• Title/Summary/Keyword: measurement

Search Result 46,876, Processing Time 0.085 seconds

The Analysis of Dose in a Rectum by Multipurpose Brachytherapy Phantom (근접방사선치료용 다목적 팬톰을 이용한 직장 내 선량분석)

  • Huh, Hyun-Do;Kim, Seong-Hoon;Cho, Sam-Ju;Lee, Suk;Shin, Dong-Oh;Kwon, Soo-Il;Kim, Hun-Jung;Kim, Woo-Chul;K. Loh John-J.
    • Radiation Oncology Journal
    • /
    • v.23 no.4
    • /
    • pp.223-229
    • /
    • 2005
  • Purpose: In this work we designed and made MPBP(Multi Purpose Brachytherapy Phantom). The MPBP enables one to reproduce the same patient set-up in MPBP as the treatment of the patient and we tried to get an exact analysis of rectal doses in the phantom without need of in-vivo dosimetry. Materials and Methods: Dose measurements were tried at a point of rectum 1, the reference point of rectum, with a diode detector for 4 patients treated with tandem and ovoid for a brachytherapy of a cervix cancer. Total 20 times of rectal dose measurements were made with 5 times a patient. The set-up variation of the diode detector was analyzed. The same patient set-ups were reproduced in self-made MPBP and then rectal doses were measured with TLD. Results: The measurement results of the diode detector showed that the set-up variation of the diode detector was the maximum $11.25{\pm}0.95mm$ in the y-direction for Patient 1 and the maximum $9.90{\pm}4.50mm,\;20.85{\pm}4.50mm,\;and\;19.15{\pm}3.33mm$ in the z-direction for Patient 2, 3, and 4, respectively. Un analyzing the degree of variation in 3 directions the more variation was showed in the z-direction than x- and y-direction except Patient 1. The results of TLD measurements in MPBP showed the relative maximum error of 8.6% and 7.7% at a point of rectum 1 for Patient 1 and 4, respectively and 1.7% and 1.2% for Patient 2 and 3, respectively. The doses measured at R1 and R2 were higher than those calculated except R point of Patient 2. this can be thought to related to the algorithm of dose calculation, whcih corrects for air and water but is guessed not to consider the correction for the scattered rays, but by considering the self-error (${\pm}5%$) TLD has the relative error of values measured and calculated was analyzed to be in a good agreement within 15%. Conclusion: The reproducibility of dose measurements under the same condition as the treatment could be achieved owing to the self-made MPMP and the dose at the point of interest could be analyzed accurately. If a treatment is peformed after achieving dose optimization using the data obtained in the phantom, dose will be able to be minimized to important organs.

Comparison of Virtual Wedge versus Physical Wedge Affecting on Dose Distribution of Treated Breast and Adjacent Normal Tissue for Tangential Breast Irradiation (유방암의 방사선치료에서 Virtual Wedge와 Physical Wedge사용에 따른 유방선량 및 주변조직선량의 차이)

