• Title/Summary/Keyword: measure distortion

Search Result 270, Processing Time 0.028 seconds

Error Analysis of the Image Measurement System (영상 측정 시스템의 오차 분석)

  • 김준희;유은이;사승윤;김광래;유봉환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.490-495
    • /
    • 1996
  • Though the increment of using computer vision system in modern industry, there are lots of difficulties to measure precisely because of measurement error distortion phenomenon. Among these reasons, the distortion of edge is dominant reason which is occurred by the blurred image. The blurred image is happened when camera can not discriminate its precise focus. To calibrate and generalize distortion phenomenon is important. Thus, we must fix the discrimination criteria which is collected by image recognition of precise focus. Also, radial distortion causes an inward or outward displacement of a given image point from its ideal location. This type of distortion is mainly caused by flawed radial curvature curve of the elements. Thus, we were analyzed the distortion in terms of the changed with lens magnification.

  • PDF

RELATION BETWEEN FRACTAL MEASURES AND CANTOR MEASURES

  • Baek, In-Soo
    • Communications of the Korean Mathematical Society
    • /
    • v.22 no.2
    • /
    • pp.241-246
    • /
    • 2007
  • We investigate the relation between Hausdorff(packing) measure and lower(packing) Cantor measure on a deranged Cantor set. If the infimum of some distortion of contraction ratios is positive, then Hausdorff(packing) measure and lower(packing) Cantor measure of a deranged Cantor set are equivalent except for some singular behavior for packing measure case. It is a generalization of already known result on the perturbed Cantor set.

Removal of Complexity Management in H.263 Codec for A/VDelivery Systems

  • Jalal, Ahmad;Kim, Sang-Wook
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.931-936
    • /
    • 2006
  • This paper presents different issues of the real-time compression algorithms without compromising the video quality in the distributed environment. The theme of this research is to manage the critical processing stages (speed, information lost, redundancy, distortion) having better encoded ratio, without the fluctuation of quantization scale by using IP configuration. In this paper, different techniques such as distortion measure with searching method cover the block phenomenon with motion estimation process while passing technique and floating measurement is configured by discrete cosine transform (DCT) to reduce computational complexity which is implemented in this video codec. While delay of bits in encoded buffer side especially in real-time state is being controlled to produce the video with high quality and maintenance a low buffering delay. Our results show the performance accuracy gain with better achievement in all the above processes in an encouraging mode.

  • PDF

Color image quantization considering distortion measure of local region block on RGB space (RGB 공간상의 국부 영역 블록의 왜곡척도를 고려한 칼라 영상 양자화)

  • 박양우;이응주;김경만;엄태억;하영호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.848-854
    • /
    • 1996
  • Many image display devices allow only a limited number of colors to be simultaneously displayed. in disphaying of natural color image using color palette, it is necessary to construct an optimal color palette and the optimal mapping of each pixed of the original image to a color from the palette. In this paper, we proposed the clustering algorithm using local region block centered one color cluster in the prequantized 3-D histogram. Cluster pairs which have the least distortion error are merged by considering distortion measure. The clustering process is continued until to obtain the desired number of colors. The same as the clustering process, original color value. The proposed algorithm incroporated with a spatial activity weighting value which is reflected sensitivity of HVS quantization errors in smoothing region. This method produces high quality display images and considerably reduces computation time.

  • PDF

STUDIES ON THE DISTORTION OF SOME DENTAL WAXES (치과용 왁스의 변형측정에 관한 연구)

  • Kim, Cheol-We
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.17-21
    • /
    • 1978
  • The object of this study was to measure of the distortion of various dental waxes under condition simulating clinical usage. Eleven commercial product (table) including the inlay and baseplate waxes were tested, and compared in the study. Test specimens were prepared $5{\times}5{\times}65mm$. split brass mold. Placed this rod wax specimens and the brass wax distortion test mold into the water bath and tested the distortion values for waxes at $35^{\circ}C,\;40^{\cric}C,\;45^{\circ}C\;and\;50^{\circ}C$. Measured the distortion as the difference between the final (Df) and original (Do) distance between the ends of the specimen. Recorded Df, Do and Df-Do (Distortion) to the nearest 0.5mm. A minimum of five specimens were tested for each material. The following conclusions may be drawn from this study. 1) It can be seen that, a significant wax distortion was obtained with the temperature of forming the pattern, and the length of time and the temperature at which it was stored. 2) It was found that, when the storage time was increased, the wax distortion was correspondingly increased. At the sametime, the higher the storage time was employed, the distortion was obviously much greater. 3) It can be observed that the higher the temperature at which the wax was manipulated, the less was the resulting distortion upon storage.

