• Title/Summary/Keyword: maximal

Search Result 3,810, Processing Time 0.03 seconds

Studies on the Maximal Oxygen Intake of the Korean - Part I. Accuracy of the Measurement of Maximal Oxygen Intake - (한국인(韓國人) 청년남여(靑年男女)의 최대산소섭취량(最大酸素攝取量)에 관(關)한 연구(硏究) - 제(第) I 편(篇) 최대효소섭취양(最大酸素攝取量) 측정치(測定値)의 변리도(變異度)에 관(關)하여 -)

  • Lee, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.1 no.1
    • /
    • pp.83-90
    • /
    • 1967
  • In order to evaluate the accuracy of the measurement of maximal oxygen intake (MOI), the MOI in seven subjects was determined 3 to 4 times in each individual. Following a 10 minute warm-up on treadmill (4.3 km/hr with 9 degree grade), the subject was asked to run at a speed of 8.73 km/hr on treadmill for a period of 3 minutes at a given grade which was elevated in a step-wise manner from zero to the level of exhaustion. Following a 3 minute run, the subject was allowed to rest for a period of 3 to 5 minutes. During each period of running, several cardio-pulmonary functions were determined and the range of variability for each measurement was computed. The oxygen consumption during the maximal work load was taken as the MOI. The results may be summarized as follows: (1) The minute volume, the oxygen consumption and the heart rate increased linearly until the grade was elevated to 9 degree above which these values were leveled off. (2) The minute volume and the heart rate during maximal exorcise were $87.4{\pm}8.10\;1/min\;and\;187{\pm}3.7$ per minute, respectively. (3) The maximal oxygen intake which corresponds to the oxygen consumption during maximal exercise was averaged to 3.04 1/min. (4) The coefficient of variance for the maximal oxygen intake was 6.32% while the corresponding values for the minute volume and the heart rate during maximal exercise were 5.22 and 2. 14%, respectively.

  • PDF

The Effects of Stabilization on the Electromyographic Activities of the Masseter and Anterior Temporal Muscles during Maximal Clenching (안정교합장치가 교근 및 전측두근 활성에 미치는 영향)

  • Won-Ill Kang;Jae-Kap Choi
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 1991
  • The author studied the changes of electromyographic activities of the masseter and anterior temporal muscles during maximal clenching before and after stabilization splint wearing. It also studied the changes of the symmetry of the muscle activity during maximal clenching. For this study, 15-healthy-female-students were selected. The obtained results were as follows : The EMG activities of right and left anterior temporal muscles and right masseter muscle during maximal clenching immediately after wearing of the stabilization splint were not changed compared with before wearing of the stabilization splint. The EMG activities of right and left masseter and anterior temporal muscles during maximal clenching were significantly increased after 1 week and 4 week-use of the stabilization splint(p<0.01). The asymmetric indices of the EMG activities of right and left masseter and anterior temporal muscles during maximal clenching immediately after wearing of the stabilization splint were not changed compared with before wearing of the stabilization splint. The asymmetric indices of the EMG activities of right and left anterior temporal muscles during maximal clenching were significantly decreased after 1 week and 4 week use of the stabilization splint(p<0.01). and that of masseter muscles showed a decreased tendency but there were no significant differences(p>0.05).

  • PDF

Effect of Task Direction on the Maximal Pushing, Pulling, Twisting, and Grip Forces

  • Yoon, Jangwhon
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.5
    • /
    • pp.413-423
    • /
    • 2016
  • Objective:The aims of this study are to understand the effects of task (pushing, pulling, and clockwise and counter clockwise twisting) direction on the maximal output and their grip forces and to explore the relationship between the maximal output and the grip forces. Background: Knowing the normative maximal grip force is not enough to design a good hand tool. The industrial designers should understand the required grip forces in various motions toward a specific direction to make an effective and efficient hand tool. Method: Eighteen healthy volunteers participated in the series of isometric maximal output force tests. A custom-made force measuring equipment collected the output and the grip forces for three seconds. Force measurements along the vertical, coronal and sagittal axes were randomly repeated three times. Results: The pulling was strongest and the pushing was weakest in all directions. The effect of motion on the output forces varied in different directions. The corresponding grip force increased in the order of pushing, pulling, clockwise twisting, and counter clockwise twisting in all directions. The maximal output and their grip forces were highly correlated but the relationship was affected by motion and direction. The regression coefficient was greatest in pulling and smallest in clockwise twisting. Conclusion: The effect of motion on the output forces varied in different directions. The maximal output and their grip forces were correlated but the relationship was affected by motion and direction. Application: Findings of this study can be valuable information for industrial designers to develop more productive hand tools and work stations to help preventing the musculoskeletal disorders at work.