  • Kim Yeon-Sil;Kim Sung-Whan;Yoon Sel-Chul;Lee Jung-Seok;Son Seok-Hyun;Choi Ihl-Bong
    • Radiation Oncology Journal
    • /
    • v.22 no.3
    • /
    • pp.225-233
    • /
    • 2004
  • Purpose: The Ideal breast irradiation method should provide an optimal dose distribution In the treated breast volume and a minimum scatter dose to the nearby normal tissue. Physical wedges have been used to Improve the dose distribution In the treated breast, but unfortunately Introduce an Increased scatter dose outside the treatment yield, pavllculariy to the contralateral breast. The typical physical wedge (FW) was compared with 4he virtual wedge (VW) to do)ermine the difference In the dose distribution affecting on the treated breast and the contralateral breast, lung, heart and surrounding perlpheral soft tissue. Methods and Materials: The data collected consisted of a measurement taken with solid water, a Humanoid Alderson Rando phantom and patients. The radiation doses at the ipsllateral breast and skin, contralateral breast and skin, surrounding peripheral soft tissue, and Ipsllateral lung and heart were compared using the physical wedge and virtual wedge and the radiation dose distribution and DVH of the treated breast were compared. The beam-on time of each treatment technique was also compared Furthermore, the doses at treated breast skin, contralateral breast skin and skin 1.5 cm away from 4he field margin were also measured using TLD in 7 patients of tangential breast Irradiation and compared the results with phantom measurements. Results: The virtual wedge showed a decreased peripheral dose than those of a typical physical wedge at 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, and 60$^{\circ}$. According to the TLD measurements with 15$^{\circ}$ and 30$^{\circ}$ virtual wedge, the Irradiation dose decreased by 1.35$\%$ and 2.55$\%$ In the contralateral breast and by 0.87$\%$ and 1.9$\%$ In the skin of the contralateral breast respectively. Furthermore, the Irradiation dose decreased by 2.7$\%$ and 6.0$\%$ in the Ipsllateral lung and by 0.96$\%$ and 2.5$\%$ in the heart. The VW fields had lower peripheral doses than those of the PW fields by 1.8$\%$ and 2.33$\%$. However the skin dose Increased by 2.4$\%$ and 4.58$\%$ In the Ipsliateral breast. VW fields, In general, use less monitor units than PW fields and shoriened beam-on time about half of PW. The DVH analysis showed that each delivery technique results In comparable dose distribution in treated breast. Conclusion: A modest dose reduction to the surrounding normal tissue and uniform target homogeneity were observed using the VW technique compare to the PW beam in tangential breast Irradiation The VW field is dosmetrically superlor to the PW beam and can be an efficient method for minimizing acute, late radiation morbidity and reduce 4he linear accelerator loading bV decreasing the radiation delivery time.

A Study of Changes of Pulmonary Artery Size after Bidirectional Cavopulmonary Shunt (양방향성 상대정맥-폐동맥 단락술 후의 폐동맥 크기 변화에 관한 연구)

  • 지현근;이정렬
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.495-503
    • /
    • 1996
  • The bidirectional cavopulmonary shunt may be useful as an intermediate procedure before Fontal oper- ation in high-risk patients, because it provides adequate relief of cyanosis and relief of ventricular volume overload. But there are no established theory about the effects of bidirectional cavopulmonary shunt on pulmonary arterial development. The purpose of this article is a study of changes of pulmonary artery size after bidirectional cavopulmonary shunt. Ca diac catheterization and angiography procedures were done on 19 patients who underwent bidirectional cavopulmonary shunt from February 1992 to July 1994, their results were reviewed. Preoperative cardiac catheterization and angiography procedures were performed at a mean interval of ).8 $\pm$4.8($\pm$SEM) months before surgery and following catheterization at a mean postoperative interval of 19.6 $\pm$4.8 months. Pulmonary arterial sixte measurement were standardized for body surface area(Pulmon- arty artery index), and for diameter of descending thoracic aorta(McGoon ratio). Patient's age, body stir- face area, pulmonary angioplasty, preoperative McGoon ratio and follow-up intervals were considered as variables. Before bidirectional cavopulmonary shunt, patient's mean age, body surface area, arterial 02 saturation, diameter of right pulmonary artery, diameter of left pulmonary artery, pulmonary artery Index, McGoon ratio were 13.7$\pm$15.6 months, 0.40$\pm$0.12m2, 71.4$\pm$12.4m2, 7.1$\pm$1.7mm, 6.2$\pm$1 , 191.8$\pm$82.7mm21m2, 1.73 $\pm$0.49, respectively. After bidirectional cavopulmonary shunt, the values were changed to 39.9 $\pm$ 16.2 months, 0.58$\pm$0.07 m2, 83.0$\pm$3.8m2, 9.0$\pm$ 1.5 mm, 7.7$\pm$2.0, 197.3$\pm$57.1 mm2/m2, 1.76$\pm$0.32, respect- ively With patients'development (age, body surf'ace area), diameters of pulmonary arteries were increased, but pulmonary artery indices and McGoon ratios were not changed. And there were no effects of age, body surf'ace area, amount of increased 02 saturation, pulmonary angiography and follow-up duration on the increment of pulmonary ar- tery size. But when the McGoon ratio was as low as 1.2, there were significant increase in postoperative pulmonary artery sizes. There was a significant correlation between preoperative pulmonary artery index (PAI) and McGoon ratio (MGR) ; PAI : MGRxl18.0-12.4 In conclusion, bidirectional cavopulmonary shunt provides adequate increment of arterial 02 saturation and does not increase the pulmonary artery size. Further investi ation is mandatory to evaluate the effect of pulsatile bidirectional cavopulmonary shunt on pulmonary artery growth.