  • PDF

A Relevant Distortion Criterion for Interpolation of the Head-Related Transfer Functions (머리 전달 함수의 보간에 적합한 왜곡 척도)

  • Lee, Ki-Seung;Lee, Seok-Pil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.85-95
    • /
    • 2009
  • In the binaural synthesis environments, wide varieties of the head-related transfer functions (HRTFs) that have measured with a various direction would be desirable to obtain the accurate and various spatial sound images. To reduce the size' of HRTFs, interpolation has been often employed, where the HRTF for any direction is obtained by a limited number of the representative HRTFs. In this paper, we study on the distortion measures for interpolation, which has an important role in interpolation. With lhe various objective distortion metrics, the differences between the interpolated and the measured HRTFs were computed. These were then compared and analyzed with the results from the listening tests. From the results, the objective distortion measures were selected, that reflected the perceptual differences in spatial sound image. This measure was employed in a practical interpolation technique. We applied the proposed method to four kinds of an HRTF set, measured from three human heads and one mannequin. As a result, the Mel-frequency cepstral distortion was shown to be a good predictor for the differences in spatial sound location, when three HRTF measured from human, and the time-domain signal to distortion ratio revealed good prediction results for the entire four HRTF sets.

Polarization Distortion and Compensation of Circularly Polarized Emission from Chiral Metasurfaces

  • Yeonsoo Lim;In Cheol Seo;Young Chul Jun
    • Current Optics and Photonics
    • /
    • v.7 no.2
    • /
    • pp.147-156
    • /
    • 2023
  • Circularly polarized (CP) emission can be achieved by integrating emissive materials into chiral metasurfaces. Such CP light sources in integrated device platforms are desirable for important potential applications. However, the exact characterization of the polarization state in CP emission may include some errors because of the unwanted polarization distortion caused by optical components (e.g., beam splitter) in the optical setup. Here, we consider CP emission measurements from chiral metasurfaces and characterize the polarization distortion caused by the beam splitter. We first detail the procedures for the Stokes parameters and Mueller matrix measurements. Then, we directly measure the Mueller matrix of the beam splitter and retrieve the original polarization state of CP emission from our metasurface sample. Using the measured Mueller matrix of the beam splitter, we specifically identify what contributes to polarization distortion in CP emission. Our work may provide useful guidelines for the characterization and compensation of polarization distortion in general Stokes parameter measurements.

A Study on Distortion and Dose of Images in Mobile Radiography (이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구)

  • Song, Hyeon-Seok;Lim, Cheong-Hwan;Jung, Hong-Ryang;Kim, Jong-Seong;Kim, Yeong-Ran;Jeong, Sung-Hun
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.305-312
    • /
    • 2022
  • The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.

An Improved Fractal Color Image Decoding Based on Data Dependence and Vector Distortion Measure (데이터 의존성과 벡터왜곡척도를 이용한 개선된 프랙탈 칼라영상 복호화)

  • 서호찬;정태일;류권열;권기룡;문광석
    • Journal of Korea Multimedia Society
    • /
    • v.2 no.3
    • /
    • pp.289-296
    • /
    • 1999
  • In this paper, an improved fractal color image decoding method using the data dependence parts and the vector distortion measure is proposed. The vector distortion measure exploits the correlation between different color components. The pixel in RGB color space can be considered as a 30dimensional vector with elements of RGB components. The root mean square error(rms) in RGB color for similarity measure of two blocks R and R' was used. We assume that various parameter necessary in image decoding are stored in the transform table. If the parameter is referenced in decoding image, then decoding is performed by the recursive decoding method. If the parameter is not referenced in decoding image, then the parameters recognize as the data dependence parts and store its in the memory. Non-referenced parts can be decoded only one time, because its domain informations exist in the decoded parts by the recursive decoding method. Non-referenced parts are defined the data dependence parts. Image decoding method using data dependence classifies referenced parts and non-referenced parts using information of transform table. And the proposed method can be decoded only one time for R region decoding speed than Zhang & Po's method, since it is decreased the computational numbers by execution iterated contractive transformations for the referenced range only.

  • PDF