• Title/Summary/Keyword: mean phase angle

Search Result 116, Processing Time 0.026 seconds

An Experimental Study on the Drop Size of a Twin-Fluid Swirl Jet Nozzle (이유체 선회분사 노즐의 액적크기에 관한 실험적 연구)

  • Oh, J.H.;Kim, W.T.;Kang, S.J.;Rho, B.J.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 1996
  • This experimental study was to investigate spray angles and drop sizes in an external mixed twin-fluid swirl jet nozzle. Twin-fluid swirl jet nozzle with swirlers designed four swirl angles such as $0^{\circ},\;22.5^{\circ},\;45^{\circ},\;64.2^{\circ}$ was employed. A PDA system was utilized for the measurement of drop size and mean velocity. Water and air were used as the working fluids in this experiment. The mass flow rate of water was fixed as 0.03 kg/min, and air flow rates were controlled to have the air/liquid mass ratio from 1.0 to 6.0. As a result, swirl angle controlled to spray angles and drop sizes. It was found that swirl angle was increased with spray angle and with decreased SMD. However, the effect of swirl angle was reduced at large air/liquid mass ratio(Mr=6.0).

  • PDF

Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta (위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정)

  • Kim, Moon Sun;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.142-148
    • /
    • 2016
  • To evaluate the effect of flip angle on flow rate measurements obtained with phase contrast MRI according to the flip angle degree in ascending aorta and velocity encoding (VENC) was (150 m/s). 1.5T MRI in patients 17 (female: 8, male: 9, mean age $57.9{\pm}15.4$) as a target by applying a non-breath holding techniques to flip angle VENC (150 cm/s) in each of the ascending aorta was measured by changing $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$. Blood was obtained a peak velocity, average velocity, net forward volume, net forward volume/body surface area. Ascending aorta from average velocity (AV) measured the average value of the flip angle $20^{\circ}$ (9.87 cm/s), $30^{\circ}$ (9.6 cm/s) and $40^{\circ}$ (10.05 cm/s). Blood flow VENC in was blood flow change in flip angle change was high most blood flow measurement when the flip angle $30^{\circ}$ in VENC, crouching each blood flow is also proportional to the increases in the $20^{\circ}$ to $40^{\circ}$ and was increased, the deviation of the peak velocity and the average velocity is the smallest deviation from the flip angle $30^{\circ}$. Flip angle $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$ in peak velocity, average velocity, net forward volume, net forward volume/body surface area was no statistically significant difference (p > .05). Blood flow velocity and blood flow is measured by applying to adjust the flip angle accurately calculate the blood flow is important information for diagnosis and treatment of cardiovascular diseases, and can help in the examination on the blood flow measurement.

A Comparison Study of Cervical Flexion-Relaxation Ratio in the Normal and Forward Head Postures

  • Yeo, Sang-Seok;Kwon, Jung-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.6
    • /
    • pp.378-382
    • /
    • 2020
  • Purpose: This study aimed to examine the effects of forward head posture on the flexion-relaxation ratio (FRR) and muscle activity during sustained neck flexion and to investigate the correlation between craniovertebral angle and FRR. Methods: Nineteen subjects participated in this study and were allocated to a forward head posture (FHP) group or a non-forward head posture (NFHP) group. Craniovertebral angle (CVA) and FRR were measured in all subjects, and all participants performed a standardized cervical flexion-extension movement in two phases: Phase I, sustained cervical full flexion for 5s; and Phase II, cervical extension with the return to the starting position for 5s. The value of CVA has calculated three times, and the value of FRR was measured three times in order to obtain the mean value. Results: FRR values in the FHP and NFHP group were significantly different (p<0.05). Phase I was significantly different, but the Phase II was not significantly different between the FHP and NFHP group (p>0.05). There was a significant correlation between the muscle activity of Phase I and CVA (p<0.05). However, FRR and the muscle activity of the Phase II were not a significant correlation with the CVA (p>0.05). Conclusion: FHP increases the muscle activity of the cervical erector spinae during sustained neck flexion and reduces FRR, which can cause fatigue in the cervical erector spinae. In addition, for those with a smaller CVA, muscle activity of the cervical erector spinae is increased during sustained neck flexion, which can increase neck muscle tension.