  • PDF

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

Relationship between Vaginal Cytology and Reproductive Hormone during the Estrous Cycle and Optimal Mating Time in Beagle Dogs (비글개에서 발정 주기 및 교배 적기 동안 질세포상과 번식 호르몬의 관계)

  • Lee K.C.;Kang H.G.;Cheun H.M.;Kim I.H.
    • Journal of Embryo Transfer
    • /
    • v.21 no.2
    • /
    • pp.109-119
    • /
    • 2006
  • This study was conducted to examine relationship between vaginal cytology and reproductive hormones during the estrous cycle and to provide basic data to estimate for ovulation time and optimal mating time in 6 beagle dogs The duration of proestrus, estrus and diestrus were $8.5{\pm}1.4,\;10.0{\pm}1.4\;and\;54.0{\pm}2.8$ days at pregnant respectively, and $7.9{\pm}2.1,\;9.5{\pm}0.7\;and\;62.0{\pm}11.3$ days at non-pregnant respectively. The duration of interestrous intervals were $246.2{\pm}24.5$ days at pregnancy, and $175.3{\pm}34.5$ days at non-pregnancy. The duration of interestrous intervals at pregnancy was longer than that of non-pregnancy. A characteristic features of vaginal cytology during the estrous cycle were the high proportion of superficial cell, anuclear cell and erythrocyte in proestrus and estrus, parabasal cell, small intermediate cell and leukocyte in diestrus, and parabasal cell and small intermediate cell in anestrus, respectively. Cornification index (CI) in proestrus and estrus were significantly higher than that of CI in diestrus and anestrus. Plasma progesterone concentration was below 1.0 ng/ml at the first day of vulval bleeding at pregnancy and non-pregnancy, and then it was above 2.0 ng/ml at Day -2 in all bitches. When plasma progesterone concentration was first increased above 4.0 ng/ml, it was the second day after the first day of male acceptance. Plasma progesterone concentration showed above 40 ng/ml on Day $20{\sim}22$ in all bitches, and then it was gradually decreased until Day 35. Plasma progesterone concentration at pregnancy was higher than that of non-pregnancy from Day 35 to Day 63. Plasma estradiol-$17\;{\beta}$ concentration was above 9.0 pg/ml at the first day of vulval bleeding, and it showed 26.4 pg/ml on Day -2. When it was timed from the first day of male acceptance (Day 0), plasma estradiol-$17{\beta}$ concentration showed a peak on Day 0 and plasma progesterone concentration was first increased above 4.0 ng/ml on Day 2 which was the third day after plasma estradiol-$17{\beta}$ peak. CI was first increased above 80 and 90% on Day -1 and Day 1, respectively. CI was maintained above 80% from Day -1 to Day 8 (10 days) and above 90% from Day 1 to Day 6 (6 days), respectively. CI was maintained above 80% from Day 0 to Day 8 (9 days) and above 90% from Day 1 to Day 6 (6 days), respectively. Plasma progesterone concentration was first increased above 4.0 ng/ml on the second day after the day which CI was first increased above 90%. In conclusion, beagle bitches ovulated on the second day after the day which CI was first increased above 90% and on the day which plasma progesterone concentration was first increased 4.0 ng/ml, and it was estimated that the optimal mating time was the day which the second day after CI was first increased above 90% and plasma concentration was between $2{\sim}25ng/ml$. The measurement of plasma progesterone was used to determine of and accurate ovulation time and the optimal mating time, but vaginal cytology is low-priced and simple method to estimate estrous cycle, optimal mating time and ovulation time.

