• Title/Summary/Keyword: measurement point

Search Result 3,223, Processing Time 0.037 seconds

Measurement of Rock Slope Joint using 3D Image Processing (3차원 영상처리를 이용한 암반 사면의 절리 측정에 관한 연구)

  • Lee, Seung-Ho;Hwang, Jeong-Cheol;Sim, Seok-Rae;Jeong, Tae-Young
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.854-861
    • /
    • 2005
  • Studied accuracy and practical use possibility of joint measurement that using 3D laser scanner to rock slope. Measured joint of Rock slope and comparison applied 3 dimension laser scanner and clinometer. 3D laser scanning system preserves on computer calculating to 3 dimension coordinate scaning laser to object. and according to laser measurement method of interior, produce correct vector value from charge-coupled device(CCD) or laser reciver and telegram register and time measuring equipment. Create of object x, y, z point coordinates to 3 dimension space of computer. Such 3 dimension point datum (Point Clouds) forms relocate position informations that exist to practical space to computer space. Practical numerical values related between each other. Compared joint distribution and direction that measured by laser scanner and clinometer. By the result, Distribution of joint projected almost equally. Could get more joint datas by measurement of 3 dimension scanner than measured by clinometer. Therefore, There is effect that objectification of rock slope investigation data, shortening of investigation periods, investigation reduction of cost. could know that it is very effective method in joint measuring.

  • PDF

Development of Posture Evaluation System through Digital Recognition Method (디지털 영상인식 방법을 통한 자세평가 및 운동가동범위 측정시스템 개발)

  • Moon, Young-Jin;Lee, Soon-Ho;Back, Jin-Ho;Lee, Jong-Gak;Lee, Gun-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.49-65
    • /
    • 2004
  • The purpose of this study is development of posture evaluation and Range of Motion(ROM) system by using digital vision analysis method. The results of this study are as follows. First, Scoliosis evaluation through this research measurement system represent 3mm error in 7 cervical point and deepest lumbar point, 0.7mm error in other point. This mean this research measurement system have a reliability for scoliosis evaluation. Second, for spine line evaluation on high fat subject, we need reconstrection spine line after measurement for fat thickness in 7 cervical point and deepest lumbar point. Third, In pedioscope error test, it present 0.01848cm in X axis and 0.01757cm in Y axis. This results mean pedioscope have a reliability foot evaluation. Forth, Posture evaluation and Range of Motion measurement system by using digital vision analysis method can fast measure in range of motion and foot evaluation and posture. therefore we can expect this system application in young people posture clinic center and hospital and so on.

Development of Multi-point Heat Flux Measurement for Steel Quenching (강재 열처리용 다점 열유속 측정 기술 개발)

  • Lee, Jungho;Oh, Dong-Wook;Do, Kyu Hyung;Kim, Tae Hoon
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.25 no.4
    • /
    • pp.181-189
    • /
    • 2012
  • The demand on quantitative measurement of the heat flux is motivated in making higher-quality steel product through a water quenching process of plate mill. To improve a spatial degree of heat flux measurement, the multi-point heat flux measurement was carried out by a unique experimental technique that has a combination of the existing single-point heat flux gauge. The corresponding heat flux can be easily determined by Fourier's law in a conventional way. The multi-point heat flux gauge developed in this study can be applicable to measure the surface heat flux, the surface heat transfer coefficient during a water quenching applications of steelmaking process. The results exhibit different heat transfer regimes; such as single-phase forced convection, nucleate boiling, and film boiling, that are occurred in close proximity on the multi-point heat flux gauge quenched by water impinging jet.

A Study on the Introduction of Speed Enforcement System Using Point-to-point Speed Measurement (구간방식 과속단속장치 도입방안에 관한 연구)

  • Lee, Sang-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.3 s.81
    • /
    • pp.88-97
    • /
    • 2007
  • A point based speed enforcement system(SES) has been widely used in roadways to reduce the operating speeds and potential traffic accidents. Recently, the needs for introudcing new SES using point-to-point speed measurement was presented, however, no practical guidelines or justification of the system was available. This study investigated the effectiveness of the current SES and introduction of the new SES through user interview survey method. Survey results showed that 33% of respondents were unsatisfactory to the current way of SES operation, which was 11% higher than satisfactory respondents, and about 70% of the respondents supported the introduction of point-to-point based SES operation. A majority of respondents preferred the straight roadway segment, bridge and tunnel, and curved roadway segment for a start application site with the segment length of 1-5 km long. Using these survey results, an introduction scheme was discussed in terms of legal bases, installation criteria, and operational guidelines.

Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes (다점 피토관을 이용한 기체 유량 측정의 불확도 평가)

  • Yang, Inyoung;Lee, Bo-Hwa
    • The KSFM Journal of Fluid Machinery
    • /
    • v.19 no.2
    • /
    • pp.5-10
    • /
    • 2016
  • Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.