A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle (낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구)

  • 김철주;강환국;김윤철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

Effect of the Swirler Angle and Aspect Ratio of Nozzle on the Mean Velocity and SMD of Twin Sprays (노즐의 스월러각과 형상비가 이중분무의 평균속도와 입경의 크기에 미치는 영향)

  • Kim, Young-Jin;Jung, Ji-Won;Choi, Gyoung-Min;Kim, Duck-Jool
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1459-1466
    • /
    • 2004
  • The purpose of this study is to investigate the effect of swirler angle and the aspect ratio of swirl chamber of nozzle on the characteristics of single and twin spray. The characteristics of sprays have been investigated by measuring the spray angle, droplet size and velocity. Visualization of spray was conducted to obtain the spray angle and breakup process. The spray characteristics such as droplet size and velocity were measured by Phase Doppler Anemometry(PDA). It was found that the spray angle was increased with increasing the swirler angle. For both sprays, the axial velocity and SMD were decreased with increasing the swirler angle. It was also shown that the axial velocity and SMD were decreased with increasing the aspect ratio of swirl chamber, but for the twin spray, the axial velocity and SMD were not influenced significantly by the changing the aspect ratio of swirl chamber. The effect of swirler angle on the spray characteristics was greater than the aspect ratio of swirl chamber for single spray. The nozzle pitch was one of the important factors affecting the spray characteristics of twin spray.

Sport biomechanical comparative analyses between general sporting shoe and functional walking shoe (보행용 전문 신발과 일반 운동화의 운동역학적 비교 분석)

  • Choi, Kyoo-Jeong;Kwon, Hee-Ja
    • Korean Journal of Applied Biomechanics
    • /
    • v.13 no.2
    • /
    • pp.161-173
    • /
    • 2003
  • This study was performed to investigate the kinematic and kinetic differences between functional walking shoe(FWS) and general sports shoe(GSS). The subjects for this study were 4 male adults who had the walking pattern of rearfoot strike with normal feet. The movement of one lower leg was measured using force platform and 3 video cameras while the subjects walked at the velocity of 2/1.5 m/s. The findings of this study were as follows 1. The angle of lower leg-ground and angle of knee with FWS was greater than with GSS at the moment of strike the floor and the moment of second peak ground reaction force. The decreasing rate of angle of ankle was smaller in FWS from the strike phase to the second peak ground reaction force. These mean upright walking and round walking along the shoe surface. 2. The maximal Increased angle of Achilles tendon and the minimal decreased angle of rearfoot were smaller in FWS very significantly(p<0.001). Thus FWS prevent the excessive pronation of ankle and have good of rear-foot control. 3. The vortical ground reaction force and the rate of it to the BW were smaller in FWS statistically(p<0.001). The loading rate was smaller in FWS, too, and thess represent the reduction of load on ankle joint and prevention of injuries on it.

Identifications of Reflex Muscle Activities and Joint Moments Triggered by Electrical Stimulation to Sole of the Foot during Lokomat Treadmill Walking

  • Kim, Yong-Chul
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.5
    • /
    • pp.344-350
    • /
    • 2010
  • The aim of this study was to investigate the characteristics of the flexion withdrawal reflex modulated during Lokomat treadmill walking in people with spinal cord injury. The influence of the limb position and movement were tested in 5 subjects with chronic spinal cord injury. EMG activities from tibialis anterior and moments of the hip joint elicited by the foot stimulation were examined during Lokomat treadmill walking. To trigger the flexion withdrawal reflex during Lokomat treadmill walking, a train of 10 stimulus pulses was applied at the skin of the medial arch. The TA EMG activity was modulated during gait phase and the largest TA reflex was obtained after heel-off and initial swing phase. During swing phase, TA EMG was 40.9% greater for the extended hip position (phase 6), compared with flexed hip position (phase 8). The measured reflex moment of the hip joint was also modulated during gait phase. In order to characterize the neural contribution of flexion reflex at the hip joint, we compared estimated moments consisted of the static and dynamic components with measured moment of the hip joint. The mean static gains of reflex hip moments for swing and stance phase are -0.1, -0.8, respectively. The mean dynamic gains of reflex hip moments are 0.25 for swing, 0.75 for stance phase. From this study, we postulate that the joint moment and muscle response of flexion withdrawal reflex have the phase-dependent modulation and linear relationship with hip angle and angular velocity for swing phase during Lokomat treadmill walking.