A Comparative Survey on Misconception and Desire for Physique of College Women in Taegu and Fukuoka (한.일 여대생의 자기 체형 인식 및 체형 불안도에 관한 비교 연구)

  • Hong, Jin-Pyo;Choi, Bong-Soon
    • Journal of the Korean Society of Food Culture
    • /
    • v.15 no.5
    • /
    • pp.435-442
    • /
    • 2000
  • This study was carried out to investigate misconception for physique and desire for physique of college women in Taegu(412 subjects) and Fukuoka(423 subjects). The data was collected by questionnaire interview and anthropometric measurement. The results were as follows : The mean age, height, weight, and BMI of Taegu subjects were $19.9{\pm}1.2$ years old, $159.6{\pm}4.9cm,\;51.2{\pm}6.0kg\;and\;20.1{\pm}2.2$, respectively. The mean age, height , weight, and BMI of Fukuoka subjects were $18.3{\pm}0.6$ year old, $157.5{\pm}5.0cm,\;53.3{\pm}6.9kg\;and\;21.5{\pm}2.5$, respectively. The average ideal height desired by subjects in Taegu was higher than their real mean height by 5.1cm ; while the average ideal weight desired by subjects was lower than real mean weight by 2.6kg. The average ideal height desired by subjects in Fukuoka was higher than their real mean height by 3.2cm ; while the average ideal weight desired by subjects was lower than real mean weight by 5.4kg. The percentage of Taegu subjects who desired to be slender, be fatty and maintain weight were 70.1%, 7.3%, and 22.6% respectively. The percentage of Fukuoka subjects who desired to be slender, be fatty and maintain weight were 85.3%,2.6% and 12.1% respectively. The rate of misconception for the actual physique was 56.5% in Taegu subjects, and 57.2% In fukuoka subjects. The over estimation rate was higher in subjects desired for slenderness than in others. The adolescent females having a fatty body image in self-consciousness indicated that they felt high social physique anxiousness. Finally, the rate of misconception and the degree of social physique anxiousness were higher in those who had a desire for slenderness.

  • PDF

Inhomogeneity correction in on-line dosimetry using transmission dose (투과선량을 이용한 온라인 선량측정에서 불균질조직에 대한 선량 보정)

  • Wu, Hong-Gyun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.139-147
    • /
    • 1998
  • Purpose: Tissue inhomogeneity such as lung affects tumor dose as well as transmission dose in new concept of on-line dosimetry which estimates tumor dose from transmission dose using the new algorithm. This study was carried out to confirm accuracy of correction by tissue density in tumor dose estimation utilizing transmission dose. Methods: Cork phantom (CP, density $0.202\;gm/cm^3$) having similar density with lung parenchyme and polystyrene phantom (PP, density $1.040\;gm/cm^3$) having similar density with soft tissue were used. Dose measurement was carried out under condition simulating human chest. On simulating AP-PA irradiation, PPs with 3 cm thickness were placed above and below CP, which had thickness of 5, 10, and 20 cm. On simulating lateral irradiation, 6 cm thickness of PP was placed between two 10 cm thickness CPs additional 3 cm thick PP was placed to both lateral sides. 4, 6, and 10 MV x-ray were used. Field size was in the range of $3{\times}3$ cm through $20{\times}20$ cm, and phantom-chamber distance (PCD) was 10 to 50 cm. Above result was compared with another sets of data with equivalent thickness of PP which was corrected by density. Result: When transmission dose of PP was compared with equivalent thickness of CP which was corrected with density, the average error was 0.18 (${\pm}0.27$) % for 4 MV, 0.10 (${\pm}0.43$) % for 6 MV, and 0.33 (${\pm}0.30$) % for 10 MV with CP having thickness of 5 cm. When CP was 10 cm thick, the error was 0.23 (${\pm}0.73$) %, 0.05 (${\pm}0.57$) %, and 0.04 (${\pm}0.40$) %, while for 20 cm, error was 0.55 (${\pm}0.36$) %, 0.34 (${\pm}0.27$) %, and 0.34 (${\pm}0.18$) % for corresponding energy. With lateral irradiation model, difference was 1.15 (${\pm}1.86$) %, 0.90 (${\pm}1.43$) %, and 0.86 (${\pm}1.01$) % for corresponding energy. Relatively large difference was found in case of PCD having value of 10 cm. Omitting PCD with 10 cm, the difference was reduced to 0.47 (${\pm}$1.17) %, 0.42 (${\pm}$0.96) %, and 0.55 (${\pm}$0.77) % for corresponding energy. Conclusion When tissue inhomogeneity such as lung is in tract of x-ray beam, tumor dose could be calculated from transmission dose after correction utilizing tissue density.