The Pulmonary Function and Heart Rate Recovery Response of Smoker and Nonsmoker in Males Aged 20s after Graded Maximal Exercise (최대부하운동 후 20대 남성 흡연자와 비흡연자의 폐기능과 심박수 회복 반응)

  • Kim, Eun-Jung
    • Journal of Korean Physical Therapy Science
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Purpose : The purpose of this study was to investigate the response of pulmonary function and heart rate recovery of smoker and nonsmoker in males aged 20s after graded maximal exercise. Method : The subjects were composed of smoker group (n=12) and nonsmoker group (n=12) in males aged 20s. Each groups completed an graded maximal exercise with Bruce protocol and were assessed on the pulmonary function(forced vital capacity : FVC, forced expiratory volume-one second : FEV1, FEV1/FVC) and heart rate. Result : The results were as follows: First, heart rate in the measurement point was a statistically significant difference for smoker and non-smoker group after maximal exercise, but FVC, FEV1, FEV1/FVC was no difference. Second, FEV1/FVC between smoker and nonsmoker group was a statistically significant difference after maximal exercise, but FVC, FEV1, heart rate was no difference. Conclusion : The results of this study is that smoking is negative effects on FEV1/FVC of pulmonary function in males aged 20s after maximal exercise.

  • PDF

ON THE STRUCTURES OF CLASS SEMIGROUPS OF QUADRATIC NON-MAXIMAL ORDERS

  • KIM, YONG TAE
    • Honam Mathematical Journal
    • /
    • v.26 no.3
    • /
    • pp.247-256
    • /
    • 2004
  • Buchmann and Williams[1] proposed a key exchange system making use of the properties of the maximal order of an imaginary quadratic field. $H{\ddot{u}}hnlein$ et al. [6,7] also introduced a cryptosystem with trapdoor decryption in the class group of the non-maximal imaginary quadratic order with prime conductor q. Their common techniques are based on the properties of the invertible ideals of the maximal or non-maximal orders respectively. Kim and Moon [8], however, proposed a key-exchange system and a public-key encryption scheme, based on the class semigroups of imaginary quadratic non-maximal orders. In Kim and Moon[8]'s cryptosystem, a non-invertible ideal is chosen as a generator of key-exchange ststem and their secret key is some characteristic value of the ideal on the basis of Zanardo et al.[9]'s quantity for ideal equivalence. In this paper we propose the methods for finding the non-invertible ideals corresponding to non-primitive quadratic forms and clarify the structure of the class semigroup of non-maximal order as finitely disjoint union of groups with some quantities correctly. And then we correct the misconceptions of Zanardo et al.[9] and analyze Kim and Moon[8]'s cryptosystem.

  • PDF

CURVES WITH MAXIMAL RANK, BUT NOT ACM, WITH VERY HIGH GENERA IN PROJECTIVE SPACES

  • Ballico, Edoardo
    • Journal of the Korean Mathematical Society
    • /
    • v.56 no.5
    • /
    • pp.1355-1370
    • /
    • 2019
  • A curve $X{\subset}\mathbb{P}^r$ has maximal rank if for each $t{\in}\mathbb{N}$ the restriction map $H^0(\mathcal{O}_{\mathbb{P}r}(t)){\rightarrow}H^0(\mathcal{O}_X(t))$ is either injective or surjective. We show that for all integers $d{\geq}r+1$ there are maximal rank, but not arithmetically Cohen-Macaulay, smooth curves $X{\subset}\mathbb{P}^r$ with degree d and genus roughly $d^2/2r$, contrary to the case r = 3, where it was proved that their genus growths at most like $d^{3/2}$ (A. Dolcetti). Nevertheless there is a sector of large genera g, roughly between $d^2/(2r+2)$ and $d^2/2r$, where we prove the existence of smooth curves (even aCM ones) with degree d and genus g, but the only integral and non-degenerate maximal rank curves with degree d and arithmetic genus g are the aCM ones. For some (d, g, r) with high g we prove the existence of reducible non-degenerate maximal rank and non aCM curves $X{\subset}\mathbb{P}^r$ with degree d and arithmetic genus g, while (d, g, r) is not realized by non-degenerate maximal rank and non aCM integral curves.