Kinematic Analysis on the Stabilization & Correction Effects of Riding Posture According to Rider's Skill Levels in Horse Back Riding (승마 숙련도에 따른 기승자세 교정효과의 운동학적 분석)

  • Ryew, Che-Cheong
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.83-94
    • /
    • 2012
  • The purpose of this study was to analyse the effect of posture correction & stabilization according to horse rider's(n=10) skill levels of novice(0wk), mid-skill(12wk) & skill(24wk) in walk & trot. First, Mean posture of 3 times experiments; Anterior & posterior leaning posture of trunk showed rather unstable according to progress of the stages of TD1, TO, TD2 phase, and also shoulder & elbow angle, which effects to the distance from bit to rein, showed unstable riding posture. There was close relationship between shoulder and elbow Angle in walk and hip, knee & ankle angle in trot. Second, Posture correction & stabilization according to riding skill levels; Anterior & posterior leaning posture of trunk did not show significant difference statistically but showed approaching tendency to trunk's vertical line and showed significant difference(p<.05) according to improvement of skill levels in walk & trot horse riding. Hip angle showed significant difference according to progress of the stages of TD1, TO, TD2 phase(p<.05) and showed tendency maintaining the larger thigh flexion according to improvement of skill levels in walk & trot. Knee angle showed more stable posture by maintaining the larger flexion between thigh and shank according to improvement of skill levels in walk & trot(p<.05). Ankle angle also showed tendency maintaining the larger plantar flexion of foot according to improvement of skill levels in walk & trot. When considering the above, regular horse riding program could be useful in posture correction & stabilization according to improvement of skill levels of novice(0wk), mid-skill(12wk) & skill(24wk) in walk & trot.

Relationship between the Impact Peak Force and Lower Extremity Kinematics during Treadmill Running

  • Ryu, Ji-Seon;Park, Sang-Kyoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.3
    • /
    • pp.159-164
    • /
    • 2018
  • Objective: The aims of this study were to determine the impact peak force and kinematic variables in running speed and investigate the relationship between them. Method: Thirty-nine male heel strike runners ($mean\;age=21.7{\pm}1.6y$, $mean\;mass=72.5{\pm}8.7kg$, $mean\;height=176.6{\pm}6.1cm$) were recruited in this investigation. The impact peak forces during treadmill running were assessed, and the kinematic variables were computed using three-dimensional data collected using eight infrared cameras (Oqus 300, Qualisys, Sweden). One-way analysis of variance ANOVAwas used to investigate the influence of the running speed on the parameters, and Pearson's partial correlation was used to investigate the relationship between the impact peak force and kinematic variables. Results: The running speed affected the impact peak force, stride length, stride frequency, and kinematic variables during the stride phase and the foot angle at heel contact; however, it did not affect the ankle and knee joint angles in the sagittal plane at heel contact. No significant correlation was noted between the impact peak force and kinematic variables in constantrunning speed. Conclusion: Increasing ankle and knee joint angles at heel contact may not be related to the mechanism behind reducing the impact peak force during treadmill running at constant speed.

Effect of Injector-driven Type on Spray Behavior and Fuel Atomization Characteristics (인젝터 구동 방식에 따른 분무 거동 및 분무 미립화 특성)

  • Park, Ji-Hong;Suh, Hyun-Kyu;Park, Sung-Wook;Kim, Jae-Wook;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • This study was performed to figure out spray behavior and fuel atomization characteristics of a piezo-driven injector and a solenoid-driven injector in the common-rail injection system under the same design parameters and test conditions. The process of spray injection was visualized by using the spray visualization system composed of a Nd:YAG laser and an ICCD camera. The atomization characteristics were investigated in terms of axial mean velocity, Sauter mean diameter(SMD) and droplet distributions obtained from a phase Doppler particle analyzer system. Compared with solenoid-driven injector, the piezo-driven injector has short injection delay and reaches quickly to the maximum injection value. Spray tip penetration shows some difference, however, spray angle of piezo-driven injector is wider than that of solenoid-driven injector. Sauter mean diameter of piezo-driven type injector is smaller than that of solenoid-driven type.