  • PDF

『황제내경소문(黃帝內經素問)·칠편대론(七篇大論)』 왕빙 주본(注本)을 통(通)한 운기학설(運氣學說) 관(關)한 연구(硏究)

  • Kim, Gi-Uk;Park, Hyeon-Guk
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.4
    • /
    • pp.109-140
    • /
    • 1995
  • As we considered in the main subjects, investigations on the theory of 'Doctrine on five elements' motion and six kinds of natural factors(運氣學說)' through 'Wang Bing's Commentary(王氷 注本)' of 'The seven great chapters in The Yellow Emperor's Internal Classic Su Wen' ("黃帝內經素問 七篇大論") are as follows. (1) In The seven great chapters("七篇大論")' Wang Bing supplement theory and in the academic aspects as a interpreter, judging from 'forget(亡)' character. expressed in the 'The missing chapters("素問遺篇")', 'Bonbyung-ron("本病論")' and 'Jabeob-ron(刺法論)', 'The seven great chapters("七篇大論")' must be supplementary work by Wang Bing. Besides, he quoted such forty books as medical books, taoist books, confucianist books, miscellaneous books, etc in the commentary and the contents quoted in the 'Su Wen(素問)' and 'Ling Shu("靈樞")' scripture nearly occupy in the book. As a method of interpreting scripiure as scripture, he edited the order of 'Internal Classic("內經")' ascended from the ancient time and when he compensated for commentary, with exhaustive scholarly mind and by observing the natural phenomena practically and writing the pathology and the methods of treatment. We knew that the book is combined with the study of 'Doctrine on five elements motion and six kinds of natural factors(運氣學說)' (2) When we compare, analyze the similar phrase of 'The seven great chapters in The Yellow Emperor's Internal Classic Su Wen'("黃帝內經素問ㆍ七篇大論") through 'Wang Bing's Commentary(王氷 注本)', he tells abouts organized 'five elements(五行)' and 'heaven's regularly movement(天道運行)' rather than 'Emyangengsangdae-ron("陰陽應象大論")' in 'The seven great chapters("七篇大論")'. Also the 'Ohanunhangdae-ron("五運行大論")' because the repeated sentences with 'Emyangengsangdae-ron("陰陽應象大論")' is long they are omitted. And in the 'Youkmijidae-ron("六微旨大論")', 'Cheonjin ideology(天眞四象)' based on the 'Sanggocheonjin- ron("上古天眞論")', 'Sagijosindae-ron("四氣調神大論")' is written and in the 'Gigoupyondae-ron("氣交變大論")', the syndrome and symptom are explained in detail rather than 'Janggibeobsi-ron("藏氣法時論")', 'Okgijinjang-ron ("玉機眞藏論")' and in the 'Osangieongdae-ron("五常政大論")', the concept of 'five element(五行)' of the 'Gemgwejineon-ron("金櫃眞言論")' is expanded to 'the five elements' motion concept(五運槪念)' and in the 'Youkwonjeonggidae-ron("六元正紀大論")', explanations of 'The five elements' motion and six kinds of natural factors(運氣)' function are mentioned mainly and instead systematic pathology is not revealed rather than 'Emyangengsangdae-ron("陰陽應象大論")'. And in the 'Jijinyodae-ron("至眞要大論")', explanations of the change of atmosphere which correspond to treatment principle by 'The three Yin and Yang(三陰三陽)' as a progressed concepts are revealed. Therefore there are much similarity between the phrase of 'Emyangengsangdae-ron("陰陽應象大論")' and 'chapters of addition(補缺之篇)'. Generally, the doctrine which 'The seven great chapters("七篇大論")' are added by Wang Bing(王氷) is supported because there are more profound concepts rather than the other chapter in 'The seven great chapters("七篇大論")'. (3) When we study Wang Bing's(王氷) 'Pattern on five elements motion and six kinds of natural factors(運氣格局)' in 'The seven great chapter("七篇大論")', in the 'Cheonwongi-dae-ron("天元紀大論")', With 'Cheonjin ideology(天眞思想)' and the concepts of 