may change response time. Response lag in a hydraulic system leads to inefficient working cycle and operator discomfort. The experiments were conducted in order to get information on the parameters which exert appreciable influence on the response time. The experimental apparatu including a hydraulic actuator, orifice and a hydraulic pump was an idealization of a bucket hydraulic shifting system. Experimental results show that the response time depends on operating pressure and flow rate. The effects of orifice type and size on the response time are quantified.

미세유체소자를 이용한 간단하고 효율적인 액적의 병합 (Simple and Highly Efficient Droplet Merging Method Using a Microfluidic Device)

  • 진병주;김영원;유정열
    • 대한기계학회논문집B
    • /
    • 제33권3호
    • /
    • pp.178-185
    • /
    • 2009
  • Simple and highly efficient droplet merging method is proposed, which enables two nanoliter or picoliter droplets to merge regularly in a straight microchannel. Using a cross channel with inflows of one oil phase through the main channel and two water phases through the side channels, two droplets of different sizes can be generated alternatingly in accordance with flow rate difference of the water phases. It is shown that for a fixed oil phase flow rate, the flow rate of one water phase required for alternating droplet generation increases linearly with the flow rate of another water phase. By this method, the droplets are merged with 100 % efficiency without any additional driving forces.

Cutter blade에 의한 SUS 및 지르칼로이 튜브 절단 실험 (Experiment on Cutting the SUS and Zircaloy Tubes by Cutter Blade)

  • 정재후;윤지섭;홍동희;김영환;박기용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.651-654
    • /
    • 2001
  • In the dismantling process of nuclear spent fuels, the spent fuel rod cutting process, followed immediately by the decladding process, performs the cutting the spent fuel rods to a proper length for fast decladding operation. In this paper, we analyzed the chemical compositions, mechanical properties, and physical characteristics for SUS and zircaloy tubes in order to identify the feasibility of cutter-blade type in cutting SUS and zircaloy tubes. It is considered that material, shape and angle, and heat treatment for fabricating the highly durable cutter blade and also it is investigated that the round-shape sustenance of cross-section, amount of debris production, and fire occurrence for measuring the cutting performance on SUS and zircaloy tubes, spent fuel rod cutting device is designed to be operated automatically through the remote control system for use in Hot Cell(radioactive) area and the electro-driven mechanical parts are modularized for easy maintenance. Results from various experiments confirm the efficiency of this device.

  • PDF

구리 CMP시 슬러리 Flow Rate의 조절 (Control of Slurry Flow Rate in Copper CMP)

  • 김태건;김남훈;김상용;서용진;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.34-37
    • /
    • 2004
  • Recently advancing mobile communication tools and I.T industry, semiconductor device is requested more integrated, faster operation time and more scaled-down. Because of these reasons semiconductor device is requested multilayer interconnection. For the multilayer interconnection chemical mechanical polishing (CMP) becomes one of the most useful process in semiconductor manufacturing process. In this experiment, we focus on understand the characterize and improve the CMP technology by control of slurry flow rate. Consequently, we obtain that optimal flow rate of slurry is 170ml/min, since optimal conditions are less chemical flow and performance high with good selectivity to Ta. If we apply this results to copper CMP process. it is thought that we will be able to obtain better yield.

  • PDF

Fabrication and Characterization of Thermally Actuated Bimorph Probe for Living Cell Measurements with Experimental and Numerical Analysis

  • Cho Young-Hak;Kang Beom-Joon;Hong Seok-Kwan;Kang Jeong-Jin
    • Journal of Mechanical Science and Technology
    • /
    • 제20권3호
    • /
    • pp.297-309
    • /
    • 2006
  • This paper deals with a novel structure for single-cell characterization which makes use of bimorph micro thermal actuators combined with electrical sensor device and integrated microfluidic channel. The goal for this device is to capture and characterize individual biocell. Quantitative and qualitative characteristics of bimorph thermal actuator were analyzed with finite element analysis methods. Furthermore, optimization for the dimension of cantilevers and integrated parallel probe systems with microfluidic channels is able to be realized through the virtual simulation for actuation and the practical fabrication of prototype of probes. The experimental value of probe deflection was in accordance with the simulated one.

머신비젼을 이용한 구멍 정밀도의 기상측정시스템 개발 (On-Machine Measurement System Development of Hole Accuracy using Machine Vision)

  • 김민호;김태영
    • 한국정밀공학회지
    • /
    • 제27권5호
    • /
    • pp.7-13
    • /
    • 2010
  • The integrity and accuracy of the drilling hole are decided by positional error, diameter error, the roundness, the straightness, the cylindericity, size of the burr, the surface roundness and others. Among these parameters, positional error and diameter error have the most important parameters. The diameter error has been widely studied, but there has been little research done about the positional error due to the difficulty of measuring it. The measurement of hole location and diameter would be performed by CMM(Coordinate Measurement Machine). However, the usage of CMM requires much time and cost. In order to overcome the difficulties, we have developed a hole location and diameter error measuring device using machine vision. The developed measurement device attached to a CNC machine can determine hole quality quickly and easily.

열 대류 가속도계의 성능향상에 관한 연구 (A Study on the Performance Improvement of the Micromachined Convective Accelerometer)

  • 윤성기;오준석
    • 대한기계학회논문집A
    • /
    • 제31권5호
    • /
    • pp.570-577
    • /
    • 2007
  • A micromachined convective accelerometer is a recently developed device. Typical micromachined accelerometers use a solid proof mass for measuring acceleration. But a micromachined convective accelerometer does not use a solid proof mass. A micromachined convective accelerometer is composed of a heating resistor and temperature sensors. This device measures acceleration by using convective heat transfer phenomenon. Therefore characteristics of a micromachined convective accelerometer are different as compared with typical micromachined accelerometer. In this research, we analyze the convective accelerometer by using transient convective heat transfer analysis. Based on the results of a convective accelerometer, we propose a new model which has improved performance.

Multi-Channel Vibrotactile Display for Teleoperated Assembly

  • Thomas Debus;Jang, Tae-Jeong;Pierre Dupont;Robert Howe
    • International Journal of Control, Automation, and Systems
    • /
    • 제2권3호
    • /
    • pp.390-397
    • /
    • 2004
  • This paper presents the design and testing of a multi-channel vibrotactile display. It is composed of a cylindrical handle with four embedded vibrating elements driven by piezoelectric beams. Vibrations are transmitted to the hands through arrays of pins. The device was tested in sensory substitution for conveying force information during a teleoperated peg insertion. Results show that the device is effective in reducing peak forces during the insertion task.