Browse > Article
http://dx.doi.org/10.4283/JKMS.2016.26.4.142

Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta  

Kim, Moon Sun (Department of Radiology, Seoul National University Hospital)
Kweon, Dae Cheol (Department of Radiological Science, College of Health Science, Shinhan University)
Abstract
To evaluate the effect of flip angle on flow rate measurements obtained with phase contrast MRI according to the flip angle degree in ascending aorta and velocity encoding (VENC) was (150 m/s). 1.5T MRI in patients 17 (female: 8, male: 9, mean age $57.9{\pm}15.4$) as a target by applying a non-breath holding techniques to flip angle VENC (150 cm/s) in each of the ascending aorta was measured by changing $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$. Blood was obtained a peak velocity, average velocity, net forward volume, net forward volume/body surface area. Ascending aorta from average velocity (AV) measured the average value of the flip angle $20^{\circ}$ (9.87 cm/s), $30^{\circ}$ (9.6 cm/s) and $40^{\circ}$ (10.05 cm/s). Blood flow VENC in was blood flow change in flip angle change was high most blood flow measurement when the flip angle $30^{\circ}$ in VENC, crouching each blood flow is also proportional to the increases in the $20^{\circ}$ to $40^{\circ}$ and was increased, the deviation of the peak velocity and the average velocity is the smallest deviation from the flip angle $30^{\circ}$. Flip angle $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$ in peak velocity, average velocity, net forward volume, net forward volume/body surface area was no statistically significant difference (p > .05). Blood flow velocity and blood flow is measured by applying to adjust the flip angle accurately calculate the blood flow is important information for diagnosis and treatment of cardiovascular diseases, and can help in the examination on the blood flow measurement.
Keywords
average velocity; flip angle; MRI; peak velocity; phase contrast; VENC;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 M. Romhild, J. G. Chris, and A. Max, Magn. Reson. Med. 41, 520 (1999).   DOI
2 C. M. Tsai, E. W. Olcott, and D. G. Nishimura, Magn. Reson. Med. 42, 682 (1999).   DOI
3 K. M. Lagerstrand, H. Lehmann, G. Starck, B. Vikhoff-Baaz, S. Ekholm, and E. Forssell-Aronsson, Magn. Reson. Med. 48, 883 (2002).   DOI
4 J. Lotz, C. Meier, A. Leppert, and M. Galanski, Radiographics 22, 651 (2002).   DOI
5 P. D. Gatehouse, J. Keegan, L. A. Crowe, S. Masood, R. H. Mohiaddin, K. F. Kreitner, and D. N. Firmin, Eur. Radiol. 15, 2172 (2005).   DOI
6 N. J. Pelc, F. G. Sommer, K. C. Li, T. J. Brosnan, R. J. Herfkens, and D. R. Enzmann, Magn. Reson. Q. 10, 125 (1994).
7 C. J. Bakker, M. Kouwenhoven, M. J. Hartkamp, R. M. Hoogeveen, and W. P. Mali, Magn. Reson. Imaging 13, 959 (1995).   DOI
8 H. Tanaka, N. Fujita, H. Takahashi, M. Sakai, T. Nagao, K. Murase, and H. Nakamura, J. Magn. Reson. Imaging 29, 1218 (2009).   DOI
9 Y. J. Choi and D. C. Kweon, J. Korean Magn. Soc. 26, 92 (2016).   DOI
10 M. Markl and J. Hennig, Magn. Reson. Imaging 19, 669 (2001).   DOI
11 L. S. Babiarz, J. M. Romero, E. K. Murphy, B. Brobeck, P. W. Schaefer, R. G. Gonzlez, and M. H. Lev, Am. J. Neuroradiol. 30, 761 (2009).   DOI
12 J. Alvarez Linera, J. Benito-Len, J. Escribano, J. Campollo, and R. Gesto, Am. J. Neuroradiol. 24, 1012 (2003).
13 R. H. Mohiaddin and D. J. Pennell, Cardiol. Clin. 16, 161 (1998).   DOI
14 S. D. Caruthers, S. J. Lin, P. Brown, M. P. Watkins, T. A. Williams, K. A. Lehr, and S. A. Wickline, Circulation 108, 2236 (2003).   DOI
15 Y. G. Jin, M. H. Choi, H. J. Goh, and D. K. Han, J. Magn. 21, 281 (2016).   DOI
16 J. B. Han and N. G. Choi, J. Radiol. Sci. Techol. 32, 101 (2009).
17 Y. S. Han, S. C. Lee, D. Y. Lee, J. W. Choi, J. W. Lee, and D. C. Kweon, J. Magn. 21, 115 (2016).   DOI
18 N. J. Pelc, F. G. Sommer, K. C. Li, T. J. Brosnan, R. J. Herfkens, and D. R. Enzmann, Magn. Reson. Q. 10, 125 (1994).
19 J. M. Sohns, J. T. Kowallick, A. A. Jeseph, K. D. Merbolt, D. Voit, M. Fasshauer, W. Stabb, J. Lotz, and C. Unterberg-Buchwald, Qunat. Imaging Med. Surg. 5, 685 (2015).