'Owang(旺)'${\cdot}$'Sang(相)'${\cdot}$'Sa(死)'${\cdot}$'Su(囚)'${\cdot}$'Hu(休)' and 'Cheonbu(天符)'${\cdot}$'Sehwoi(歲會)' are measured time-spacially to the concept of 'Three Sum(三合)' the concept of 'Taeulcheonbu(太乙天符)' is explained. In the 'Ounhangdae-ron("五運行大論")', 'The calender Signs five Sum(天干五合)' is compared to the concepts of 'couples(夫婦)', 'weak-strong(柔强)' and in the 'Youkmijidae-ron("六微旨大論")', 'the relationship of obedience and disobedience(順逆關係)' which conform to the 'energy status(氣位)' change and 'monarch-minister(君相)' position is mentioned. In the 'Gikyobyeondae-ron("氣交變大論")', the concept of 'Sang-duk(相得)', 'Pyungsang(平常)' is emphasized but concrete measurement is mentioned. In the 'Osangieongdae-ron("五常政大論")', the detailed explanation with twenty three 'systemic of the five elements' motion(五運體系)' form and 'rountine-contrary treatment(正治. 反治)' with 'chill-fever-warm-cold(寒${\cdot}$${\cdot}$${\cdot}$凉)' are mentioned according to the 'analyse and differentiate pathological conditions in accordance with the eight principal syndromes(八綱辨證)'. In the 'Youkwonjeonggidae-ron("六元正紀大論")', Wang Bing of doesn't mention the concepts of 'Jungwun(中運)' that is seen in the original classic. In the new corrective edition, as the concepts of 'Jungwun, Dongcheonbu, Dongsehae and Taeulcheonbu(中運, 同天符, 同歲會, 太乙天符)' is appeared, Wang Bing seems to only use the concepts of 'Daewun, Juwun, and Gaekwun(大運, 主運, 客運)'. In the 'Jijinyodaeron("至眞要大論")', Wang Bing added detailed commentary to pathology and treatment doctrine by explaining the numerous appearances of 'Sebo, sufficiency, deficiency(歲步, 有餘, 不足)' and in the relation of 'victory-defeat(勝復)', he argued clearly that it is not mechanical estimation. (4) When we observe the Wang Bing's originality on the study of 'the theory of Doctrine on five elements' motion and six kinds of natural factors(運氣學說)', he emphasized 'The idea of Jeongindogi and Health preserving(全眞導氣${\cdot}$養生思想)' by adding 'Wang Bing's Commentary(王氷 注本)' of 'The seven great chapters("七篇大論")' and explained clearly 'The theory of Doctrine on five elements' motion and six kinds of natural factors(運氣學說)' and simpled and expanded the meaning of 'man, as a microcosm, is connected with the macrocosm(天人相應)' and with 'Atmosphere theory(大氣論)' also explained the meaning of 'rising and falling mechanism(升降氣機)'. In the sentence of 'By examining the pathology, take care of your health(審察病機 無失氣宜)'. he explained the meaning of pathology of 'heart-kidney-water-fire(心腎水火)' and suggested the doctrine and management of prescription. In the estimation and treatment, by suggesting 'asthenia and sthenia(虛實)' two method's estimation, 'contrary treatment(反治)' and treatment principals of 'falling heart fire tonifyng kidney water(降心火益腎水)', 'two class of chill and fever(寒熱二綱)' were demonstrated. There are 'inside and outside in the illness and so inner and outer in the treatment(病有中外 治有表囊)'. This sentence suggests concertedly. 'two class of superfies and interior(表囊二綱)' conforming to the position of disease. Therefore Wang Bing as an excellent theorist and introduced 'Cheoniin ideology(天眞思想)' as a clinician and realized the medical science. With these accomplishes mainly written in 'The theory of Doctrine on five elements' motion and six kinds of natural factors(運氣學說)' of 'The seven great chapters("七篇大論")', he interpreted the ancient medical scriptures and expanded the meaning of scriptures and conclusively contributed to the development of the study 'Korean Oriental Medicine(韓醫學)'.

