• Title/Summary/Keyword: mechanical device

Search Result 2,854, Processing Time 0.03 seconds

Hydrogen production with high temperature solar heat thermochemical cycle using NiFe2O4/m-ZrO2 device (NiFe2O4/m-ZrO2 device를 이용한 고온 태양열 열화학 싸이클의 수소 생산)

  • Lee, Jin-Gyu;Shin, Il-Yoong;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.107-114
    • /
    • 2011
  • Two-step thermochemical cycle using ferrite-oxide($Fe_3O_4$) device was investigated. The $H_2O$(g) was converted into $H_2$ in the first experiment which was performed using a dish type solar thermal system. However the experiment was lasted only for 2 cycles because the metal oxide device was sintered and broken down. Another problem was that the reaction was taken place mainly on a side of the metal oxide device. The $m-ZrO_2$, which was widely known as a material preventing sintering, was applied on the metal oxide device. The ferrite loading rate and the thickness of the metal oxide device were increased from 10.67wt% to 20wt% and from 10mm to 15mm, respectively. The chemical reactor having two inlets was designed in order to supply the reactants uniformly to the metal oxide device. The second-experiment was lasted for 5 cycles, which was for 6 hours. The total amount of the $H_2$ production was 861.30mL.

Improvement of surgical haptic master device using cable-conduit and backlash compensation by smooth backlash inverse (케이블 컨듀잇 구조의 수술용 햅틱 마스터 장치의 개선과 smooth backlash inverse를 이용한 backlash 보정)

  • Choi, Woo Hyeok;Yoon, Sung Min;Lee, Min Cheol
    • The Journal of Korea Robotics Society
    • /
    • v.9 no.1
    • /
    • pp.48-56
    • /
    • 2014
  • In robotic surgery, a surgeon checks only a surgical site of patient in the progress of surgery by vision and sound information. In order to solve this limited information, the haptic function is necessary. And haptic surgical robot is also necessary to design a haptic master device. The master device for laparoscope operation with cable-conduit was developed in previous research to give haptic function. It suggested a possibility of developing a master device by using the cable-conduit. However, it is very inconvenient to use. Therefore, this paper suggests a new mechanism design structure to solve the problems of the previous work by new forming a new master device. And it has proved that it's usability is better than previous one. Furthermore it has also experimented and analyzed that a backlash of new master device is compensated by smooth backlash inverse algorithm.

Least Squares Method-Based System Identification for a 2-Axes Gimbal Structure Loading Device (2축 짐벌 구조 적재 장치를 위한 최소제곱법 기반 시스템 식별)

  • Sim, Yeri;Jin, Sangrok
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.3
    • /
    • pp.288-295
    • /
    • 2022
  • This study shows a system identification method of a balancing loading device for a stair climbing delivery robot. The balancing loading device is designed as a 2-axes gimbal structure and is interpreted as two independent pendulum structures for simplifying. The loading device's properties such as mass, moment of inertia, and position of the center of gravity are changeable for luggage. The system identification process of the loading device is required, and the controller should be optimized for the system in real-time. In this study, the system identification method is based on least squares method to estimate the unknown parameters of the loading device's dynamic equation. It estimates the unknown parameters by calculating them that minimize the error function between the real system's motion and the estimated system's motion. This study improves the accuracy of parameter estimation using a null space solution. The null space solution can produce the correct parameters by adjusting the parameter's relative sizes. The proposed system identification method is verified by the simulation to determine how close the estimated unknown parameters are to the real parameters.

Development of Hybrid Fused Deposition Modeling System for Three-Dimensional Circuit Device Fabrication (3 차원 회로 장치 제작을 위한 FDM 기반의 통합 시스템 개발)

  • O, Sung Taek;Lee, In Hwan;Kim, Ho-Chan;Cho, Hae Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.869-874
    • /
    • 2014
  • It is possible to fabricate a three-dimensional (3D) shape using the solid freeform fabrication (SFF) technology. However, there are several problems in applying conventional SFF technologies to the direct manufacturing of a product. Hence, multimaterial SFF is gaining attention. Moreover, a 3D circuit device that is different from a conventional two-dimensional PCB can also be fabricated using multimaterial SFF. In this study, a hybrid system using fused deposition modeling and direct writing was designed for 3D circuit device fabrication.

Roller Design of IRB Seismic Isolation Device Using Testing Evaluation : Part I. Geometry Dimension and Crowning (시험평가법을 이용한 IRB 면진장치 롤러 설계 : Part 1. 기하학적 형상 및 크라우닝)

  • Park, Young-Gee;Ha, Sung Hoon;Seong, Min-Sang;Jeon, Junchul;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.2
    • /
    • pp.185-191
    • /
    • 2013
  • This paper presents a new method for roller design of IRB(isolation roller bearing) seismic isolation device using experimental evaluation. Three layered plate is adopted for the IRB in which the upper plate is placed on x direction and the lower plate is placed on y direction. The rollers placed in each plate make a plate movement. The roller is then optimally designed using variable geometric conditions. Stress distribution depends on the diameter and length of the roller and hence this is used for the determination of optimal geometry of the roller. In the experimental evaluation, it is observed that stress concentration at the end sides of roller is decreased and geometric coefficients depend on crowning dimension. In addition, in order to determine optimal design parameters of the roller the plastic deformation and friction are experimentally identified.