Upper Body Somatotypes of the Left-Handed and the Right-Handed - Focusing on male and female collegians in their 20s - (왼손 및 오른손 사용자(使用者)의 상반신체형(上半身體型)에 관한 비교연구(比較硏究) - 20대(代) 남녀(男女) 대학생(大學生)을 중심(中心)으로 -)

  • Shim, Boo-Ja
    • Journal of Fashion Business
    • /
    • v.7 no.4
    • /
    • pp.78-92
    • /
    • 2003
  • The upper-body characteristics of the right-handed and the left-handed are examined and compared through 1-dimensional measurement and 2-dimensional measurement. The results were as follows: 1. According to 1-dimensional measurement results, the clearest differences were seen in girth items rather than height or length items. In particular, hand girth, lower arm girth, and upper arm girth were bigger on the left side in the left-handed group and the right side in the right-handed group. This is thought to be relevant to the arm muscles frequently used. 2. According to 2-dimensional measurement results, significant differences appeared in the females of the left-handed group: shoulder point among width items. In the right-handed group, some differences of significance were shown in females (shoulder point, rear armpit point, and B.P. point among width items) and males (front neck point among extreme vertical distance items). In summary, the body type characteristics of the left-handed and the right-handed reveal great differences in the items related to arm length and arm girth. In other words, the sleeve and shoulder patterns production based on the right-handed don't rightly reflect the somatotype characteristics of the left-handed. In addition, in the cases of athletes, laborers, and the disabled who frequently use particular muscles or parts of the body, this sort of research in the patterns is consistently needed in order to reflect the size differences in girth items in upper body.

A Study on Improvement of Method for Measuring the Shield Performance of Shielding Enclosures (전자파 차폐실의 차폐효과 측정방법 개선에 관한 연구)

  • Yeon, Jae-Sung;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.350-353
    • /
    • 2009
  • The shielding enclosure is very essential device to test the electromagnetic wave power generated by various RF equipments. Some standards for the shielding enclosures were established to test them in right method. Generally, There are IEEE-STD-299 and MIL-STD-285 and NSA-65-6 of the method for measuring the effectiveness of shielding enclosures, the IEEE-STD-299 combined MIL-STD-285 and NSA-65-6 about the method for measuring shielding effectiveness(SE) about 1969 years, but, the measurement point of 299 proposal is many points(including shielding wall, seam, coner beat, shielding door, etc) and demand long time of measurement. To improve SE test method for shielding enclosures was studied and suggested to develop a proper test procedure. First, we measure reference level as frequency range and H/V polarization, secondly, measure leakage point, and finally, measure shield effect and calculate SE. Our method has a merit of the less measurement point than IEEE-STD-299, and shorten time than 299, and define representation SE of shielding enclosure effectively.

  • PDF

The Merging Method of Point Data with Point Pattern Matching in 3D Measurement (3차원 형상측정에서 점 패턴매칭을 이용한 점 데이터의 결합방법)

  • 조택동;이호영;양상민
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.714-719
    • /
    • 2003
  • We propose a measuring method of large object using the pattern matching. It is hard and expensive to get the complete 3D data when the object is large and exceeds the limit of measuring devices. The large object is divided into several smaller areas and is scanned several times to get the data of all the pieces. These data are aligned to get the complete 3D data using the pattern matching method such as point pattern matching method and transform matrix algorithm. The laser slit beam and CCD camera are applied for the experimental measurement. Visual C++ on Windows 98 is implemented in processing the algorithm.

The Measurement and Application of the Minimum Detectable Irradiance for the Infrared Point Source Detection System (적외선 점광원 탐지장비의 최소탐지조도 측정 및 활용)

  • Kim, Hyun-Sook;Yang, Yu-Kyung;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.58-63
    • /
    • 2011
  • A procedure and method for the MDI(Minimum Detectable Irradiance) measurement of an infrared point source detection system is described in detail and its experimental result is analyzed. The proposed measurement method for MDI can be realized with a collimator in the laboratory environment. In addition, an estimation method of the maximum detection range of the infrared point source detection system is introduced and its performed result is shown.

Measurement and Computing Method of the Average Illuminance in Residential Areas (공동주택의 조도측정 및 평균조도 산출방법)

  • Joo, Keun-Tak;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.1-8
    • /
    • 2006
  • The Five Point Method of KS and Four Point Method of IES are generally used to measure and compute the average illuminance in residential areas. Such methods of measurement should be used exactly according to the characteristics of the space and activities. Therefore, this study evaluated computation methods of the average illuminance in terms of comparing the measured values with simulated ones. The Five Point Method of KS is very closed to evaluate task illuminancefor appreciating activities at the center while the Four Point Method of IES is very closed to a concept of the average illuminance over the space excluding the possible maximum and minimum illuminance values.