  • PDF

Evaluating the Efficiency of the Device in Shielding Scattered Radiation during Treatment of Carcinoma of the Penis (음경암의 방사선치료 시 자체 제작한 Device의 산란선 차폐 효과에 대한 유용성 평가)

  • Gim, Yang-Soo;Lee, Sun-Young;Lim, Suk-Gun;Gwak, Geun-Tak;Pak, Ju-Gyeong;Lee, Seung-Hoon;Hwang, Ho-In;Cha, Seok-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: We evaluated the device that was created for maintaining the patient's setup and protecting the testicles from scattered radiation during treatment of carcinoma of the penis. Materials and Methods: The phantom testicles were made of vaseline cotton gauze and the device consisted of 5 mm of acryl box and 4 mm of lead shielding. $3{\times}3\;cm^2$, $4{\times}4\;cm^2$, $5{\times}5\;cm^2$, $6{\times}6\;cm^2$, $7{\times}7\;cm^2$ field sizes were used for this study and measurement was made at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field for 10 times with lead shielding and without the shielding respectively. 200 cGy was delivered using 6 MV photons. Results: The scatted radiation without lead shielding at 4, 5, 6, 7, 8, 10 cm from the lower edge of the field were 14.8-4.7 cGy with $3{\times}3\;cm^2$, 15.7-5.2 cGy with $4{\times}4\;cm^2$, 17.6-5.5 cGy with $5{\times}5\;cm^2$, 19.9-6.6 cGy with $6{\times}6\;cm^2$, 22.2-7.6 cGy with $7{\times}7\;cm^2$ and the measured dose without lead shielding were 7.1-2.6 cGy with $3{\times}3\;cm^2$, 8.9-3.6 cGy with $4{\times}4\;cm^2$, 12.3-4.8 cGy with $5{\times}5\;cm^2$, 14.6-5.0 cGy with $6{\times}6\;cm^2$ and 21.1~6.4 cGy with $7{\times}7\;cm^2$. As shown above, the scatted radiation decreased after using lead shielding. Depending of the range of field sizes, the resulting difference between without shielding values and with shielding values were: 7.8-1.1 cGy at 4 cm, 5.1-1.2 cGy at 5 cm, 3.8-1.1 cGy at 6 cm, 3.4-1.7 cGy at 7 cm, 2.8-1.7 cGy at 8 cm, 2.4-2.5 cGy at 9 cm and 2.1-1.8 cGy at 10 cm. In the situation as described above, the range in values depending on the distance was 7.8-1.1 cGy with $3{\times}3\;cm^2$, 6.9-1.6 cGy with $4{\times}4\;cm^2$, 5.3-0.8 cGy with $5{\times}5\;cm^2$, 5.3-1.5 cGy with $6{\times}6\;cm^2$ and 1.1-1.8 cGy with $7{\times}7\;cm^2$. Conclusion: Using the device we created to shield the testicles from scattered radiation during treatment of carcinoma of the penis, we have found that scattered radiation to the testicles is decreased by the phantom testicles, and by increasing the distance between the testicles and penis.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.