Wafer-Level Packaged MEMS Resonators with a Highly Vacuum-Sensitive Quality Factor

  • Kang, Seok Jin;Moon, Young Soon;Son, Won Ho;Choi, Sie Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.5
    • /
    • pp.632-639
    • /
    • 2014
  • Mechanical stress and the vacuum level are the two main factors dominating the quality factor of a resonator operated in the vacuum range 1 mTorr to 10 Torr. This means that if the quality factor of a resonator is very insensitive to the mechanical stress in the vacuum range, it is sensitive to mainly the ambient vacuum level. In this paper, a wafer-level packaged MEMS resonator with a highly vacuum-sensitive quality factor is presented. The proposed device is characterized by a package with out-of-plane symmetry and a suspending structure with only a single anchor. Out-of-plane symmetry helps prevent deformation of the packaged device due to thermal mismatch, and a single-clamped structure facilitates constraint-free displacement. As a result, the proposed device is very insensitive to mechanical stress and is sensitive to mainly the ambient vacuum level. The average quality factors of the devices packaged under pressures of 50, 100, and 200 mTorr were 4987, 3415, and 2127, respectively. The results demonstrated the high controllability of the quality factor by vacuum adjustment. The mechanical robustness of the quality factor was confirmed by comparing the quality factors before and after high-temperature storage. Furthermore, through more than 50 days of monitoring, the stability of the quality factor was also certified.

Roller Design of IRB Seismic Isolation Device Using Test Evaluation : Part II. Heat Treatment of Material (시험평가법을 이용한 IRB 면진장치 롤러 설계 : Part 2. 소재 열처리)

  • Park, Young-Gee;Ha, Sung Hoon;Seong, Min-Sang;Jeon, Junchul;Choi, Seung-Bok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.332-337
    • /
    • 2013
  • This paper presents a subsequent research work on the roller design of IRB(isolation roller bearing) seismic isolation device presented in Part 1 by focusing on heat treatment. The hardness and friction factor are very important factors of material and after-treatment process selection. Normally, roller bearing consists of roller and retainer. The roller gets high pressure constantly, while the retainer gets tensile and compressive stress. Therefore, sensitive material selection and heat treatment of each part is quite important. In this experimental evaluation, carbon steel, chrome special steel and others are employed and their characteristics after heat treatment are identified. Each material is prepared by refining high frequency heat treatment. The friction factor and static load capacity of manufactured material are experimentally identified and destructive test of material is processed. Optimal material and heat treatment conditions for IRB roller bearing are determined based on experiment results.

Development of a Half-Duplex Communication Device for Use via Human Skin (인체 임피던스를 이용한 양방향 통신 시스템의 설계)

  • Kim, Won-Jun;Song, Kyo-Yong;Kim, Young-Pil;Ko, Dong-Young;Kim, Jung-Han
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.5
    • /
    • pp.583-587
    • /
    • 2015
  • In this study, a half-duplex mutual communication device via human skin was developed. Frequency-shift keying (FSK) digital modulation and demodulation control were used to transmit and receive data. Data communication through the human body is an effective communication technique and has high-grade security characteristics. In addition, making contact is a natural instinct of humans. Transmitting data through the human body is currently a highly conspicuous technology, because recently a lot of commercial sensors for humans have been developed. A body area network (BAN) can be easily constructed by this communication method on human skin. In this study, a half-duplex FSK mutual communication device was developed using a commercial FSK modulator and demodulator. A special control switching circuit and communication sequence were developed for mutual communication through human skin.

A STUDY ON THE DESIGN OF SIMPLE RECORDING DEVICE TO TRACE THE MANDIBULAR MOVEMENTS (하악골운동 추적을 위한 단순기록장치 고안에 관한 연구)

  • Kim, Sang-Soo;Yoon, Chang-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.25 no.1
    • /
    • pp.253-267
    • /
    • 1987
  • The purpose of this study was to improve limitations and disadvantages of the mechanical pantograph and the Visi-Trainer, and to design the reliable and reproducible device mandibular movement tracking device (MMTD) that is more simple, convenient and save the chair time than the mechanical pantograph and Visi-Trainer. MMTD was consist of head frame, horizontal bar, condylar path tracking stylus holders, anterior path tracking stylus holder, two condylar path plastic recording plates, one anterior path plastic recording plate, toggles and open occlusal clutch. To prove the reliability and reproducibility of MMTD, a five adults were selected and mandibular condylar movement was recorded one time by the mechanical pantographic tracing and MMTD. The border movement recording of the mandibular incisor (frontal, sagittal and horizontal) was also recorded by Visi-Trainer and the MMTD. The obtained results were as follows; 1. The condylar movement path (sagittal, horizontal) of the MMTD was not coincidence with that of mechanical pantograph. 2. Measurements of the angulation which established between working and balancing path records by use of the mechanical pantograph and MMTD, there was no significance. 3. In a view of MMTD's reproducibility, there was revealed almost similar recording pattern. 4. The border movement recording of the mandibular incisor by the MMTD and the Visi-Trainer showed almost same reliability and reproducibility. 5. The subjects were able to his original mandibular movements by use of open occlusal clutch in the MMTD.

  • PDF

Treatment of pulmonary thromboembolism using Arrow-Trerotola percutaneous thrombolytic device

  • Kim, Tae Kyun;Park, Ji Young;Bae, Jun Ho;Choi, Jae Woong;Ryu, Sung Kee;Kim, Min-Jung;Kim, Jun Bong;Sohn, Jang Won
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.1
    • /
    • pp.28-32
    • /
    • 2014
  • Pulmonary thromboembolism (PTE) increases the pressure of the right ventricle and leads to symptoms and signs, such as dyspnea and hypoxia. If PTE causes hemodynamic instability, thrombolytic therapy should be considered. A mechanical thrombectomy is an alternative treatment to thrombolytic therapy and should be considered when thrombolytic therapy is contraindicated. Various devices are used in mechanical maceration and catheter-directed thrombolysis, but there is no standard mechanical device for PTE as yet. We report here on 2 clinical experiences of mechanical thrombectomy using the Arrow-Trerotola percutaneous thrombolytic device to remove residual clots after systemic thrombolysis in patients with massive PTE.