Browse > Article
http://dx.doi.org/10.5293/kfma.2016.19.2.005

Uncertainty Assessment of Gas Flow Measurement Using Multi-Point Pitot Tubes  

Yang, Inyoung (Engine system research team, Korea Aerospace Research Institute)
Lee, Bo-Hwa (Engine system research team, Korea Aerospace Research Institute)
Publication Information
Abstract
Gas flow measurement in a closed duct was performed using multi-point Pitot tubes. Measurement uncertainty was assessed for this measurement method. The method was applied for the measurement of air flow into a gas turbine engine in an altitude engine test facility. 46 Pitot tubes, 15 total temperature Kiel probes and 9 static pressure tabs were installed in the engine inlet duct of inner diameter of 264 mm. Five tests were done in an airflow range of 2~10 kg/s. The flow was compressible and the Reynolds numbers were between 450,000 and 2,220,000. The measurement uncertainty was the highest as 6.1% for the lowest flow rate, and lowest as 0.8% for the highest flow rate. This is because the difference between the total and static pressures, which is also related to the flow velocity, becomes almost zero for low flow rate cases. It was found that this measurement method can be used only when the flow velocity is relatively high, e.g., 50 m/s. Static pressure was the most influencing parameter on the flow rate measurement uncertainty. Temperature measurement uncertainty was not very important. Measurement of boundary layer was found to be important for this type of flow rate measurement method. But measurement of flow non-uniformity was not very important provided that the non-uniformity has random behavior in the duct.
Keywords
Gas Flow Measurement; Multi-point Pitot Tubes; Measurement Uncertainty; Boundary Layer;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 ISO, 2008, Measurement of Fluid Flow in Closed Conduits - Velocity Area Method Using Pitot Static Tubes, ISO 3966:2008.
2 Choi, J. C., Lee, K. G., and Park, C. W., 2001, "Development of the Pitot-Tube to Measure Flight Altitude and Velocity," Journal of the Korean Society of Propulsion Engineers, Vol. 5, No. 3, pp. 19-24.
3 Oh, S. Y., Lee, J. G., Kim, S. C., Kim, S. H., and Ahn, S. K., 2012, "An Experimental Study of Test Section Velocity Calibration for Low-Speed Wind Tunnel," Journal of The Korean Society for Aeronautical and Space Sciences, Vol. 40, No. 3, pp. 230-236.   DOI
4 Lim, J. M., 2000, An Experimental Study on the Flow Measurement by Using Multi-point Pitot Tube, Master Thesis, Mokpo National University.
5 Nguyen, D. T., 2013, Evaluation of Uncertainty for Gas Flow Measurement with S Pitot Tube, Master Thesis, University of Science and Technology.
6 Lee, B. H., Lee, K. J., and Yang, S. S., 2010, "The Preduction of Air Flow and Pressure Loss at Inlet Duct," Journal of the Korean Society of Propulsion Engineers, Vol. 14, No. 1, pp. 48-55.
7 ISO/IEC, 2008, Uncertainty of Measurement - Part 3: Guide to the Expression of Uncertainty in Measurement, ISO/IEC Guide 98-3.